title: "Broan XB50=XB00HwithXB50F Bath Fan (50 CFM, 0.2 Sone)"
url: https://siematic-charleston.com/ventilation-fans/broan-xb50-xb00hwithxb50f/
description: "ENERGY STAR specs for Broan XB50=XB00HwithXB50F: 50 CFM, 0.2 sones (#18 of 607), 11.8 CFM/W, 6 in. diameter and 5 closest peer fans."
---

#  Broan XB50=XB00HwithXB50F Exhaust Fan Specifications

ENERGY STAR PD #2333771 · Bathroom/Utility Room · Qualified 2019-02-15

Verified Specification Summary

Rated for 50 CFM open-air (57.8 CFM at 0.25 in. w.g.), Broan XB50=XB00HwithXB50F registers #18 of 607 in quietness (0.2 sones) and delivers 11.8 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 57 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan XB50=XB00HwithXB50F Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 50 / 57.8 CFM

- **Noise @ 0.1"**: 0.2 sones (#18/607)

- **Efficacy Rank**: 11.8 CFM/W (#90/1,145)

- **Static Retention**: 115.6% @ 0.25"

- **Motor Draw**: 4.2 W (1.5 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan XB50=XB00HwithXB50F vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.2 sones (#18 of 607 rated models, quietest 3.8% of 607 rated models, quieter than 96.2% of rated models, 0.80 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 57.8 CFM out of 50 CFM (115.6% retention, 27.9 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside Broan's 207-unit lineup, XB50=XB00HwithXB50F (series: ULTRA GREEN) carries PD #2333771 dating to 2019-02-15. Lighting kit: No. At 11.8 CFM/W (#90 of 1,145, top 8.9% of 1,145 rated models, more efficient than 91.1% of rated models, 7.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 4.2 watts, about 1.5 kWh/yr (~$0.24/yr at $0.16/kWh) for 1 hr/day shower timers or 36.8 kWh/yr (~$5.89/yr) continuously. Closest competing matches include Broan XB50L1 (50.0 CFM) and Broan XB50 (50.0 CFM).

## How does Broan XB50=XB00HwithXB50F acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Broan XB50=XB00HwithXB50F (0.2 sones).

## How do flex elbows choke Broan XB50=XB00HwithXB50F at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Broan XB50=XB00HwithXB50F moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Broan XB50=XB00HwithXB50F meet residential exhaust fan code specs?

Inspect Broan XB50=XB00HwithXB50F mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan (207 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | XB50=XB00HwithXB50F / ULTRA GREEN | PD ID 2333771 (Qualified 2019-02-15) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (57.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.2 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Which bathroom duties match Broan XB50=XB00HwithXB50F airflow output?

Annual electricity figures and room square-footage ceilings below reflect Broan XB50=XB00HwithXB50F tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Broan XB50=XB00HwithXB50F

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 57 sq ft | 1 CFM/sq ft @ 57.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 51 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 1.5 kWh/yr (~$0.24/yr) | 4.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 36.8 kWh/yr (~$5.89/yr) | 4.2 W x 8,760 hrs / 1,000 |

## Which competing models share Broan XB50=XB00HwithXB50F airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan XB50L1**](https://siematic-charleston.com/ventilation-fans/broan-xb50l1/) | 50 / 55.6 CFM | 0.2 sones (Same) | 11.8 CFM/W | 6 in. diameter |
| [**Broan XB50**](https://siematic-charleston.com/ventilation-fans/broan-xb50/) | 50 / 57.8 CFM | 0.3 sones (+0.10) | 11.8 CFM/W | 6 in. diameter |
| [**Broan XB50**](https://siematic-charleston.com/ventilation-fans/broan-xb50-2248870/) | 50 / 50.1 CFM | 0.3 sones (+0.10) | 9.8 CFM/W | 4 in. diameter |
| [**Broan XB50=XB00HwithXB50F**](https://siematic-charleston.com/ventilation-fans/broan-xb50-xb00hwithxb50f-2333772/) | 50 / 50.1 CFM | 0.3 sones (+0.10) | 9.8 CFM/W | 4 in. diameter |
| [**Broan XB50L1**](https://siematic-charleston.com/ventilation-fans/broan-xb50l1-2394316/) | 50 / 50.5 CFM | 0.3 sones (+0.10) | 9.4 CFM/W | 4 in. diameter |

## How much airflow margin does Broan XB50=XB00HwithXB50F give your bath?

Run a quick local room-volume check for Broan XB50=XB00HwithXB50F by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Broan XB50=XB00HwithXB50F in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Broan XB50=XB00HwithXB50F for residential use.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Ideal fit:** Bathroom floor <= 57 sq ft with 8-ft ceilings (51 sq ft at 9-ft height)
- **Primary match:** Exterior run uses smooth rigid metal matched to 6 in. diameter

## What should homeowners verify first about Broan XB50=XB00HwithXB50F?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Broan XB50=XB00HwithXB50F.

### Why check Broan XB50=XB00HwithXB50F CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Broan XB50=XB00HwithXB50F registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.

### How does Broan XB50=XB00HwithXB50F sound output compare to noisy contractor-grade fans?

Rated at 0.2 sones, Broan XB50=XB00HwithXB50F operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Broan XB50=XB00HwithXB50F?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Broan XB50=XB00HwithXB50F pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan XB50=XB00HwithXB50F's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan XB50=XB00HwithXB50F?

Broan XB50=XB00HwithXB50F features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan XB50=XB00HwithXB50F's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan XB50=XB00HwithXB50F's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Broan XB50=XB00HwithXB50F satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Broan XB50=XB00HwithXB50F clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Broan XB50=XB00HwithXB50F undersized or poorly matched for a bath renovation?

Skip Broan XB50=XB00HwithXB50F if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

## Which GradeMark tools pair best with Broan XB50=XB00HwithXB50F?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Broan XB50=XB00HwithXB50F.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan XB50L1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-xb50l1/)
- [Delta 150F Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-150f/)
- [QuFresh BC80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/qufresh-bc80/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)