---
title: "Broan-Nutone 6964NE = 6884EH with 1696NEF Bath Fan (50 CFM,"
url: https://siematic-charleston.com/ventilation-fans/broan-nutone-6964ne-6884eh-with-1696nef/
description: "ENERGY STAR specs for Broan-Nutone 6964NE = 6884EH with 1696NEF: 50 CFM, 2.0 sones (#522 of 607), 2.9 CFM/W, 4 in. diameter and 5 closest peer fans."
---

#  Broan-Nutone 6964NE = 6884EH with 1696NEF Exhaust Fan Specifications

ENERGY STAR PD #3890958 · Bathroom/Utility Room · Qualified 2024-12-13

Verified Specification Summary

Tested under HVI protocols, the Broan-Nutone 6964NE = 6884EH with 1696NEF exhaust unit achieves 50 CFM at 0.1 in. w.g. (38.2 CFM at 0.25 in. w.g.), registers #522 of 607 in quietness (2.0 sones) and delivers 2.9 CFM/W efficacy, covering standard baths up to 38 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone 6964NE = 6884EH with 1696NEF Exhaust Fan before installation.

- **Airflow @ 0.1" / 0.25"**: 50 / 38.2 CFM

- **Noise @ 0.1"**: 2.0 sones (#522/607)

- **Efficacy Rank**: 2.9 CFM/W (#1,132/1,145)

- **Static Retention**: 76.4% @ 0.25"

- **Motor Draw**: 17.2 W (6.3 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan-Nutone 6964NE = 6884EH with 1696NEF vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 50 CFM open-air to 38.2 CFM at 0.25 in. w.g. (76.4% retention, 11.3 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Broan-Nutone maintains 48 active ENERGY STAR blowers; 6964NE = 6884EH with 1696NEF (series: ECONOMY) (PD #3890958) gained qualification on 2024-12-13. Lighting kit: No. At 2.9 CFM/W (#1,132 of 1,145, tied with 13 other rated models at 2.9 CFM/W, 1.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 17.2 watts, about 6.3 kWh/yr (~$1.01/yr at $0.16/kWh) for 1 hr/day shower timers or 150.7 kWh/yr (~$24.11/yr) continuously. Closest competing matches include Broan 688ESL (50.0 CFM) and Cyclone CE50 (50.0 CFM).

## Where do Broan-Nutone 6964NE = 6884EH with 1696NEF sones rank across EPA ENERGY STAR fans?

Comparing Broan-Nutone 6964NE = 6884EH with 1696NEF (2.0 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves Broan-Nutone 6964NE = 6884EH with 1696NEF CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Broan-Nutone 6964NE = 6884EH with 1696NEF, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Broan-Nutone 6964NE = 6884EH with 1696NEF measure up on airflow and noise ratings?

Each row below breaks down Broan-Nutone 6964NE = 6884EH with 1696NEF certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan-Nutone (48 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 6964NE = 6884EH with 1696NEF / ECONOMY | PD ID 3890958 (Qualified 2024-12-13) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | CONTINUOUS ONLY (38.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (2.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect Broan-Nutone 6964NE = 6884EH with 1696NEF CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Broan-Nutone 6964NE = 6884EH with 1696NEF

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 38 sq ft | 1 CFM/sq ft @ 38.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 33 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.3 kWh/yr (~$1.01/yr) | 17.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 150.7 kWh/yr (~$24.11/yr) | 17.2 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Broan-Nutone 6964NE = 6884EH with 1696NEF?

Compare Broan-Nutone 6964NE = 6884EH with 1696NEF side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan 688ESL**](https://siematic-charleston.com/ventilation-fans/broan-688esl/) | 50 / 36.5 CFM | 2.0 sones (Same) | 3.0 CFM/W | 3 in. diameter |
| [**Cyclone CE50**](https://siematic-charleston.com/ventilation-fans/cyclone-ce50/) | 50 / 41 CFM | 2.0 sones (Same) | 3.1 CFM/W | 3 in. diameter |
| [**Wintek 7140-50-PS**](https://siematic-charleston.com/ventilation-fans/wintek-7140-50-ps/) | 50 / 41 CFM | 2.0 sones (Same) | 3.1 CFM/W | 3 in. diameter |
| [**Broan-Nutone 6884E = 6884EH with 1688EF**](https://siematic-charleston.com/ventilation-fans/broan-nutone-6884e-6884eh-with-1688ef/) | 50 / 38.2 CFM | 2.0 sones (Same) | 2.9 CFM/W | 4 in. diameter |
| [**Broan-Nutone 6884E = 6884H with 1688EF**](https://siematic-charleston.com/ventilation-fans/broan-nutone-6884e-6884h-with-1688ef/) | 50 / 38.2 CFM | 2.0 sones (Same) | 2.9 CFM/W | 4 in. diameter |

## Can you size Broan-Nutone 6964NE = 6884EH with 1696NEF for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan-Nutone 6964NE = 6884EH with 1696NEF verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Broan-Nutone 6964NE = 6884EH with 1696NEF suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan-Nutone 6964NE = 6884EH with 1696NEF for your remodel.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 38.2 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Strong scenario:** Target comfort around 2.0 sones up to 38 sq ft
- **Best application:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to Broan-Nutone 6964NE = 6884EH with 1696NEF?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan-Nutone 6964NE = 6884EH with 1696NEF.

### Does duct resistance cut Broan-Nutone 6964NE = 6884EH with 1696NEF airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan-Nutone 6964NE = 6884EH with 1696NEF achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does Broan-Nutone 6964NE = 6884EH with 1696NEF occupy in EPA filings?

With 2.0 sones at 0.1 in. w.g., Broan-Nutone 6964NE = 6884EH with 1696NEF produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

### How many kWh per year does Broan-Nutone 6964NE = 6884EH with 1696NEF add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Broan-Nutone 6964NE = 6884EH with 1696NEF averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Broan-Nutone 6964NE = 6884EH with 1696NEF pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone 6964NE = 6884EH with 1696NEF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan-Nutone 6964NE = 6884EH with 1696NEF?

Broan-Nutone 6964NE = 6884EH with 1696NEF features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan-Nutone 6964NE = 6884EH with 1696NEF's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone 6964NE = 6884EH with 1696NEF's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Broan-Nutone 6964NE = 6884EH with 1696NEF pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone 6964NE = 6884EH with 1696NEF easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install Broan-Nutone 6964NE = 6884EH with 1696NEF in a bathroom remodel?

Avoid specifying Broan-Nutone 6964NE = 6884EH with 1696NEF in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

## What neighboring pages and tools support Broan-Nutone 6964NE = 6884EH with 1696NEF?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Broan-Nutone 6964NE = 6884EH with 1696NEF.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan-Nutone 6964NE = 6884H with 1696NEF Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-nutone-6964ne-6884h-with-1696nef/)
- [Broan-Nutone 696NE Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-nutone-696ne/)
- [Broan-Nutone 688ES = 1667H with 1688ESF Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-nutone-688es-1667h-with-1688esf/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
