#  BV BV-BF-05 Exhaust Fan Specifications

ENERGY STAR PD #3553991 · Bathroom/Utility Room · Qualified 2024-05-24

Verified Specification Summary

Rated for 90 CFM open-air (75.4 CFM at 0.25 in. w.g.), BV BV-BF-05 registers #194 of 607 in quietness (0.8 sones) and delivers 4.8 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 75 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside BV BV-BF-05 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 90 / 75.4 CFM

- **Noise @ 0.1"**: 0.8 sones (#194/607)

- **Efficacy Rank**: 4.8 CFM/W (#534/1,145)

- **Static Retention**: 83.8% @ 0.25"

- **Motor Draw**: 18.8 W (6.9 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does BV BV-BF-05 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 90 CFM open-air to 75.4 CFM at 0.25 in. w.g. (83.8% retention, 3.9 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms BV BV-BF-05 (series: BV-BF-05) under PD #3553991 (3 models registered, 2024-05-24). Lighting kit: Yes. At 4.8 CFM/W (#534 of 1,145, top 47.5% of 1,145 rated models, more efficient than 52.5% of rated models, 0.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 18.8 watts, about 6.9 kWh/yr (~$1.10/yr at $0.16/kWh) for 1 hr/day shower timers or 164.7 kWh/yr (~$26.35/yr) continuously. Closest competing matches include Ortech ODC-9008 (90.0 CFM) and Air King AK90LS6 (90.0 CFM).

## How does BV BV-BF-05 acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against BV BV-BF-05 (0.8 sones).

## How do flex elbows choke BV BV-BF-05 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps BV BV-BF-05 moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does BV BV-BF-05 meet residential exhaust fan code specs?

Inspect BV BV-BF-05 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | BV (3 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | BV-BF-05 / BV-BF-05 | PD ID 3553991 (Qualified 2024-05-24) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (75.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.8 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## Which bathroom duties match BV BV-BF-05 airflow output?

Annual electricity figures and room square-footage ceilings below reflect BV BV-BF-05 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for BV BV-BF-05

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 75 sq ft | 1 CFM/sq ft @ 75.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 67 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 25 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.9 kWh/yr (~$1.10/yr) | 18.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 164.7 kWh/yr (~$26.35/yr) | 18.8 W x 8,760 hrs / 1,000 |

## Which competing models share BV BV-BF-05 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Ortech ODC-9008**](https://siematic-charleston.com/ventilation-fans/ortech-odc-9008/) | 90 / 97.3 CFM | 0.8 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| [**Air King AK90LS6**](https://siematic-charleston.com/ventilation-fans/air-king-ak90ls6/) | 90 / 72.7 CFM | 0.8 sones (Same) | 4.5 CFM/W | 6 in. diameter |
| [**Tech Drive TD-BF-11-plus**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-11-plus/) | 90 / 79.5 CFM | 0.8 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| [**Dayton 5AE68B**](https://siematic-charleston.com/ventilation-fans/dayton-5ae68b/) | 90 / N/A CFM | 0.8 sones (Same) | 4.3 CFM/W | 6 in. diameter |
| [**Greenheck SP-B90**](https://siematic-charleston.com/ventilation-fans/greenheck-sp-b90/) | 90 / 72 CFM | 0.8 sones (Same) | 4.3 CFM/W | 6 in. diameter |

## How much airflow margin does BV BV-BF-05 give your bath?

Run a quick local room-volume check for BV BV-BF-05 by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does BV BV-BF-05 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering BV BV-BF-05.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 25 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Recommended when:** Bathroom floor <= 75 sq ft with 8-ft ceilings (67 sq ft at 9-ft height)
- **Target scenario:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What should homeowners verify first about BV BV-BF-05?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to BV BV-BF-05.

### Does running BV BV-BF-05 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of BV BV-BF-05 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can BV BV-BF-05 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from BV BV-BF-05's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing BV BV-BF-05?

BV BV-BF-05 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change BV BV-BF-05's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing BV BV-BF-05's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is BV BV-BF-05 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), BV BV-BF-05 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than BV BV-BF-05?

Do not force BV BV-BF-05 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does BV BV-BF-05 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, BV BV-BF-05 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

### Will BV BV-BF-05 disturb adjacent bedrooms during night use?

Acoustic measurement places BV BV-BF-05 at 0.8 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.

## Which GradeMark tools pair best with BV BV-BF-05?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to BV BV-BF-05.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Dayton 5AE68B Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/dayton-5ae68b/)
- [Greenheck SP-B90 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/greenheck-sp-b90/)
- [BV BV-BF-01-PLUS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/bv-bv-bf-01-plus/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)