title: "BV BV-BF-01-PLUS Bath Fan (90 CFM, 0.8 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/bv-bv-bf-01-plus/
description: "ENERGY STAR specs for BV BV-BF-01-PLUS: 90 CFM, 0.8 sones (#194 of 607), 4.8 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency."
---

#  BV BV-BF-01-PLUS Exhaust Fan Specifications

ENERGY STAR PD #3994341 · Bathroom/Utility Room · Qualified 2025-01-24

Verified Specification Summary

Tested under HVI protocols, the BV BV-BF-01-PLUS exhaust unit achieves 90 CFM at 0.1 in. w.g. (82.9 CFM at 0.25 in. w.g.), registers #194 of 607 in quietness (0.8 sones) and delivers 4.8 CFM/W efficacy, covering standard baths up to 82 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside BV BV-BF-01-PLUS Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 90 / 82.9 CFM

- **Noise @ 0.1"**: 0.8 sones (#194/607)

- **Efficacy Rank**: 4.8 CFM/W (#534/1,145)

- **Static Retention**: 92.1% @ 0.25"

- **Motor Draw**: 18.8 W (6.9 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does BV BV-BF-01-PLUS vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 82.9 CFM out of 90 CFM (92.1% retention, 4.4 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside BV's 3-unit lineup, BV-BF-01-PLUS (series: BV-BF-01-PLUS) carries PD #3994341 dating to 2025-01-24. Lighting kit: No. At 4.8 CFM/W (#534 of 1,145, top 47.5% of 1,145 rated models, more efficient than 52.5% of rated models, 0.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 18.8 watts, about 6.9 kWh/yr (~$1.10/yr at $0.16/kWh) for 1 hr/day shower timers or 164.7 kWh/yr (~$26.35/yr) continuously. Closest competing matches include Ortech ODC-9008 (90.0 CFM) and Air King AK90LS6 (90.0 CFM).

## Where do BV BV-BF-01-PLUS sones rank across EPA ENERGY STAR fans?

Comparing BV BV-BF-01-PLUS (0.8 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves BV BV-BF-01-PLUS CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on BV BV-BF-01-PLUS, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does BV BV-BF-01-PLUS measure up on airflow and noise ratings?

Each row below breaks down BV BV-BF-01-PLUS certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | BV (3 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | BV-BF-01-PLUS / BV-BF-01-PLUS | PD ID 3994341 (Qualified 2025-01-24) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (82.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.8 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect BV BV-BF-01-PLUS CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for BV BV-BF-01-PLUS

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 82 sq ft | 1 CFM/sq ft @ 82.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 73 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 32 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.9 kWh/yr (~$1.10/yr) | 18.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 164.7 kWh/yr (~$26.35/yr) | 18.8 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against BV BV-BF-01-PLUS?

Compare BV BV-BF-01-PLUS side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Ortech ODC-9008**](https://siematic-charleston.com/ventilation-fans/ortech-odc-9008/) | 90 / 97.3 CFM | 0.8 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| [**Air King AK90LS6**](https://siematic-charleston.com/ventilation-fans/air-king-ak90ls6/) | 90 / 72.7 CFM | 0.8 sones (Same) | 4.5 CFM/W | 6 in. diameter |
| [**Tech Drive TD-BF-11-plus**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-11-plus/) | 90 / 79.5 CFM | 0.8 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| [**Dayton 5AE68B**](https://siematic-charleston.com/ventilation-fans/dayton-5ae68b/) | 90 / N/A CFM | 0.8 sones (Same) | 4.3 CFM/W | 6 in. diameter |
| [**Greenheck SP-B90**](https://siematic-charleston.com/ventilation-fans/greenheck-sp-b90/) | 90 / 72 CFM | 0.8 sones (Same) | 4.3 CFM/W | 6 in. diameter |

## Can you size BV BV-BF-01-PLUS for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against BV BV-BF-01-PLUS verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out BV BV-BF-01-PLUS?

Compare where BV BV-BF-01-PLUS excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 82.9 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Target comfort around 0.8 sones up to 82 sq ft
- **Suited to:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to BV BV-BF-01-PLUS?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for BV BV-BF-01-PLUS.

### Why might a contractor swap BV BV-BF-01-PLUS for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, BV BV-BF-01-PLUS lacks adequate reserve.

### How does BV BV-BF-01-PLUS handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., BV BV-BF-01-PLUS yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

### Is BV BV-BF-01-PLUS quiet enough for a primary bedroom bathroom?

At 0.8 sones, BV BV-BF-01-PLUS operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is BV BV-BF-01-PLUS energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can BV BV-BF-01-PLUS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from BV BV-BF-01-PLUS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing BV BV-BF-01-PLUS?

BV BV-BF-01-PLUS features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change BV BV-BF-01-PLUS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing BV BV-BF-01-PLUS's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can BV BV-BF-01-PLUS serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: BV BV-BF-01-PLUS supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

## What neighboring pages and tools support BV BV-BF-01-PLUS?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around BV BV-BF-01-PLUS.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [BV BV-BF-05 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/bv-bv-bf-05/)
- [Dayton 5AE68B Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/dayton-5ae68b/)
- [Air King AK90LS6 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-ak90ls6/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)