#  Broan-Nutone 688E Exhaust Fan Specifications

ENERGY STAR PD #3892112 · Bathroom/Utility Room · Qualified 2024-12-20

Verified Specification Summary

Homeowners specifying Broan-Nutone 688E gain 50 CFM at 0.1 in. w.g. (36.5 CFM at 0.25 in. w.g.) where it registers #522 of 607 in quietness (2.0 sones) and delivers 3.0 CFM/W efficacy, venting bathrooms up to 36 sq ft cleanly through 3 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone 688E Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 50 / 36.5 CFM

- **Noise @ 0.1"**: 2.0 sones (#522/607)

- **Efficacy Rank**: 3.0 CFM/W (#1,105/1,145)

- **Static Retention**: 73.0% @ 0.25"

- **Motor Draw**: 16.7 W (6.1 kWh/yr)

- **Duct & Tier**: 3 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan-Nutone 688E vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 50 CFM open-air to 36.5 CFM at 0.25 in. w.g. (73.0% retention, 14.7 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Broan-Nutone registers 48 certified models, with SKU 688E (series: D-Can Energy Star Fans) (PD #3892112) certified since 2024-12-20. Lighting kit: No. At 3.0 CFM/W (#1,105 of 1,145, below median tier among 1,145 rated models; more efficient than 1.2% of rated models, 1.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 16.7 watts, about 6.1 kWh/yr (~$0.98/yr at $0.16/kWh) for 1 hr/day shower timers or 146.3 kWh/yr (~$23.41/yr) continuously. Closest competing matches include Broan 688ESL (50.0 CFM) and Cyclone CE50 (50.0 CFM).

## What acoustic percentile does Broan-Nutone 688E occupy among 1,145 bath blowers?

Inspect how Broan-Nutone 688E positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

## Which exterior damper path suits Broan-Nutone 688E best?

Exterior roof or wall damper termination paired with insulated 3 in. diameter metal pipe prevents condensation buildup around Broan-Nutone 688E housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Broan-Nutone 688E acoustic and static metrics stand?

Compare Broan-Nutone 688E published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan-Nutone (48 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 688E / D-Can Energy Star Fans | PD ID 3892112 (Qualified 2024-12-20) |
| **Duct Connection** | 3 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | CONTINUOUS ONLY (36.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (2.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can Broan-Nutone 688E handle taller ceilings or walk-in tub steam?

Evaluate how Broan-Nutone 688E scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Broan-Nutone 688E

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 36 sq ft | 1 CFM/sq ft @ 36.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 32 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.1 kWh/yr (~$0.98/yr) | 16.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 146.3 kWh/yr (~$23.41/yr) | 16.7 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Broan-Nutone 688E?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan 688ESL**](https://siematic-charleston.com/ventilation-fans/broan-688esl/) | 50 / 36.5 CFM | 2.0 sones (Same) | 3.0 CFM/W | 3 in. diameter |
| [**Cyclone CE50**](https://siematic-charleston.com/ventilation-fans/cyclone-ce50/) | 50 / 41 CFM | 2.0 sones (Same) | 3.1 CFM/W | 3 in. diameter |
| [**Wintek 7140-50-PS**](https://siematic-charleston.com/ventilation-fans/wintek-7140-50-ps/) | 50 / 41 CFM | 2.0 sones (Same) | 3.1 CFM/W | 3 in. diameter |
| [**Broan-Nutone 688E = 1667EH with 1688EF**](https://siematic-charleston.com/ventilation-fans/broan-nutone-688e-1667eh-with-1688ef/) | 50 / 36.5 CFM | 2.0 sones (Same) | 3.0 CFM/W | 3 in. diameter |
| [**Broan-Nutone 688E = 1667H with 1688EF**](https://siematic-charleston.com/ventilation-fans/broan-nutone-688e-1667h-with-1688ef/) | 50 / 36.5 CFM | 2.0 sones (Same) | 3.0 CFM/W | 3 in. diameter |

## Is Broan-Nutone 688E sized right for your shower or tub room?

Check whether Broan-Nutone 688E clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Broan-Nutone 688E on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Broan-Nutone 688E carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Choose this if:** Supplementary continuous trickle ventilation
- **Works well for:** Collar pairs with 3 in. diameter duct straight outdoors

## Which code checks and cost facts matter for Broan-Nutone 688E?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Broan-Nutone 688E.

### Will long attic ducting choke Broan-Nutone 688E capacity?

Because static drag at 0.25 in. w.g. lowers Broan-Nutone 688E from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 3 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is Broan-Nutone 688E compared with a standard 3.0 sone builder fan?

Tested at 2.0 sones, Broan-Nutone 688E produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Broan-Nutone 688E consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Broan-Nutone 688E draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Broan-Nutone 688E pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone 688E's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan-Nutone 688E?

Broan-Nutone 688E features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan-Nutone 688E's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone 688E's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Broan-Nutone 688E score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone 688E delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Broan-Nutone 688E?

Rule out Broan-Nutone 688E when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

## How can you cross-check Broan-Nutone 688E against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Broan-Nutone 688E.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan-Nutone 688E = 1667EH with 1688EF Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-nutone-688e-1667eh-with-1688ef/)
- [Broan-Nutone 688E = 1667H with 1688EF Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-nutone-688e-1667h-with-1688ef/)
- [Broan-Nutone 6884ES = 6884H with 1688ESF Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-nutone-6884es-6884h-with-1688esf/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)