title: "BV BV-BF-02-PLUS Bath Fan (110 CFM, 1.2 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/bv-bv-bf-02-plus/
description: "ENERGY STAR specs for BV BV-BF-02-PLUS: 110 CFM, 1.2 sones (#380 of 607), 4.8 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency."
---

#  BV BV-BF-02-PLUS Exhaust Fan Specifications

ENERGY STAR PD #4008361 · Bathroom/Utility Room · Qualified 2025-03-07

Verified Specification Summary

Tested under HVI protocols, the BV BV-BF-02-PLUS exhaust unit achieves 110 CFM at 0.1 in. w.g. (99 CFM at 0.25 in. w.g.), registers #380 of 607 in quietness (1.2 sones) and delivers 4.8 CFM/W efficacy, covering standard baths up to 99 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside BV BV-BF-02-PLUS Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 99 CFM

- **Noise @ 0.1"**: 1.2 sones (#380/607)

- **Efficacy Rank**: 4.8 CFM/W (#534/1,145)

- **Static Retention**: 90.0% @ 0.25"

- **Motor Draw**: 22.9 W (8.4 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does BV BV-BF-02-PLUS vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.2 sones (#380 of 607 rated models, 0.20 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 99 CFM out of 110 CFM (90.0% retention, 2.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: BV registers 3 certified models, with SKU BV-BF-02-PLUS (series: BV-BF-02-PLUS) (PD #4008361) certified since 2025-03-07. Lighting kit: No. At 4.8 CFM/W (#534 of 1,145, top 47.5% of 1,145 rated models, more efficient than 52.5% of rated models, 0.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 22.9 watts, about 8.4 kWh/yr (~$1.34/yr at $0.16/kWh) for 1 hr/day shower timers or 200.6 kWh/yr (~$32.10/yr) continuously. Closest competing matches include Valu+ BPT14-24TGHS (110.0 CFM) and Nektra 3291028 (110.0 CFM).

## Where do BV BV-BF-02-PLUS sones rank across EPA ENERGY STAR fans?

Comparing BV BV-BF-02-PLUS (1.2 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves BV BV-BF-02-PLUS CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on BV BV-BF-02-PLUS, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does BV BV-BF-02-PLUS measure up on airflow and noise ratings?

Each row below breaks down BV BV-BF-02-PLUS certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | BV (3 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | BV-BF-02-PLUS / BV-BF-02-PLUS | PD ID 4008361 (Qualified 2025-03-07) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (99 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.2 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect BV BV-BF-02-PLUS CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for BV BV-BF-02-PLUS

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 99 sq ft | 1 CFM/sq ft @ 99 CFM |
| Tall Bath (9-ft Ceiling) | Up to 88 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 49 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.4 kWh/yr (~$1.34/yr) | 22.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 200.6 kWh/yr (~$32.10/yr) | 22.9 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against BV BV-BF-02-PLUS?

Compare BV BV-BF-02-PLUS side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Valu+ BPT14-24TGHS**](https://siematic-charleston.com/ventilation-fans/valu-bpt14-24tghs/) | 110 / 99 CFM | 1.2 sones (Same) | 4.8 CFM/W | 4 in. diameter |
| [**Nektra 3291028**](https://siematic-charleston.com/ventilation-fans/nektra-3291028/) | 110 / 98.7 CFM | 1.2 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| [**Win Air BPT14-24E**](https://siematic-charleston.com/ventilation-fans/win-air-bpt14-24e/) | 110 / 98.7 CFM | 1.2 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| [**COSTWAY BPT14-24A-A-1**](https://siematic-charleston.com/ventilation-fans/costway-bpt14-24a-a-1/) | 110 / 97.5 CFM | 1.2 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| [**Loren Cook Company GC-222**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gc-222/) | 115 / 85 CFM | 1.2 sones (Same) | 4.8 CFM/W | 4.5 x 6 in. rectangular |

## Can you size BV BV-BF-02-PLUS for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against BV BV-BF-02-PLUS verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does BV BV-BF-02-PLUS fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering BV BV-BF-02-PLUS.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 99 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Recommended when:** Target comfort around 1.2 sones up to 99 sq ft
- **Target scenario:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to BV BV-BF-02-PLUS?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for BV BV-BF-02-PLUS.

### How much airflow does BV BV-BF-02-PLUS retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, BV BV-BF-02-PLUS produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

### Will BV BV-BF-02-PLUS disturb adjacent bedrooms during night use?

Acoustic measurement places BV BV-BF-02-PLUS at 1.2 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

### Does running BV BV-BF-02-PLUS continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of BV BV-BF-02-PLUS draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can BV BV-BF-02-PLUS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from BV BV-BF-02-PLUS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing BV BV-BF-02-PLUS?

BV BV-BF-02-PLUS features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change BV BV-BF-02-PLUS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing BV BV-BF-02-PLUS's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is BV BV-BF-02-PLUS code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), BV BV-BF-02-PLUS clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than BV BV-BF-02-PLUS?

Do not force BV BV-BF-02-PLUS into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

## What neighboring pages and tools support BV BV-BF-02-PLUS?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around BV BV-BF-02-PLUS.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [COSTWAY BPT14-24A-A-1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/costway-bpt14-24a-a-1/)
- [Nektra 3291028 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/nektra-3291028/)
- [Loren Cook Company GC-222 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gc-222/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)