title: "Broan-Nutone BENL5 Bath Fan (50 CFM, 0.7 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/broan-nutone-benl5/
description: "ENERGY STAR specs for Broan-Nutone BENL5: 50 CFM, 0.7 sones (#135 of 607), 3.4 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency."
---

#  Broan-Nutone BENL5 Exhaust Fan Specifications

ENERGY STAR PD #3554015 · Bathroom/Utility Room · Qualified 2024-05-03

Verified Specification Summary

Tested under HVI protocols, the Broan-Nutone BENL5 exhaust unit achieves 50 CFM at 0.1 in. w.g. (49.5 CFM at 0.25 in. w.g.), registers #135 of 607 in quietness (0.7 sones) and delivers 3.4 CFM/W efficacy, covering standard baths up to 49 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone BENL5 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 50 / 49.5 CFM

- **Noise @ 0.1"**: 0.7 sones (#135/607)

- **Efficacy Rank**: 3.4 CFM/W (#1,060/1,145)

- **Static Retention**: 99.0% @ 0.25"

- **Motor Draw**: 14.7 W (5.4 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan-Nutone BENL5 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 49.5 CFM out of 50 CFM (99.0% retention, 11.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Broan-Nutone BENL5 (series: ROOMSIDE) under PD #3554015 (48 models registered, 2024-05-03). Lighting kit: Yes. At 3.4 CFM/W (#1,060 of 1,145, below median tier among 1,145 rated models; more efficient than 6.0% of rated models, 1.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 14.7 watts, about 5.4 kWh/yr (~$0.86/yr at $0.16/kWh) for 1 hr/day shower timers or 128.8 kWh/yr (~$20.61/yr) continuously. Closest competing matches include HomeWerks Worldwide 7141-50 (50.0 CFM) and HomeWerks Worldwide 7141-50-G4 (50.0 CFM).

## Where do Broan-Nutone BENL5 sones rank across EPA ENERGY STAR fans?

Comparing Broan-Nutone BENL5 (0.7 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves Broan-Nutone BENL5 CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Broan-Nutone BENL5, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Broan-Nutone BENL5 measure up on airflow and noise ratings?

Each row below breaks down Broan-Nutone BENL5 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan-Nutone (48 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | BENL5 / ROOMSIDE | PD ID 3554015 (Qualified 2024-05-03) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | CONTINUOUS ONLY (49.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.7 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How does ceiling height affect Broan-Nutone BENL5 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Broan-Nutone BENL5

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 49 sq ft | 1 CFM/sq ft @ 49.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 44 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.4 kWh/yr (~$0.86/yr) | 14.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 128.8 kWh/yr (~$20.61/yr) | 14.7 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Broan-Nutone BENL5?

Compare Broan-Nutone BENL5 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**HomeWerks Worldwide 7141-50**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7141-50/) | 50 / 36.3 CFM | 0.7 sones (Same) | 3.0 CFM/W | 4 in. diameter |
| [**HomeWerks Worldwide 7141-50-G4**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7141-50-g4/) | 50 / 35.9 CFM | 0.7 sones (Same) | 2.9 CFM/W | 4 in. diameter |
| [**Air King FR50**](https://siematic-charleston.com/ventilation-fans/air-king-fr50/) | 50 / 42 CFM | 0.6 sones (-0.10) | 3.5 CFM/W | 4 in. diameter |
| [**Air King BFQ50**](https://siematic-charleston.com/ventilation-fans/air-king-bfq50/) | 50 / 37.4 CFM | 0.6 sones (-0.10) | 2.9 CFM/W | 4 in. diameter |
| [**Air King WM50**](https://siematic-charleston.com/ventilation-fans/air-king-wm50/) | 50 / 37.4 CFM | 0.6 sones (-0.10) | 2.9 CFM/W | 4 in. diameter |

## Can you size Broan-Nutone BENL5 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan-Nutone BENL5 verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Broan-Nutone BENL5 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Broan-Nutone BENL5 for residential use.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 49.5 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Ideal fit:** Target comfort around 0.7 sones up to 49 sq ft
- **Primary match:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to Broan-Nutone BENL5?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan-Nutone BENL5.

### Why check Broan-Nutone BENL5 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Broan-Nutone BENL5 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

### How does Broan-Nutone BENL5 sound output compare to noisy contractor-grade fans?

Rated at 0.7 sones, Broan-Nutone BENL5 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Broan-Nutone BENL5?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Broan-Nutone BENL5 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone BENL5's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan-Nutone BENL5?

Broan-Nutone BENL5 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan-Nutone BENL5's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone BENL5's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Broan-Nutone BENL5 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone BENL5 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Broan-Nutone BENL5 undersized or poorly matched for a bath renovation?

Skip Broan-Nutone BENL5 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

## What neighboring pages and tools support Broan-Nutone BENL5?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Broan-Nutone BENL5.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [HomeWerks Worldwide 7141-50 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7141-50/)
- [HomeWerks Worldwide 7141-50-G4 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7141-50-g4/)
- [S&P PCLP80XP Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/s-p-pclp80xp/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)