#  CFM TF140-EC Exhaust Fan Specifications

ENERGY STAR PD #2624891 · Bathroom/Utility Room · Qualified 2023-07-28

Verified Specification Summary

Tested under HVI protocols, the CFM TF140-EC exhaust unit achieves 140 CFM at 0.1 in. w.g. (146.6 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 11.5 CFM/W efficacy, covering standard baths up to 146 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside CFM TF140-EC Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 140 / 146.6 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 11.5 CFM/W (#106/1,145)

- **Static Retention**: 104.7% @ 0.25"

- **Motor Draw**: 12.2 W (4.5 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does CFM TF140-EC vs. 1,145-Model ENERGY STAR Benchmarks show?

CFM TF140-EC (EPA filing PD #2624891) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 146.6 CFM out of 140 CFM (104.7% retention, 17.0 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

CFM maintains 4 active ENERGY STAR blowers; TF140-EC (series: TF) (PD #2624891) gained qualification on 2023-07-28. Lighting kit: No. At 11.5 CFM/W (#106 of 1,145, top 10.0% of 1,145 rated models, more efficient than 90.0% of rated models, 6.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.2 watts, about 4.5 kWh/yr (~$0.72/yr at $0.16/kWh) for 1 hr/day shower timers or 106.9 kWh/yr (~$17.10/yr) continuously. Closest competing matches include Loren Cook Company GCVF 100 (127.0 CFM) and ACIQ AEPD140-3 (140.0 CFM).

## What attic duct routing preserves CFM TF140-EC CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on CFM TF140-EC, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does CFM TF140-EC measure up on airflow and noise ratings?

Each row below breaks down CFM TF140-EC certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | CFM (4 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | TF140-EC / TF | PD ID 2624891 (Qualified 2023-07-28) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (146.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect CFM TF140-EC CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for CFM TF140-EC

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 146 sq ft | 1 CFM/sq ft @ 146.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 130 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 96 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.5 kWh/yr (~$0.72/yr) | 12.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 106.9 kWh/yr (~$17.10/yr) | 12.2 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against CFM TF140-EC?

Compare CFM TF140-EC side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Loren Cook Company GCVF 100**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gcvf-100/) | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |
| [**ACIQ AEPD140-3**](https://siematic-charleston.com/ventilation-fans/aciq-aepd140-3/) | 140 / 146.6 CFM | Unpublished | 11.5 CFM/W | 6 in. diameter |
| [**Haier QVE110DTWW**](https://siematic-charleston.com/ventilation-fans/haier-qve110dtww/) | 140 / 146.6 CFM | Unpublished | 11.5 CFM/W | 6 in. diameter |
| [**Ortech ODD-110-18PB**](https://siematic-charleston.com/ventilation-fans/ortech-odd-110-18pb/) | 140 / 146.6 CFM | Unpublished | 11.5 CFM/W | 6 in. diameter |
| [**S&P PCD110XP**](https://siematic-charleston.com/ventilation-fans/s-p-pcd110xp/) | 140 / 146.6 CFM | Unpublished | 11.5 CFM/W | 6 in. diameter |

## Can you size CFM TF140-EC for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against CFM TF140-EC verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip CFM TF140-EC on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for CFM TF140-EC carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 146.6 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Choose this if:** Target comfort around ENERGY STAR sones up to 146 sq ft
- **Works well for:** Paired with rigid galvanized 6 in. diameter transition

## How do federal and code standards apply to CFM TF140-EC?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for CFM TF140-EC.

### How loud is CFM TF140-EC compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, CFM TF140-EC produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does CFM TF140-EC consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, CFM TF140-EC draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can CFM TF140-EC pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from CFM TF140-EC's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing CFM TF140-EC?

CFM TF140-EC features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change CFM TF140-EC's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing CFM TF140-EC's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does CFM TF140-EC score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), CFM TF140-EC delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify CFM TF140-EC?

Rule out CFM TF140-EC when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke CFM TF140-EC capacity?

Because static drag at 0.25 in. w.g. lowers CFM TF140-EC from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.

## What neighboring pages and tools support CFM TF140-EC?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around CFM TF140-EC.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Haier QVE110DTWW Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/haier-qve110dtww/)
- [Ortech ODD-110-18PB Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ortech-odd-110-18pb/)
- [Broan L100E Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-l100e/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)