#  Broan-Nutone PCPER811 Exhaust Fan Specifications

ENERGY STAR PD #4481306 · Bathroom/Utility Room · Qualified 2025-07-25

Verified Specification Summary

Certified by EPA ENERGY STAR, Broan-Nutone PCPER811 delivers 110 CFM free-air (94.1 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 4.2 CFM/W efficacy, clearing residential IRC M1505 sizing up to 94 sq ft (8-ft height) or 83 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone PCPER811 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 94.1 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.2 CFM/W (#774/1,145)

- **Static Retention**: 85.5% @ 0.25"

- **Motor Draw**: 26.2 W (9.6 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan-Nutone PCPER811 vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan-Nutone PCPER811 (EPA filing PD #4481306) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 94.1 CFM out of 110 CFM (85.5% retention, 2.2 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Broan-Nutone PCPER811 (series: FLEX SERIES) under PD #4481306 (48 models registered, 2025-07-25). Lighting kit: No. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.2 watts, about 9.6 kWh/yr (~$1.54/yr at $0.16/kWh) for 1 hr/day shower timers or 229.5 kWh/yr (~$36.72/yr) continuously. Closest competing matches include Broan AER110LTMB (110.0 CFM) and Broan AER110LTW (110.0 CFM).

## Why does rigid 4 in. diameter ducting protect Broan-Nutone PCPER811 airflow?

Connecting Broan-Nutone PCPER811 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Broan-Nutone PCPER811 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Broan-Nutone PCPER811 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan-Nutone (48 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | PCPER811 / FLEX SERIES | PD ID 4481306 (Qualified 2025-07-25) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (94.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Broan-Nutone PCPER811?

Calculated coverage metrics translate Broan-Nutone PCPER811 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Broan-Nutone PCPER811

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 94 sq ft | 1 CFM/sq ft @ 94.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 83 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 44 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.6 kWh/yr (~$1.54/yr) | 26.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 229.5 kWh/yr (~$36.72/yr) | 26.2 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Broan-Nutone PCPER811?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan AER110LTMB**](https://siematic-charleston.com/ventilation-fans/broan-aer110ltmb/) | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**Broan AER110LTW**](https://siematic-charleston.com/ventilation-fans/broan-aer110ltw/) | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**Nutone AER110SLW**](https://siematic-charleston.com/ventilation-fans/nutone-aer110slw/) | 110 / 89.5 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**Nutone AERN110LTK**](https://siematic-charleston.com/ventilation-fans/nutone-aern110ltk/) | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**Nutone AERN110LTW**](https://siematic-charleston.com/ventilation-fans/nutone-aern110ltw/) | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |

## Does Broan-Nutone PCPER811 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Broan-Nutone PCPER811 percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Broan-Nutone PCPER811 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan-Nutone PCPER811.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 44 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Recommended when:** Moisture load fits 94.1 CFM net static output
- **Target scenario:** Collar pairs with 4 in. diameter duct straight outdoors

## Which homeowner questions come up most for Broan-Nutone PCPER811?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Broan-Nutone PCPER811.

### Will Broan-Nutone PCPER811 disturb adjacent bedrooms during night use?

Acoustic measurement places Broan-Nutone PCPER811 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

### Does running Broan-Nutone PCPER811 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Broan-Nutone PCPER811 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Broan-Nutone PCPER811 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone PCPER811's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan-Nutone PCPER811?

Broan-Nutone PCPER811 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan-Nutone PCPER811's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone PCPER811's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Broan-Nutone PCPER811 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone PCPER811 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Broan-Nutone PCPER811?

Do not force Broan-Nutone PCPER811 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Broan-Nutone PCPER811 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Broan-Nutone PCPER811 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

## Where can you explore more benchmarks around Broan-Nutone PCPER811?

Use the related reference pages and estimators below to cross-check Broan-Nutone PCPER811 against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan-Nutone PCPER811 = PCPE811H with PCPER811F Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-nutone-pcper811-pcpe811h-with-pcper811f/)
- [Broan PCPE811CCTK Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-pcpe811cctk/)
- [Broan-Nutone PCPE811K = PCPE811H with PCPE811KF Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-nutone-pcpe811k-pcpe811h-with-pcpe811kf/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)