title: "Broan-Nutone PCPER811 = PCPE811H with PCPER811F Bath Fan"
url: https://siematic-charleston.com/ventilation-fans/broan-nutone-pcper811-pcpe811h-with-pcper811f/
description: "ENERGY STAR specs for Broan-Nutone PCPER811 = PCPE811H with PCPER811F: 110 CFM, 4.2 CFM/W, 4 in. diameter and 5 closest peer fans."
---

#  Broan-Nutone PCPER811 = PCPE811H with PCPER811F Exhaust Fan Specifications

ENERGY STAR PD #4481304 · Bathroom/Utility Room · Qualified 2025-07-25

Verified Specification Summary

Homeowners specifying Broan-Nutone PCPER811 = PCPE811H with PCPER811F gain 110 CFM at 0.1 in. w.g. (94.1 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 4.2 CFM/W efficacy, venting bathrooms up to 94 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone PCPER811 = PCPE811H with PCPER811F before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 94.1 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.2 CFM/W (#774/1,145)

- **Static Retention**: 85.5% @ 0.25"

- **Motor Draw**: 26.2 W (9.6 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan-Nutone PCPER811 = PCPE811H with PCPER811F vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan-Nutone PCPER811 = PCPE811H with PCPER811F (EPA filing PD #4481304) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 94.1 CFM out of 110 CFM (85.5% retention, 2.2 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places PCPER811 = PCPE811H with PCPER811F (series: FLEX SERIES) (PD #4481304) among 48 Broan-Nutone entries qualified through 2025-07-25. Lighting kit: No. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.2 watts, about 9.6 kWh/yr (~$1.54/yr at $0.16/kWh) for 1 hr/day shower timers or 229.5 kWh/yr (~$36.72/yr) continuously. Closest competing matches include Broan AER110LTMB (110.0 CFM) and Broan AER110LTW (110.0 CFM).

## Which exterior damper path suits Broan-Nutone PCPER811 = PCPE811H with PCPER811F best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Broan-Nutone PCPER811 = PCPE811H with PCPER811F housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Broan-Nutone PCPER811 = PCPE811H with PCPER811F acoustic and static metrics stand?

Compare Broan-Nutone PCPER811 = PCPE811H with PCPER811F published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan-Nutone (48 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | PCPER811 = PCPE811H with PCPER811F / FLEX SERIES | PD ID 4481304 (Qualified 2025-07-25) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (94.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can Broan-Nutone PCPER811 = PCPE811H with PCPER811F handle taller ceilings or walk-in tub steam?

Evaluate how Broan-Nutone PCPER811 = PCPE811H with PCPER811F scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Broan-Nutone PCPER811 = PCPE811H with PCPER811F

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 94 sq ft | 1 CFM/sq ft @ 94.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 83 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 44 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.6 kWh/yr (~$1.54/yr) | 26.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 229.5 kWh/yr (~$36.72/yr) | 26.2 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Broan-Nutone PCPER811 = PCPE811H with PCPER811F?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan AER110LTMB**](https://siematic-charleston.com/ventilation-fans/broan-aer110ltmb/) | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**Broan AER110LTW**](https://siematic-charleston.com/ventilation-fans/broan-aer110ltw/) | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**Nutone AER110SLW**](https://siematic-charleston.com/ventilation-fans/nutone-aer110slw/) | 110 / 89.5 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**Nutone AERN110LTK**](https://siematic-charleston.com/ventilation-fans/nutone-aern110ltk/) | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**Nutone AERN110LTW**](https://siematic-charleston.com/ventilation-fans/nutone-aern110ltw/) | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |

## Is Broan-Nutone PCPER811 = PCPE811H with PCPER811F sized right for your shower or tub room?

Check whether Broan-Nutone PCPER811 = PCPE811H with PCPER811F clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Broan-Nutone PCPER811 = PCPE811H with PCPE in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Broan-Nutone PCPER811 = PCPE811H with PCPE for residential use.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 44 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Ideal fit:** Moisture load fits 94.1 CFM net static output
- **Primary match:** Collar pairs with 4 in. diameter duct straight outdoors

## Which code checks and cost facts matter for Broan-Nutone PCPER811 = PCPE811H with PCPER811F?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Broan-Nutone PCPER811 = PCPE811H with PCPER811F.

### How does Broan-Nutone PCPER811 = PCPE811H with PCPER811F sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Broan-Nutone PCPER811 = PCPE811H with PCPER811F produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Broan-Nutone PCPER811 = PCPE811H with PCPER811F?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Broan-Nutone PCPER811 = PCPE811H with PCPER811F pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone PCPER811 = PCPE811H with PCPER811F's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan-Nutone PCPER811 = PCPE811H with PCPER811F?

Broan-Nutone PCPER811 = PCPE811H with PCPER811F features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan-Nutone PCPER811 = PCPE811H with PCPER811F's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone PCPER811 = PCPE811H with PCPER811F's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Broan-Nutone PCPER811 = PCPE811H with PCPER811F satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone PCPER811 = PCPE811H with PCPER811F clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Broan-Nutone PCPER811 = PCPE811H with PCPER811F undersized or poorly matched for a bath renovation?

Skip Broan-Nutone PCPER811 = PCPE811H with PCPER811F if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Broan-Nutone PCPER811 = PCPE811H with PCPER811F CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Broan-Nutone PCPER811 = PCPE811H with PCPER811F registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

## How can you cross-check Broan-Nutone PCPER811 = PCPE811H with PCPER811F against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Broan-Nutone PCPER811 = PCPE811H with PCPER811F.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan PCPE811CCTK Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-pcpe811cctk/)
- [Broan ZB110HL1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-zb110hl1/)
- [Broan-Nutone PCPER811 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-nutone-pcper811/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)