title: "BSH Home Appliances Corporation HCP30E51UC Bath Fan (122.3 CFM)"
url: https://siematic-charleston.com/ventilation-fans/bsh-home-appliances-corporation-hcp30e51uc/
description: "ENERGY STAR specs for BSH Home Appliances Corporation HCP30E51UC: 122.3 CFM, 3.7 CFM/W, 8 in. diameter and 5 closest peer fans."
---

#  BSH Home Appliances Corporation HCP30E51UC Exhaust Fan Specifications

ENERGY STAR PD #3417667 · Range Hood · Qualified 2024-03-01

Verified Specification Summary

Tested under HVI protocols, the BSH Home Appliances Corporation HCP30E51UC exhaust unit achieves 122.3 CFM at 0.1 in. w.g. (256.3 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 3.7 CFM/W efficacy, covering standard baths up to 256 sq ft on a 8 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside BSH Home Appliances Corporation HCP30E51UC Exhaust Fan before installation.

- **Airflow @ 0.1" / 0.25"**: 122.3 / 256.3 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 3.7 CFM/W (#987/1,145)

- **Static Retention**: 209.6% @ 0.25"

- **Motor Draw**: 33.1 W (12.1 kWh/yr)

- **Duct & Tier**: 8 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does BSH Home Appliances Corporation HCP30E51UC vs. 1,145-Model ENERGY STAR Benchmarks show?

BSH Home Appliances Corporation HCP30E51UC (EPA filing PD #3417667) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 256.3 CFM out of 122.3 CFM (209.6% retention, 121.9 pts higher retention than the 87.7% median). Keep 8 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: BSH Home Appliances Corporation registers 1 certified model, with SKU HCP30E51UC (series: HCP30E51UC) (PD #3417667) certified since 2024-03-01. Lighting kit: No. At 3.7 CFM/W (#987 of 1,145, below median tier among 1,145 rated models; more efficient than 11.3% of rated models, 1.0 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 33.1 watts, about 12.1 kWh/yr (~$1.94/yr at $0.16/kWh) for 1 hr/day shower timers or 290.0 kWh/yr (~$46.40/yr) continuously. Closest competing matches include Greenheck SP-B110ES (118.0 CFM) and KORA SBF110N (119.2 CFM).

## What attic duct routing preserves BSH Home Appliances Corporation HCP30E51UC CFM output?

Short straight 8 in. diameter duct paths retain up to ~82% of open-air capacity on BSH Home Appliances Corporation HCP30E51UC, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does BSH Home Appliances Corporation HCP30E51UC measure up on airflow and noise ratings?

Each row below breaks down BSH Home Appliances Corporation HCP30E51UC certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | BSH Home Appliances Corporation (1 model) | ENERGY STAR Certified Partner |
| **Model Number & Series** | HCP30E51UC / HCP30E51UC | PD ID 3417667 (Qualified 2024-03-01) |
| **Duct Connection** | 8 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (256.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect BSH Home Appliances Corporation HCP30E51UC CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for BSH Home Appliances Corporation HCP30E51UC

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 256 sq ft | 1 CFM/sq ft @ 256.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 227 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 206 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 12.1 kWh/yr (~$1.94/yr) | 33.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 290.0 kWh/yr (~$46.40/yr) | 33.1 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against BSH Home Appliances Corporation HCP30E51UC?

Compare BSH Home Appliances Corporation HCP30E51UC side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Greenheck SP-B110ES**](https://siematic-charleston.com/ventilation-fans/greenheck-sp-b110es/) | 118 / 100 CFM | 1.5 sones | 4.0 CFM/W | 6 in. diameter |
| [**KORA SBF110N**](https://siematic-charleston.com/ventilation-fans/kora-sbf110n/) | 119.2 / N/A CFM | 1.6 sones | 3.5 CFM/W | 4 in. diameter |
| [**Broan QT130LE**](https://siematic-charleston.com/ventilation-fans/broan-qt130le-2404744/) | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Nutone QTN130LE1**](https://siematic-charleston.com/ventilation-fans/nutone-qtn130le1/) | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Broan QT130E**](https://siematic-charleston.com/ventilation-fans/broan-qt130e-4429508/) | 130 / 130.4 CFM | 1.5 sones | 4.7 CFM/W | 6 in. diameter |

## Can you size BSH Home Appliances Corporation HCP30E51UC for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against BSH Home Appliances Corporation HCP30E51UC verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip BSH Home Appliances Corporation HCP30E51UC on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for BSH Home Appliances Corporation HCP30E51UC carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 256.3 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Choose this if:** Target comfort around ENERGY STAR sones up to 256 sq ft
- **Works well for:** Paired with rigid galvanized 8 in. diameter transition

## How do federal and code standards apply to BSH Home Appliances Corporation HCP30E51UC?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for BSH Home Appliances Corporation HCP30E51UC.

### Will long attic ducting choke BSH Home Appliances Corporation HCP30E51UC capacity?

Because static drag at 0.25 in. w.g. lowers BSH Home Appliances Corporation HCP30E51UC from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 8 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is BSH Home Appliances Corporation HCP30E51UC compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, BSH Home Appliances Corporation HCP30E51UC produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does BSH Home Appliances Corporation HCP30E51UC consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, BSH Home Appliances Corporation HCP30E51UC draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can BSH Home Appliances Corporation HCP30E51UC pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from BSH Home Appliances Corporation HCP30E51UC's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing BSH Home Appliances Corporation HCP30E51UC?

BSH Home Appliances Corporation HCP30E51UC features a 8 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change BSH Home Appliances Corporation HCP30E51UC's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing BSH Home Appliances Corporation HCP30E51UC's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does BSH Home Appliances Corporation HCP30E51UC score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), BSH Home Appliances Corporation HCP30E51UC delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify BSH Home Appliances Corporation HCP30E51UC?

Rule out BSH Home Appliances Corporation HCP30E51UC when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

## What neighboring pages and tools support BSH Home Appliances Corporation HCP30E51UC?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around BSH Home Appliances Corporation HCP30E51UC.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Air King ESQZ2308 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-esqz2308/)
- [Air King ESZ303ADA Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-esz303ada/)
- [Aprilaire 8144NC Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aprilaire-8144nc/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)