title: "Commercial Electric 7130-20-CE Bath Fan (110 CFM, 1.5 Sone)"
url: https://siematic-charleston.com/ventilation-fans/commercial-electric-7130-20-ce/
description: "ENERGY STAR specs for Commercial Electric 7130-20-CE: 110 CFM, 1.5 sones (#412 of 607), 3.9 CFM/W, 4 in. diameter and 5 closest peer fans."
---

#  Commercial Electric 7130-20-CE Exhaust Fan Specifications

ENERGY STAR PD #3477948 · Bathroom/Utility Room · Qualified 2024-05-03

Verified Specification Summary

Tested under HVI protocols, the Commercial Electric 7130-20-CE exhaust unit achieves 110 CFM at 0.1 in. w.g. (98.4 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones) and delivers 3.9 CFM/W efficacy, covering standard baths up to 98 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Commercial Electric 7130-20-CE Exhaust Fan before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 98.4 CFM

- **Noise @ 0.1"**: 1.5 sones (#412/607)

- **Efficacy Rank**: 3.9 CFM/W (#876/1,145)

- **Static Retention**: 89.5% @ 0.25"

- **Motor Draw**: 28.2 W (10.3 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Commercial Electric 7130-20-CE vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 98.4 CFM out of 110 CFM (89.5% retention, 1.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Commercial Electric 7130-20-CE (series: 7130-20-CE) under PD #3477948 (15 models registered, 2024-05-03). Lighting kit: Yes. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 28.2 watts, about 10.3 kWh/yr (~$1.65/yr at $0.16/kWh) for 1 hr/day shower timers or 247.0 kWh/yr (~$39.52/yr) continuously. Closest competing matches include Akicon AK15110N5-B (110.0 CFM) and Akicon AK15110N5-S (110.0 CFM).

## Where do Commercial Electric 7130-20-CE sones rank across EPA ENERGY STAR fans?

Comparing Commercial Electric 7130-20-CE (1.5 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves Commercial Electric 7130-20-CE CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Commercial Electric 7130-20-CE, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Commercial Electric 7130-20-CE measure up on airflow and noise ratings?

Each row below breaks down Commercial Electric 7130-20-CE certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Commercial Electric (15 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 7130-20-CE / 7130-20-CE | PD ID 3477948 (Qualified 2024-05-03) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (98.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How does ceiling height affect Commercial Electric 7130-20-CE CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Commercial Electric 7130-20-CE

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 98 sq ft | 1 CFM/sq ft @ 98.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 87 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 48 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.3 kWh/yr (~$1.65/yr) | 28.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 247.0 kWh/yr (~$39.52/yr) | 28.2 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Commercial Electric 7130-20-CE?

Compare Commercial Electric 7130-20-CE side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Akicon AK15110N5-B**](https://siematic-charleston.com/ventilation-fans/akicon-ak15110n5-b/) | 110 / 100.5 CFM | 1.5 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| [**Akicon AK15110N5-S**](https://siematic-charleston.com/ventilation-fans/akicon-ak15110n5-s/) | 110 / 100.5 CFM | 1.5 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| [**Akicon AK15110N5-W**](https://siematic-charleston.com/ventilation-fans/akicon-ak15110n5-w/) | 110 / 100.5 CFM | 1.5 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| [**Nutone AERN110RGBL**](https://siematic-charleston.com/ventilation-fans/nutone-aern110rgbl/) | 110 / 97.6 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| [**Nutone AERN110RGBLC**](https://siematic-charleston.com/ventilation-fans/nutone-aern110rgblc/) | 110 / 97.6 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |

## Can you size Commercial Electric 7130-20-CE for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Commercial Electric 7130-20-CE verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Commercial Electric 7130-20-CE suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Commercial Electric 7130-20-CE for your remodel.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 98.4 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Strong scenario:** Target comfort around 1.5 sones up to 98 sq ft
- **Best application:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to Commercial Electric 7130-20-CE?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Commercial Electric 7130-20-CE.

### How many kWh per year does Commercial Electric 7130-20-CE add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Commercial Electric 7130-20-CE averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Commercial Electric 7130-20-CE pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Commercial Electric 7130-20-CE's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Commercial Electric 7130-20-CE?

Commercial Electric 7130-20-CE features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Commercial Electric 7130-20-CE's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Commercial Electric 7130-20-CE's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Commercial Electric 7130-20-CE pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Commercial Electric 7130-20-CE easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install Commercial Electric 7130-20-CE in a bathroom remodel?

Avoid specifying Commercial Electric 7130-20-CE in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut Commercial Electric 7130-20-CE airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Commercial Electric 7130-20-CE achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does Commercial Electric 7130-20-CE occupy in EPA filings?

With 1.5 sones at 0.1 in. w.g., Commercial Electric 7130-20-CE produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

## What neighboring pages and tools support Commercial Electric 7130-20-CE?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Commercial Electric 7130-20-CE.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Commercial Electric BPT14-24OD-H Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/commercial-electric-bpt14-24od-h/)
- [Nutone 791LEDNTM Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/nutone-791ledntm/)
- [Commercial Electric 7130-16-CE Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/commercial-electric-7130-16-ce/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)