title: "Broan-Nutone PCPE811K = PCPE811H with PCPE811KF Bath Fan"
url: https://siematic-charleston.com/ventilation-fans/broan-nutone-pcpe811k-pcpe811h-with-pcpe811kf/
description: "ENERGY STAR specs for Broan-Nutone PCPE811K = PCPE811H with PCPE811KF: 110 CFM, 4.2 CFM/W, 4 in. diameter and 5 closest peer fans."
---

#  Broan-Nutone PCPE811K = PCPE811H with PCPE811KF Exhaust Fan Specifications

ENERGY STAR PD #4481305 · Bathroom/Utility Room · Qualified 2025-07-25

Verified Specification Summary

In EPA dataset 8dv7-nngq, Broan-Nutone PCPE811K = PCPE811H with PCPE811KF tests at 110 CFM free discharge (94.1 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 4.2 CFM/W efficacy, meeting residential IRC M1505 sizing up to 94 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone PCPE811K = PCPE811H with PCPE811KF before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 94.1 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.2 CFM/W (#774/1,145)

- **Static Retention**: 85.5% @ 0.25"

- **Motor Draw**: 26.2 W (9.6 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan-Nutone PCPE811K = PCPE811H with PCPE811KF vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan-Nutone PCPE811K = PCPE811H with PCPE811KF (EPA filing PD #4481305) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 94.1 CFM out of 110 CFM (85.5% retention, 2.2 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Broan-Nutone maintains 48 active ENERGY STAR blowers; PCPE811K = PCPE811H with PCPE811KF (series: FLEX SERIES) (PD #4481305) gained qualification on 2025-07-25. Lighting kit: No. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.2 watts, about 9.6 kWh/yr (~$1.54/yr at $0.16/kWh) for 1 hr/day shower timers or 229.5 kWh/yr (~$36.72/yr) continuously. Closest competing matches include Broan AER110LTMB (110.0 CFM) and Broan AER110LTW (110.0 CFM).

## Why avoid unvented attic termination with Broan-Nutone PCPE811K = PCPE811H with PCPE811KF?

Under ASHRAE 62.2 best practice, Broan-Nutone PCPE811K = PCPE811H with PCPE811KF needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Broan-Nutone PCPE811K = PCPE811H with PCPE811KF?

Before cutting ceiling drywall or sizing attic transitions for Broan-Nutone PCPE811K = PCPE811H with PCPE811KF, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan-Nutone (48 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | PCPE811K = PCPE811H with PCPE811KF / FLEX SERIES | PD ID 4481305 (Qualified 2025-07-25) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (94.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit Broan-Nutone PCPE811K = PCPE811H with PCPE811KF?

Bathroom ventilation sizing below maps Broan-Nutone PCPE811K = PCPE811H with PCPE811KF motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Broan-Nutone PCPE811K = PCPE811H with PCPE811KF

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 94 sq ft | 1 CFM/sq ft @ 94.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 83 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 44 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.6 kWh/yr (~$1.54/yr) | 26.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 229.5 kWh/yr (~$36.72/yr) | 26.2 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Broan-Nutone PCPE811K = PCPE811H with PCPE811KF in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Broan-Nutone PCPE811K = PCPE811H with PCPE811KF.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan AER110LTMB**](https://siematic-charleston.com/ventilation-fans/broan-aer110ltmb/) | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**Broan AER110LTW**](https://siematic-charleston.com/ventilation-fans/broan-aer110ltw/) | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**Nutone AER110SLW**](https://siematic-charleston.com/ventilation-fans/nutone-aer110slw/) | 110 / 89.5 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**Nutone AERN110LTK**](https://siematic-charleston.com/ventilation-fans/nutone-aern110ltk/) | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**Nutone AERN110LTW**](https://siematic-charleston.com/ventilation-fans/nutone-aern110ltw/) | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |

## What percentage of room demand does Broan-Nutone PCPE811K = PCPE811H with PCPE811KF cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Broan-Nutone PCPE811K = PCPE811H with PCPE811KF tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Broan-Nutone PCPE811K = PCPE811H with PCPE fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan-Nutone PCPE811K = PCPE811H with PCPE.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 94.1 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Recommended when:** Target comfort around ENERGY STAR sones up to 94 sq ft
- **Target scenario:** Paired with rigid galvanized 4 in. diameter transition

## Where do official rules set limits for Broan-Nutone PCPE811K = PCPE811H with PCPE811KF?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Broan-Nutone PCPE811K = PCPE811H with PCPE811KF.

### Does running Broan-Nutone PCPE811K = PCPE811H with PCPE811KF continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Broan-Nutone PCPE811K = PCPE811H with PCPE811KF draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Broan-Nutone PCPE811K = PCPE811H with PCPE811KF pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone PCPE811K = PCPE811H with PCPE811KF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan-Nutone PCPE811K = PCPE811H with PCPE811KF?

Broan-Nutone PCPE811K = PCPE811H with PCPE811KF features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan-Nutone PCPE811K = PCPE811H with PCPE811KF's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone PCPE811K = PCPE811H with PCPE811KF's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Broan-Nutone PCPE811K = PCPE811H with PCPE811KF code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone PCPE811K = PCPE811H with PCPE811KF clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Broan-Nutone PCPE811K = PCPE811H with PCPE811KF?

Do not force Broan-Nutone PCPE811K = PCPE811H with PCPE811KF into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Broan-Nutone PCPE811K = PCPE811H with PCPE811KF retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Broan-Nutone PCPE811K = PCPE811H with PCPE811KF produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

### Will Broan-Nutone PCPE811K = PCPE811H with PCPE811KF disturb adjacent bedrooms during night use?

Acoustic measurement places Broan-Nutone PCPE811K = PCPE811H with PCPE811KF at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

## What related resources expand on Broan-Nutone PCPE811K = PCPE811H with PCPE811KF?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan-Nutone PCPER811 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-nutone-pcper811/)
- [Broan-Nutone PCPER811 = PCPE811H with PCPER811F Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-nutone-pcper811-pcpe811h-with-pcper811f/)
- [Broan-Nutone PCPE811K Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-nutone-pcpe811k/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)