title: "Commercial Electric BF1101 Bath Fan (50 CFM, 1.0 Sone)"
url: https://siematic-charleston.com/ventilation-fans/commercial-electric-bf1101/
description: "ENERGY STAR specs for Commercial Electric BF1101: 50 CFM, 1.0 sones (#265 of 607), 5.0 CFM/W, 3 in. diameter and 5 closest peer fans."
---

#  Commercial Electric BF1101 Exhaust Fan Specifications

ENERGY STAR PD #3531174 · Bathroom/Utility Room · Qualified 2024-05-24

Verified Specification Summary

Rated for 50 CFM open-air (45.9 CFM at 0.25 in. w.g.), Commercial Electric BF1101 registers #265 of 607 in quietness (1.0 sones) and delivers 5.0 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 45 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Commercial Electric BF1101 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 50 / 45.9 CFM

- **Noise @ 0.1"**: 1.0 sones (#265/607)

- **Efficacy Rank**: 5.0 CFM/W (#514/1,145)

- **Static Retention**: 91.8% @ 0.25"

- **Motor Draw**: 10.0 W (3.6 kWh/yr)

- **Duct & Tier**: 3 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Commercial Electric BF1101 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 45.9 CFM out of 50 CFM (91.8% retention, 4.1 pts higher retention than the 87.7% median). Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Commercial Electric maintains 15 active ENERGY STAR blowers; BF1101 (series: BF1101) (PD #3531174) gained qualification on 2024-05-24. Lighting kit: No. At 5.0 CFM/W (#514 of 1,145, top 45.2% of 1,145 rated models, more efficient than 54.8% of rated models, 0.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.0 watts, about 3.6 kWh/yr (~$0.58/yr at $0.16/kWh) for 1 hr/day shower timers or 87.6 kWh/yr (~$14.02/yr) continuously. Closest competing matches include RAB CEP8S (50.0 CFM) and Tech Drive FA-BF-01-L (50.0 CFM).

## How does Commercial Electric BF1101 acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Commercial Electric BF1101 (1.0 sones).

## How do flex elbows choke Commercial Electric BF1101 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 3 in. diameter metal pipe keeps Commercial Electric BF1101 moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Commercial Electric BF1101 meet residential exhaust fan code specs?

Inspect Commercial Electric BF1101 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Commercial Electric (15 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | BF1101 / BF1101 | PD ID 3531174 (Qualified 2024-05-24) |
| **Duct Connection** | 3 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | CONTINUOUS ONLY (45.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (1.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Which bathroom duties match Commercial Electric BF1101 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Commercial Electric BF1101 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Commercial Electric BF1101

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 45 sq ft | 1 CFM/sq ft @ 45.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 40 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.6 kWh/yr (~$0.58/yr) | 10.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 87.6 kWh/yr (~$14.02/yr) | 10.0 W x 8,760 hrs / 1,000 |

## Which competing models share Commercial Electric BF1101 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**RAB CEP8S**](https://siematic-charleston.com/ventilation-fans/rab-cep8s/) | 50 / 48.8 CFM | 1.0 sones (Same) | 5.1 CFM/W | 3 in. diameter |
| [**Tech Drive FA-BF-01-L**](https://siematic-charleston.com/ventilation-fans/tech-drive-fa-bf-01-l/) | 50 / 45.1 CFM | 1.0 sones (Same) | 3.8 CFM/W | 3 in. diameter |
| [**MaxLite EBF17-50-1-W**](https://siematic-charleston.com/ventilation-fans/maxlite-ebf17-50-1-w/) | 50 / 49.3 CFM | 1.0 sones (Same) | 3.7 CFM/W | 3 in. diameter |
| [**Air King BFQL50**](https://siematic-charleston.com/ventilation-fans/air-king-bfql50/) | 50 / 39.3 CFM | 0.8 sones (-0.20) | 4.4 CFM/W | 4 in. diameter |
| [**Air King WML50**](https://siematic-charleston.com/ventilation-fans/air-king-wml50/) | 50 / 39.3 CFM | 0.8 sones (-0.20) | 4.4 CFM/W | 4 in. diameter |

## How much airflow margin does Commercial Electric BF1101 give your bath?

Run a quick local room-volume check for Commercial Electric BF1101 by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Commercial Electric BF1101?

Compare where Commercial Electric BF1101 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Bathroom floor <= 45 sq ft with 8-ft ceilings (40 sq ft at 9-ft height)
- **Suited to:** Exterior run uses smooth rigid metal matched to 3 in. diameter

## What should homeowners verify first about Commercial Electric BF1101?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Commercial Electric BF1101.

### Can Commercial Electric BF1101 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Commercial Electric BF1101 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap Commercial Electric BF1101 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Commercial Electric BF1101 lacks adequate reserve.

### How does Commercial Electric BF1101 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Commercial Electric BF1101 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 3 in. diameter rigid metal ducting protects real exhaust.

### Is Commercial Electric BF1101 quiet enough for a primary bedroom bathroom?

At 1.0 sones, Commercial Electric BF1101 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is Commercial Electric BF1101 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Commercial Electric BF1101 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Commercial Electric BF1101's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Commercial Electric BF1101?

Commercial Electric BF1101 features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Commercial Electric BF1101's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Commercial Electric BF1101's safe coverage footprint from 50 sq ft to 44 sq ft.

## Which GradeMark tools pair best with Commercial Electric BF1101?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Commercial Electric BF1101.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Commercial Electric BF1103 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/commercial-electric-bf1103/)
- [Commercial Electric BPT13-12EN Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/commercial-electric-bpt13-12en/)
- [Tuscany 7105-11-M Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/tuscany-7105-11-m/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)