#  Broan QTXE110150DCL Exhaust Fan Specifications

ENERGY STAR PD #2338643 · Bathroom/Utility Room · Qualified 2019-05-17

Verified Specification Summary

Tested under HVI protocols, the Broan QTXE110150DCL exhaust unit achieves 150 CFM at 0.1 in. w.g. (147.8 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 11.0 CFM/W efficacy, covering standard baths up to 147 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan QTXE110150DCL Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 150 / 147.8 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 11.0 CFM/W (#131/1,145)

- **Static Retention**: 98.5% @ 0.25"

- **Motor Draw**: 13.6 W (5.0 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan QTXE110150DCL vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan QTXE110150DCL (EPA filing PD #2338643) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 147.8 CFM out of 150 CFM (98.5% retention, 10.8 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Broan maintains 207 active ENERGY STAR blowers; QTXE110150DCL (series: QT DC) (PD #2338643) gained qualification on 2019-05-17. Lighting kit: Yes. At 11.0 CFM/W (#131 of 1,145, top 12.0% of 1,145 rated models, more efficient than 88.0% of rated models, 6.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 13.6 watts, about 5.0 kWh/yr (~$0.80/yr at $0.16/kWh) for 1 hr/day shower timers or 119.1 kWh/yr (~$19.06/yr) continuously. Closest competing matches include KORA SBF160DC-MS (161.6 CFM) and Loren Cook Company GCVF 100 (127.0 CFM).

## What attic duct routing preserves Broan QTXE110150DCL CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Broan QTXE110150DCL, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Broan QTXE110150DCL measure up on airflow and noise ratings?

Each row below breaks down Broan QTXE110150DCL certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan (207 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | QTXE110150DCL / QT DC | PD ID 2338643 (Qualified 2019-05-17) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (147.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How does ceiling height affect Broan QTXE110150DCL CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Broan QTXE110150DCL

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 147 sq ft | 1 CFM/sq ft @ 147.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 131 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 97 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.0 kWh/yr (~$0.80/yr) | 13.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 119.1 kWh/yr (~$19.06/yr) | 13.6 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Broan QTXE110150DCL?

Compare Broan QTXE110150DCL side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**KORA SBF160DC-MS**](https://siematic-charleston.com/ventilation-fans/kora-sbf160dc-ms/) | 161.6 / N/A CFM | 1.3 sones | 8.7 CFM/W | 4 in. diameter |
| [**Loren Cook Company GCVF 100**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gcvf-100/) | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |
| [**Panasonic FV-1315RQ2**](https://siematic-charleston.com/ventilation-fans/panasonic-fv-1315rq2/) | 150 / 143.3 CFM | Unpublished | 10.6 CFM/W | 6 in. diameter |
| [**Panasonic RG-C1315A**](https://siematic-charleston.com/ventilation-fans/panasonic-rg-c1315a/) | 150 / 143.3 CFM | Unpublished | 10.6 CFM/W | 6 in. diameter |
| [**Panasonic RG-C1315LA**](https://siematic-charleston.com/ventilation-fans/panasonic-rg-c1315la/) | 150 / 143.3 CFM | Unpublished | 10.6 CFM/W | 6 in. diameter |

## Can you size Broan QTXE110150DCL for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan QTXE110150DCL verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Broan QTXE110150DCL suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan QTXE110150DCL for your remodel.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 147.8 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Strong scenario:** Target comfort around ENERGY STAR sones up to 147 sq ft
- **Best application:** Paired with rigid galvanized 6 in. diameter transition

## How do federal and code standards apply to Broan QTXE110150DCL?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan QTXE110150DCL.

### Who should NOT install Broan QTXE110150DCL in a bathroom remodel?

Avoid specifying Broan QTXE110150DCL in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut Broan QTXE110150DCL airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan QTXE110150DCL achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does Broan QTXE110150DCL occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Broan QTXE110150DCL produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

### How many kWh per year does Broan QTXE110150DCL add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Broan QTXE110150DCL averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Broan QTXE110150DCL pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan QTXE110150DCL's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan QTXE110150DCL?

Broan QTXE110150DCL features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan QTXE110150DCL's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan QTXE110150DCL's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Broan QTXE110150DCL pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan QTXE110150DCL easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

## What neighboring pages and tools support Broan QTXE110150DCL?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Broan QTXE110150DCL.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan QTXE110150DCL=QTXEDCLH with QTXE110150DCLF Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-qtxe110150dcl-qtxedclh-with-qtxe110150dclf/)
- [Delta SMT150D Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-smt150d/)
- [Broan QTXE110150DC=QTXEDCH with QTXE110150DCF Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-qtxe110150dc-qtxedch-with-qtxe110150dcf/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)