---
title: "Broan ZB110L1 Bath Fan (110 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/broan-zb110l1/
description: "ENERGY STAR specs for Broan ZB110L1: 110 CFM, 16.2 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes, and."
---

#  Broan ZB110L1 Exhaust Fan Specifications

ENERGY STAR PD #2312842 · Bathroom/Utility Room · Qualified 2018-03-16

Verified Specification Summary

In EPA dataset 8dv7-nngq, Broan ZB110L1 tests at 110 CFM free discharge (113.2 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 16.2 CFM/W efficacy, meeting residential IRC M1505 sizing up to 113 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan ZB110L1 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 113.2 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 16.2 CFM/W (#12/1,145)

- **Static Retention**: 102.9% @ 0.25"

- **Motor Draw**: 6.8 W (2.5 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Broan ZB110L1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan ZB110L1 (EPA filing PD #2312842) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 113.2 CFM out of 110 CFM (102.9% retention, 15.2 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

EPA filing PD #2312842 verifies ZB110L1 (series: ULTRA GREEN) under Broan (207 listed models, qualified 2018-03-16). Lighting kit: Yes. At 16.2 CFM/W (#12 of 1,145, top 1.2% of 1,145 rated models, more efficient than 98.8% of rated models, 11.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 6.8 watts, about 2.5 kWh/yr (~$0.40/yr at $0.16/kWh) for 1 hr/day shower timers or 59.6 kWh/yr (~$9.54/yr) continuously. Closest competing matches include Panasonic FV-0511VK3 (110.0 CFM) and Panasonic FV-0511VKL3 (110.0 CFM).

## Why avoid unvented attic termination with Broan ZB110L1?

Under ASHRAE 62.2 best practice, Broan ZB110L1 needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Broan ZB110L1?

Before cutting ceiling drywall or sizing attic transitions for Broan ZB110L1, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Broan (207 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | ZB110L1 / ULTRA GREEN | PD ID 2312842 (Qualified 2018-03-16) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (113.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What daily runtime and room footprint suit Broan ZB110L1?

Bathroom ventilation sizing below maps Broan ZB110L1 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Broan ZB110L1

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 113 sq ft | 1 CFM/sq ft @ 113.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 100 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 63 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.5 kWh/yr (~$0.40/yr) | 6.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 59.6 kWh/yr (~$9.54/yr) | 6.8 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Broan ZB110L1 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Broan ZB110L1.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Panasonic FV-0511VK3**](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vk3/) | 110 / 112.9 CFM | Unpublished | 16.7 CFM/W | 6 in. diameter |
| [**Panasonic FV-0511VKL3**](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vkl3-3442063/) | 110 / 114.4 CFM | Unpublished | 15.7 CFM/W | 6 in. diameter |
| [**Panasonic FV-0511VKS3**](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vks3/) | 110 / 112.9 CFM | Unpublished | 16.7 CFM/W | 6 in. diameter |
| [**Panasonic FV-0511VKSL3**](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vksl3/) | 110 / 114.4 CFM | Unpublished | 15.7 CFM/W | 6 in. diameter |
| [**Panasonic FV-0511VKSL3K**](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vksl3k/) | 110 / 111.1 CFM | Unpublished | 15.6 CFM/W | 6 in. diameter |

## What percentage of room demand does Broan ZB110L1 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Broan ZB110L1 tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Broan ZB110L1?

Match Broan ZB110L1 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 113.2 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Best for:** Target comfort around ENERGY STAR sones up to 113 sq ft
- **Optimal use:** Paired with rigid galvanized 6 in. diameter transition

## Where do official rules set limits for Broan ZB110L1?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Broan ZB110L1.

### Where does Broan ZB110L1 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Broan ZB110L1.

### What happens to Broan ZB110L1 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Broan ZB110L1 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.

### Where does Broan ZB110L1 sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Broan ZB110L1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does Broan ZB110L1 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Broan ZB110L1 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Broan ZB110L1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan ZB110L1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Broan ZB110L1?

Broan ZB110L1 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Broan ZB110L1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan ZB110L1's safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can Broan ZB110L1 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Broan ZB110L1 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

## What related resources expand on Broan ZB110L1?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan ZB110ML1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-zb110ml1/)
- [Commercial Electric BF1107 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/commercial-electric-bf1107/)
- [Broan ZB110HL1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-zb110hl1/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
