title: "Broan MTR1303WW Bath Fan (150 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/broan-mtr1303ww/
description: "ENERGY STAR specs for Broan MTR1303WW: 150 CFM, 4.6 CFM/W, 7 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes, and."
---

#  Broan MTR1303WW Exhaust Fan Specifications

ENERGY STAR PD #3629818 · Range Hood · Qualified 2024-09-13

Verified Specification Summary

Rated for 150 CFM open-air (unpublished 0.25 in. w.g. output), Broan MTR1303WW omits a published 0.1-inch sone rating and delivers 4.6 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 150 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan MTR1303WW Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 150 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.6 CFM/W (#578/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 32.6 W (11.9 kWh/yr)

- **Duct & Tier**: 7 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan MTR1303WW vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan MTR1303WW (EPA filing PD #3629818) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.

Free-discharge delivery reaches 150 CFM (#104 of 1,145 certified models) via a 7 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 7 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Broan registers 207 certified models, with SKU MTR1303WW (series: RANGE HOOD) (PD #3629818) certified since 2024-09-13. Lighting kit: Yes. At 4.6 CFM/W (#578 of 1,145, below median tier among 1,145 rated models; more efficient than 44.9% of rated models, 0.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 32.6 watts, about 11.9 kWh/yr (~$1.90/yr at $0.16/kWh) for 1 hr/day shower timers or 285.6 kWh/yr (~$45.70/yr) continuously. Closest competing matches include Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM) and Loren Cook Company GC-242 (142.0 CFM).

## How do flex elbows choke Broan MTR1303WW at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 7 in. diameter metal pipe keeps Broan MTR1303WW moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Broan MTR1303WW meet residential exhaust fan code specs?

Inspect Broan MTR1303WW mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan (207 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | MTR1303WW / RANGE HOOD | PD ID 3629818 (Qualified 2024-09-13) |
| **Duct Connection** | 7 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (150 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## Which bathroom duties match Broan MTR1303WW airflow output?

Annual electricity figures and room square-footage ceilings below reflect Broan MTR1303WW tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Broan MTR1303WW

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 150 sq ft | 1 CFM/sq ft @ 150 CFM |
| Tall Bath (9-ft Ceiling) | Up to 133 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 100 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 11.9 kWh/yr (~$1.90/yr) | 32.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 285.6 kWh/yr (~$45.70/yr) | 32.6 W x 8,760 hrs / 1,000 |

## Which competing models share Broan MTR1303WW airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Tech Drive TD-BF-24L-5CCT(BL)**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-24l-5cct-bl/) | 150 / 138.2 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Loren Cook Company GC-242**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gc-242/) | 142 / 112 CFM | 1.7 sones | 5.3 CFM/W | 4.5 x 6 in. rectangular |
| [**Broan QT150LE**](https://siematic-charleston.com/ventilation-fans/broan-qt150le/) | 150 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Nutone QTN130LE1**](https://siematic-charleston.com/ventilation-fans/nutone-qtn130le1/) | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Broan ALT4306SS**](https://siematic-charleston.com/ventilation-fans/broan-alt4306ss/) | 160 / N/A CFM | 1.5 sones | 3.2 CFM/W | 7 in. diameter |

## How much airflow margin does Broan MTR1303WW give your bath?

Run a quick local room-volume check for Broan MTR1303WW by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Broan MTR1303WW?

Match Broan MTR1303WW directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 100 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Best for:** Bathroom floor <= 150 sq ft with 8-ft ceilings (133 sq ft at 9-ft height)
- **Optimal use:** Exterior run uses smooth rigid metal matched to 7 in. diameter

## What should homeowners verify first about Broan MTR1303WW?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Broan MTR1303WW.

### What bathroom square footage can Broan MTR1303WW ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Broan MTR1303WW covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does Broan MTR1303WW run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Broan MTR1303WW.

### What happens to Broan MTR1303WW CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Broan MTR1303WW moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 7 in. diameter collar.

### Where does Broan MTR1303WW sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Broan MTR1303WW produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does Broan MTR1303WW cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Broan MTR1303WW 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Broan MTR1303WW pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan MTR1303WW's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan MTR1303WW?

Broan MTR1303WW features a 7 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan MTR1303WW's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan MTR1303WW's safe coverage footprint from 50 sq ft to 44 sq ft.

## Which GradeMark tools pair best with Broan MTR1303WW?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Broan MTR1303WW.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan MTR1363SS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-mtr1363ss/)
- [Broan MTR2303SS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-mtr2303ss/)
- [Broan MTR1303SS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-mtr1303ss/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)