#  Broan L250EL Exhaust Fan Specifications

ENERGY STAR PD #2405558 · In-line (single-port) · Qualified 2022-12-09

Verified Specification Summary

Certified by EPA ENERGY STAR, Broan L250EL delivers 230 CFM free-air (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 3.9 CFM/W efficacy, clearing residential IRC M1505 sizing up to 230 sq ft (8-ft height) or 204 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan L250EL Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 230 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 3.9 CFM/W (#876/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 59.0 W (21.5 kWh/yr)

- **Duct & Tier**: 8 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan L250EL vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan L250EL (EPA filing PD #2405558) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 230 CFM (#40 of 1,145 certified models) via a 8 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 8 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Broan maintains 207 active ENERGY STAR blowers; L250EL (series: LIGHT COMMERCIAL) (PD #2405558) gained qualification on 2022-12-09. Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 59.0 watts, about 21.5 kWh/yr (~$3.44/yr at $0.16/kWh) for 1 hr/day shower timers or 516.8 kWh/yr (~$82.69/yr) continuously. Closest competing matches include Dayton 5AE72A (240.0 CFM) and Greenheck SP-A200 (240.0 CFM).

## Why does rigid 8 in. diameter ducting protect Broan L250EL airflow?

Connecting Broan L250EL through rigid 8 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Broan L250EL performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Broan L250EL lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan (207 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | L250EL / LIGHT COMMERCIAL | PD ID 2405558 (Qualified 2022-12-09) |
| **Duct Connection** | 8 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (230 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Broan L250EL?

Calculated coverage metrics translate Broan L250EL airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Broan L250EL

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 230 sq ft | 1 CFM/sq ft @ 230 CFM |
| Tall Bath (9-ft Ceiling) | Up to 204 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 180 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 21.5 kWh/yr (~$3.44/yr) | 59.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 516.8 kWh/yr (~$82.69/yr) | 59.0 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Broan L250EL?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Dayton 5AE72A**](https://siematic-charleston.com/ventilation-fans/dayton-5ae72a/) | 240 / N/A CFM | 1.4 sones | 4.3 CFM/W | 8 x 8 in. rectangular |
| [**Greenheck SP-A200**](https://siematic-charleston.com/ventilation-fans/greenheck-sp-a200/) | 240 / 224 CFM | 1.4 sones | 4.3 CFM/W | 8 x 8 in. rectangular |
| [**Dayton 6WZN6**](https://siematic-charleston.com/ventilation-fans/dayton-6wzn6/) | 213 / 204 CFM | Unpublished | 3.9 CFM/W | 8 x 8 in. rectangular |
| [**Greenheck CSP-A200**](https://siematic-charleston.com/ventilation-fans/greenheck-csp-a200/) | 213 / 204 CFM | Unpublished | 3.9 CFM/W | 8 x 6 in. rectangular |
| [**Broan L200E**](https://siematic-charleston.com/ventilation-fans/broan-l200e/) | 240 / 205.9 CFM | Unpublished | 4.7 CFM/W | 8 in. diameter |

## Does Broan L250EL match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Broan L250EL percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Broan L250EL fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan L250EL.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 180 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Recommended when:** Moisture load fits 230 CFM net static output
- **Target scenario:** Collar pairs with 8 in. diameter duct straight outdoors

## Which homeowner questions come up most for Broan L250EL?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Broan L250EL.

### Does running Broan L250EL continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Broan L250EL draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Broan L250EL pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan L250EL's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan L250EL?

Broan L250EL features a 8 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan L250EL's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan L250EL's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Broan L250EL code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan L250EL clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Broan L250EL?

Do not force Broan L250EL into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Broan L250EL retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Broan L250EL produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 8 in. diameter metal duct transitions.

### Will Broan L250EL disturb adjacent bedrooms during night use?

Acoustic measurement places Broan L250EL at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

## Where can you explore more benchmarks around Broan L250EL?

Use the related reference pages and estimators below to cross-check Broan L250EL against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Dayton 6WZN6 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/dayton-6wzn6/)
- [Greenheck CSP-A200 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/greenheck-csp-a200/)
- [Broan L200E Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-l200e/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)