title: "Broan-Nutone 688E = 1667H with 1688EF Bath Fan (50 CFM, 2.0"
url: https://siematic-charleston.com/ventilation-fans/broan-nutone-688e-1667h-with-1688ef/
description: "ENERGY STAR specs for Broan-Nutone 688E = 1667H with 1688EF: 50 CFM, 2.0 sones (#522 of 607), 3.0 CFM/W, 3 in. diameter and 5 closest peer fans."
---

#  Broan-Nutone 688E = 1667H with 1688EF Exhaust Fan Specifications

ENERGY STAR PD #3892116 · Bathroom/Utility Room · Qualified 2024-12-20

Verified Specification Summary

Homeowners specifying Broan-Nutone 688E = 1667H with 1688EF gain 50 CFM at 0.1 in. w.g. (36.5 CFM at 0.25 in. w.g.) where it registers #522 of 607 in quietness (2.0 sones) and delivers 3.0 CFM/W efficacy, venting bathrooms up to 36 sq ft cleanly through 3 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone 688E = 1667H with 1688EF Exhaust Fan before installation.

- **Airflow @ 0.1" / 0.25"**: 50 / 36.5 CFM

- **Noise @ 0.1"**: 2.0 sones (#522/607)

- **Efficacy Rank**: 3.0 CFM/W (#1,105/1,145)

- **Static Retention**: 73.0% @ 0.25"

- **Motor Draw**: 16.7 W (6.1 kWh/yr)

- **Duct & Tier**: 3 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan-Nutone 688E = 1667H with 1688EF vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 50 CFM open-air to 36.5 CFM at 0.25 in. w.g. (73.0% retention, 14.7 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Broan-Nutone maintains 48 active ENERGY STAR blowers; 688E = 1667H with 1688EF (series: D-Can Energy Star Fans) (PD #3892116) gained qualification on 2024-12-20. Lighting kit: No. At 3.0 CFM/W (#1,105 of 1,145, below median tier among 1,145 rated models; more efficient than 1.2% of rated models, 1.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 16.7 watts, about 6.1 kWh/yr (~$0.98/yr at $0.16/kWh) for 1 hr/day shower timers or 146.3 kWh/yr (~$23.41/yr) continuously. Closest competing matches include Broan 688ESL (50.0 CFM) and Cyclone CE50 (50.0 CFM).

## What acoustic percentile does Broan-Nutone 688E = 1667H with 1688EF occupy among 1,145 bath blowers?

Inspect how Broan-Nutone 688E = 1667H with 1688EF positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

## Which exterior damper path suits Broan-Nutone 688E = 1667H with 1688EF best?

Exterior roof or wall damper termination paired with insulated 3 in. diameter metal pipe prevents condensation buildup around Broan-Nutone 688E = 1667H with 1688EF housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Broan-Nutone 688E = 1667H with 1688EF acoustic and static metrics stand?

Compare Broan-Nutone 688E = 1667H with 1688EF published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan-Nutone (48 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 688E = 1667H with 1688EF / D-Can Energy Star Fans | PD ID 3892116 (Qualified 2024-12-20) |
| **Duct Connection** | 3 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | CONTINUOUS ONLY (36.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (2.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can Broan-Nutone 688E = 1667H with 1688EF handle taller ceilings or walk-in tub steam?

Evaluate how Broan-Nutone 688E = 1667H with 1688EF scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Broan-Nutone 688E = 1667H with 1688EF

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 36 sq ft | 1 CFM/sq ft @ 36.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 32 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.1 kWh/yr (~$0.98/yr) | 16.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 146.3 kWh/yr (~$23.41/yr) | 16.7 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Broan-Nutone 688E = 1667H with 1688EF?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan 688ESL**](https://siematic-charleston.com/ventilation-fans/broan-688esl/) | 50 / 36.5 CFM | 2.0 sones (Same) | 3.0 CFM/W | 3 in. diameter |
| [**Cyclone CE50**](https://siematic-charleston.com/ventilation-fans/cyclone-ce50/) | 50 / 41 CFM | 2.0 sones (Same) | 3.1 CFM/W | 3 in. diameter |
| [**Wintek 7140-50-PS**](https://siematic-charleston.com/ventilation-fans/wintek-7140-50-ps/) | 50 / 41 CFM | 2.0 sones (Same) | 3.1 CFM/W | 3 in. diameter |
| [**Broan-Nutone 688E**](https://siematic-charleston.com/ventilation-fans/broan-nutone-688e/) | 50 / 36.5 CFM | 2.0 sones (Same) | 3.0 CFM/W | 3 in. diameter |
| [**Broan-Nutone 688E = 1667EH with 1688EF**](https://siematic-charleston.com/ventilation-fans/broan-nutone-688e-1667eh-with-1688ef/) | 50 / 36.5 CFM | 2.0 sones (Same) | 3.0 CFM/W | 3 in. diameter |

## Is Broan-Nutone 688E = 1667H with 1688EF sized right for your shower or tub room?

Check whether Broan-Nutone 688E = 1667H with 1688EF clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Broan-Nutone 688E = 1667H with 1688EF?

Match Broan-Nutone 688E = 1667H with 1688EF directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Best for:** Supplementary continuous trickle ventilation
- **Optimal use:** Collar pairs with 3 in. diameter duct straight outdoors

## Which code checks and cost facts matter for Broan-Nutone 688E = 1667H with 1688EF?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Broan-Nutone 688E = 1667H with 1688EF.

### Where does Broan-Nutone 688E = 1667H with 1688EF run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Broan-Nutone 688E = 1667H with 1688EF.

### What happens to Broan-Nutone 688E = 1667H with 1688EF CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Broan-Nutone 688E = 1667H with 1688EF moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 3 in. diameter collar.

### Where does Broan-Nutone 688E = 1667H with 1688EF sit on acoustic comfort for senior homeowners?

Measuring 2.0 sones, Broan-Nutone 688E = 1667H with 1688EF produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does Broan-Nutone 688E = 1667H with 1688EF cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Broan-Nutone 688E = 1667H with 1688EF 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Broan-Nutone 688E = 1667H with 1688EF pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone 688E = 1667H with 1688EF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan-Nutone 688E = 1667H with 1688EF?

Broan-Nutone 688E = 1667H with 1688EF features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan-Nutone 688E = 1667H with 1688EF's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone 688E = 1667H with 1688EF's safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can Broan-Nutone 688E = 1667H with 1688EF ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone 688E = 1667H with 1688EF covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

## How can you cross-check Broan-Nutone 688E = 1667H with 1688EF against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Broan-Nutone 688E = 1667H with 1688EF.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan-Nutone 688ES Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-nutone-688es/)
- [Broan-Nutone 688ES = 1667EH with 1688ESF Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-nutone-688es-1667eh-with-1688esf/)
- [Broan-Nutone 688E = 1667EH with 1688EF Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-nutone-688e-1667eh-with-1688ef/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)