title: "Broan LP80=LP80HwithLP80F Bath Fan (70 CFM, 1.1 Sone)"
url: https://siematic-charleston.com/ventilation-fans/broan-lp80-lp80hwithlp80f/
description: "ENERGY STAR specs for Broan LP80=LP80HwithLP80F: 70 CFM, 1.1 sones (#357 of 607), 3.4 CFM/W, 3 in. diameter and 5 closest peer fans."
---

#  Broan LP80=LP80HwithLP80F Exhaust Fan Specifications

ENERGY STAR PD #2248911 · Bathroom/Utility Room · Qualified 2015-10-01

Verified Specification Summary

Tested under HVI protocols, the Broan LP80=LP80HwithLP80F exhaust unit achieves 70 CFM at 0.1 in. w.g. (60.5 CFM at 0.25 in. w.g.), registers #357 of 607 in quietness (1.1 sones) and delivers 3.4 CFM/W efficacy, covering standard baths up to 60 sq ft on a 3 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan LP80=LP80HwithLP80F Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 70 / 60.5 CFM

- **Noise @ 0.1"**: 1.1 sones (#357/607)

- **Efficacy Rank**: 3.4 CFM/W (#1,060/1,145)

- **Static Retention**: 86.4% @ 0.25"

- **Motor Draw**: 20.6 W (7.5 kWh/yr)

- **Duct & Tier**: 3 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan LP80=LP80HwithLP80F vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.1 sones (#357 of 607 rated models, 0.10 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 60.5 CFM out of 70 CFM (86.4% retention, 1.3 pts lower retention than the 87.7% median). Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Broan registers 207 certified models, with SKU LP80=LP80HwithLP80F (series: N/A) (PD #2248911) certified since 2015-10-01. Lighting kit: No. At 3.4 CFM/W (#1,060 of 1,145, below median tier among 1,145 rated models; more efficient than 6.0% of rated models, 1.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.6 watts, about 7.5 kWh/yr (~$1.20/yr at $0.16/kWh) for 1 hr/day shower timers or 180.5 kWh/yr (~$28.88/yr) continuously. Closest competing matches include HomeWerks Worldwide 7105-10 (70.0 CFM) and HomeWerks Worldwide 7105-10-MB (70.0 CFM).

## Where do Broan LP80=LP80HwithLP80F sones rank across EPA ENERGY STAR fans?

Comparing Broan LP80=LP80HwithLP80F (1.1 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves Broan LP80=LP80HwithLP80F CFM output?

Short straight 3 in. diameter duct paths retain up to ~82% of open-air capacity on Broan LP80=LP80HwithLP80F, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Broan LP80=LP80HwithLP80F measure up on airflow and noise ratings?

Each row below breaks down Broan LP80=LP80HwithLP80F certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan (207 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | LP80=LP80HwithLP80F / N/A | PD ID 2248911 (Qualified 2015-10-01) |
| **Duct Connection** | 3 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (60.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.1 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect Broan LP80=LP80HwithLP80F CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Broan LP80=LP80HwithLP80F

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 60 sq ft | 1 CFM/sq ft @ 60.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 53 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.5 kWh/yr (~$1.20/yr) | 20.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 180.5 kWh/yr (~$28.88/yr) | 20.6 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Broan LP80=LP80HwithLP80F?

Compare Broan LP80=LP80HwithLP80F side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**HomeWerks Worldwide 7105-10**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7105-10/) | 70 / 55.7 CFM | 1.0 sones (-0.10) | 3.4 CFM/W | 4 in. diameter |
| [**HomeWerks Worldwide 7105-10-MB**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7105-10-mb/) | 70 / 55.7 CFM | 1.0 sones (-0.10) | 3.4 CFM/W | 4 in. diameter |
| [**Nektra 33003851**](https://siematic-charleston.com/ventilation-fans/nektra-33003851/) | 70 / 55.7 CFM | 1.0 sones (-0.10) | 3.4 CFM/W | 4 in. diameter |
| [**Tuscany 7105-11-M**](https://siematic-charleston.com/ventilation-fans/tuscany-7105-11-m/) | 70 / 55.7 CFM | 1.0 sones (-0.10) | 3.4 CFM/W | 4 in. diameter |
| [**Commercial Electric 7132-12-CE**](https://siematic-charleston.com/ventilation-fans/commercial-electric-7132-12-ce/) | 80 / 57.1 CFM | 1.1 sones (Same) | 3.3 CFM/W | 4 in. diameter |

## Can you size Broan LP80=LP80HwithLP80F for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan LP80=LP80HwithLP80F verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Broan LP80=LP80HwithLP80F in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Broan LP80=LP80HwithLP80F for residential use.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 60.5 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Ideal fit:** Target comfort around 1.1 sones up to 60 sq ft
- **Primary match:** Paired with rigid galvanized 3 in. diameter transition

## How do federal and code standards apply to Broan LP80=LP80HwithLP80F?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan LP80=LP80HwithLP80F.

### Why check Broan LP80=LP80HwithLP80F CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Broan LP80=LP80HwithLP80F registers unlisted 0.25 in. w.g. backpressure figures, making rigid 3 in. diameter duct runs vital.

### How does Broan LP80=LP80HwithLP80F sound output compare to noisy contractor-grade fans?

Rated at 1.1 sones, Broan LP80=LP80HwithLP80F produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Broan LP80=LP80HwithLP80F?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Broan LP80=LP80HwithLP80F pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan LP80=LP80HwithLP80F's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan LP80=LP80HwithLP80F?

Broan LP80=LP80HwithLP80F features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan LP80=LP80HwithLP80F's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan LP80=LP80HwithLP80F's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Broan LP80=LP80HwithLP80F satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Broan LP80=LP80HwithLP80F clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Broan LP80=LP80HwithLP80F undersized or poorly matched for a bath renovation?

Skip Broan LP80=LP80HwithLP80F if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

## What neighboring pages and tools support Broan LP80=LP80HwithLP80F?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Broan LP80=LP80HwithLP80F.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Revent RVL50 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvl50/)
- [Revent RVLH50 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvlh50/)
- [Broan LP80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-lp80/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)