title: "Broan-Nutone LP510RS Bath Fan (100 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/broan-nutone-lp510rs/
description: "ENERGY STAR specs for Broan-Nutone LP510RS: 100 CFM, 9.1 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes."
---

#  Broan-Nutone LP510RS Exhaust Fan Specifications

ENERGY STAR PD #2839029 · Bathroom/Utility Room · Qualified 2023-11-17

Verified Specification Summary

Tested under HVI protocols, the Broan-Nutone LP510RS exhaust unit achieves 100 CFM at 0.1 in. w.g. (97 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 9.1 CFM/W efficacy, covering standard baths up to 97 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone LP510RS Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 97 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 9.1 CFM/W (#292/1,145)

- **Static Retention**: 97.0% @ 0.25"

- **Motor Draw**: 11.0 W (4.0 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan-Nutone LP510RS vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan-Nutone LP510RS (EPA filing PD #2839029) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 97 CFM out of 100 CFM (97.0% retention, 9.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Broan-Nutone maintains 48 active ENERGY STAR blowers; LP510RS (series: LP) (PD #2839029) gained qualification on 2023-11-17. Lighting kit: No. At 9.1 CFM/W (#292 of 1,145, top 25.9% of 1,145 rated models, more efficient than 74.1% of rated models, 4.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.0 watts, about 4.0 kWh/yr (~$0.64/yr at $0.16/kWh) for 1 hr/day shower timers or 96.4 kWh/yr (~$15.42/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Delta 100HS (100.0 CFM).

## What attic duct routing preserves Broan-Nutone LP510RS CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Broan-Nutone LP510RS, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Broan-Nutone LP510RS measure up on airflow and noise ratings?

Each row below breaks down Broan-Nutone LP510RS certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan-Nutone (48 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | LP510RS / LP | PD ID 2839029 (Qualified 2023-11-17) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (97 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect Broan-Nutone LP510RS CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Broan-Nutone LP510RS

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 97 sq ft | 1 CFM/sq ft @ 97 CFM |
| Tall Bath (9-ft Ceiling) | Up to 86 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 47 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.0 kWh/yr (~$0.64/yr) | 11.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 96.4 kWh/yr (~$15.42/yr) | 11.0 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Broan-Nutone LP510RS?

Compare Broan-Nutone LP510RS side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Delta GBR100LED-DECOR**](https://siematic-charleston.com/ventilation-fans/delta-gbr100led-decor/) | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| [**Delta 100HS**](https://siematic-charleston.com/ventilation-fans/delta-100hs/) | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| [**Delta ITG100ELED**](https://siematic-charleston.com/ventilation-fans/delta-itg100eled/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Delta ITG100RLED**](https://siematic-charleston.com/ventilation-fans/delta-itg100rled/) | 100 / 89.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## Can you size Broan-Nutone LP510RS for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan-Nutone LP510RS verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Broan-Nutone LP510RS fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan-Nutone LP510RS.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 97 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Recommended when:** Target comfort around ENERGY STAR sones up to 97 sq ft
- **Target scenario:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to Broan-Nutone LP510RS?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan-Nutone LP510RS.

### Will Broan-Nutone LP510RS disturb adjacent bedrooms during night use?

Acoustic measurement places Broan-Nutone LP510RS at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

### Does running Broan-Nutone LP510RS continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Broan-Nutone LP510RS draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Broan-Nutone LP510RS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone LP510RS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan-Nutone LP510RS?

Broan-Nutone LP510RS features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan-Nutone LP510RS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone LP510RS's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Broan-Nutone LP510RS code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone LP510RS clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Broan-Nutone LP510RS?

Do not force Broan-Nutone LP510RS into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Broan-Nutone LP510RS retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Broan-Nutone LP510RS produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

## What neighboring pages and tools support Broan-Nutone LP510RS?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Broan-Nutone LP510RS.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan-Nutone LP510RS2 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-nutone-lp510rs2/)
- [Broan-Nutone LP510RSL Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-nutone-lp510rsl/)
- [Broan-Nutone LP510RR Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-nutone-lp510rr/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)