#  Broan MTR1303BLS Exhaust Fan Specifications

ENERGY STAR PD #3629816 · Range Hood · Qualified 2024-09-13

Verified Specification Summary

Certified by EPA ENERGY STAR, Broan MTR1303BLS delivers 150 CFM free-air (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 4.6 CFM/W efficacy, clearing residential IRC M1505 sizing up to 150 sq ft (8-ft height) or 133 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan MTR1303BLS Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 150 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.6 CFM/W (#578/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 32.6 W (11.9 kWh/yr)

- **Duct & Tier**: 7 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan MTR1303BLS vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan MTR1303BLS (EPA filing PD #3629816) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.

Free-discharge delivery reaches 150 CFM (#104 of 1,145 certified models) via a 7 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 7 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Broan registers 207 certified models, with SKU MTR1303BLS (series: RANGE HOOD) (PD #3629816) certified since 2024-09-13. Lighting kit: Yes. At 4.6 CFM/W (#578 of 1,145, below median tier among 1,145 rated models; more efficient than 44.9% of rated models, 0.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 32.6 watts, about 11.9 kWh/yr (~$1.90/yr at $0.16/kWh) for 1 hr/day shower timers or 285.6 kWh/yr (~$45.70/yr) continuously. Closest competing matches include Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM) and Loren Cook Company GC-242 (142.0 CFM).

## Why does rigid 7 in. diameter ducting protect Broan MTR1303BLS airflow?

Connecting Broan MTR1303BLS through rigid 7 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Broan MTR1303BLS performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Broan MTR1303BLS lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan (207 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | MTR1303BLS / RANGE HOOD | PD ID 3629816 (Qualified 2024-09-13) |
| **Duct Connection** | 7 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (150 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What room sizes and annual power draw fit Broan MTR1303BLS?

Calculated coverage metrics translate Broan MTR1303BLS airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Broan MTR1303BLS

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 150 sq ft | 1 CFM/sq ft @ 150 CFM |
| Tall Bath (9-ft Ceiling) | Up to 133 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 100 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 11.9 kWh/yr (~$1.90/yr) | 32.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 285.6 kWh/yr (~$45.70/yr) | 32.6 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Broan MTR1303BLS?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Tech Drive TD-BF-24L-5CCT(BL)**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-24l-5cct-bl/) | 150 / 138.2 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Loren Cook Company GC-242**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gc-242/) | 142 / 112 CFM | 1.7 sones | 5.3 CFM/W | 4.5 x 6 in. rectangular |
| [**Broan QT150LE**](https://siematic-charleston.com/ventilation-fans/broan-qt150le/) | 150 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Nutone QTN130LE1**](https://siematic-charleston.com/ventilation-fans/nutone-qtn130le1/) | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Broan ALT4306SS**](https://siematic-charleston.com/ventilation-fans/broan-alt4306ss/) | 160 / N/A CFM | 1.5 sones | 3.2 CFM/W | 7 in. diameter |

## Does Broan MTR1303BLS match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Broan MTR1303BLS percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Broan MTR1303BLS suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan MTR1303BLS for your remodel.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 100 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Strong scenario:** Moisture load fits 150 CFM net static output
- **Best application:** Collar pairs with 7 in. diameter duct straight outdoors

## Which homeowner questions come up most for Broan MTR1303BLS?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Broan MTR1303BLS.

### How many kWh per year does Broan MTR1303BLS add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Broan MTR1303BLS averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Broan MTR1303BLS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan MTR1303BLS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan MTR1303BLS?

Broan MTR1303BLS features a 7 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan MTR1303BLS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan MTR1303BLS's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Broan MTR1303BLS pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan MTR1303BLS easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install Broan MTR1303BLS in a bathroom remodel?

Avoid specifying Broan MTR1303BLS in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut Broan MTR1303BLS airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan MTR1303BLS achieves unlisted 0.25 in. w.g. backpressure figures; matching a 7 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does Broan MTR1303BLS occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Broan MTR1303BLS produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

## Where can you explore more benchmarks around Broan MTR1303BLS?

Use the related reference pages and estimators below to cross-check Broan MTR1303BLS against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan MTR1303SS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-mtr1303ss/)
- [Broan MTR1303WW Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-mtr1303ww/)
- [Broan MTR1303BL Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-mtr1303bl/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)