title: "Broan LP80 Bath Fan (80 CFM, 1.0 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/broan-lp80-2248890/
description: "ENERGY STAR specs for Broan LP80: 80 CFM, 1.0 sones (#265 of 607), 3.7 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Broan LP80 Exhaust Fan Specifications

ENERGY STAR PD #2248890 · Bathroom/Utility Room · Qualified 2015-10-01

Verified Specification Summary

Rated for 80 CFM open-air (65.6 CFM at 0.25 in. w.g.), Broan LP80 registers #265 of 607 in quietness (1.0 sones) and delivers 3.7 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 65 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan LP80 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 65.6 CFM

- **Noise @ 0.1"**: 1.0 sones (#265/607)

- **Efficacy Rank**: 3.7 CFM/W (#987/1,145)

- **Static Retention**: 82.0% @ 0.25"

- **Motor Draw**: 21.6 W (7.9 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan LP80 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 65.6 CFM at 0.25 in. w.g. (82.0% retention, 5.7 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #2248890 verifies LP80 (series: N/A) under Broan (207 listed models, qualified 2015-10-01). Lighting kit: No. At 3.7 CFM/W (#987 of 1,145, below median tier among 1,145 rated models; more efficient than 11.3% of rated models, 1.0 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 21.6 watts, about 7.9 kWh/yr (~$1.26/yr at $0.16/kWh) for 1 hr/day shower timers or 189.2 kWh/yr (~$30.27/yr) continuously. Closest competing matches include Nutone LPN80=LP80HwithLPN80F (80.0 CFM) and Air King AK80H (80.0 CFM).

## How does Broan LP80 acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Broan LP80 (1.0 sones).

## How do flex elbows choke Broan LP80 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Broan LP80 moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Broan LP80 meet residential exhaust fan code specs?

Inspect Broan LP80 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan (207 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | LP80 / N/A | PD ID 2248890 (Qualified 2015-10-01) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (65.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (1.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Which bathroom duties match Broan LP80 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Broan LP80 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Broan LP80

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 65 sq ft | 1 CFM/sq ft @ 65.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 58 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.9 kWh/yr (~$1.26/yr) | 21.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 189.2 kWh/yr (~$30.27/yr) | 21.6 W x 8,760 hrs / 1,000 |

## Which competing models share Broan LP80 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Nutone LPN80=LP80HwithLPN80F**](https://siematic-charleston.com/ventilation-fans/nutone-lpn80-lp80hwithlpn80f-2341169/) | 80 / 65.6 CFM | 1.0 sones (Same) | 3.7 CFM/W | 4 in. diameter |
| [**Air King AK80H**](https://siematic-charleston.com/ventilation-fans/air-king-ak80h/) | 80 / 71.4 CFM | 1.0 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| [**Air King AK80LS1**](https://siematic-charleston.com/ventilation-fans/air-king-ak80ls1/) | 80 / 71.4 CFM | 1.0 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| [**Air King FR80**](https://siematic-charleston.com/ventilation-fans/air-king-fr80/) | 80 / 71.4 CFM | 1.0 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| [**Air King FR80H**](https://siematic-charleston.com/ventilation-fans/air-king-fr80h/) | 80 / 71.4 CFM | 1.0 sones (Same) | 3.8 CFM/W | 4 in. diameter |

## How much airflow margin does Broan LP80 give your bath?

Run a quick local room-volume check for Broan LP80 by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Broan LP80 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan LP80 for your remodel.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Strong scenario:** Bathroom floor <= 65 sq ft with 8-ft ceilings (58 sq ft at 9-ft height)
- **Best application:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What should homeowners verify first about Broan LP80?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Broan LP80.

### Who should NOT install Broan LP80 in a bathroom remodel?

Avoid specifying Broan LP80 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut Broan LP80 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan LP80 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does Broan LP80 occupy in EPA filings?

With 1.0 sones at 0.1 in. w.g., Broan LP80 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.

### How many kWh per year does Broan LP80 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Broan LP80 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Broan LP80 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan LP80's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan LP80?

Broan LP80 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan LP80's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan LP80's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Broan LP80 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan LP80 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

## Which GradeMark tools pair best with Broan LP80?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Broan LP80.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan LP80=LP80HwithLP80F Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-lp80-lp80hwithlp80f-2248912/)
- [Canarm CP80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/canarm-cp80/)
- [Broan EZ80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ez80-2248924/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)