title: "Commercial Electric BF1112 Bath Fan (110 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/commercial-electric-bf1112/
description: "ENERGY STAR specs for Commercial Electric BF1112: 110 CFM, 4.2 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering."
---

#  Commercial Electric BF1112 Exhaust Fan Specifications

ENERGY STAR PD #3531188 · Bathroom/Utility Room · Qualified 2024-05-24

Verified Specification Summary

Certified by EPA ENERGY STAR, Commercial Electric BF1112 delivers 110 CFM free-air (91 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 4.2 CFM/W efficacy, clearing residential IRC M1505 sizing up to 91 sq ft (8-ft height) or 80 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Commercial Electric BF1112 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 91 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.2 CFM/W (#774/1,145)

- **Static Retention**: 82.7% @ 0.25"

- **Motor Draw**: 26.2 W (9.6 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Commercial Electric BF1112 vs. 1,145-Model ENERGY STAR Benchmarks show?

Commercial Electric BF1112 (EPA filing PD #3531188) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 110 CFM open-air to 91 CFM at 0.25 in. w.g. (82.7% retention, 5.0 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Commercial Electric BF1112 (series: BF1112) under PD #3531188 (15 models registered, 2024-05-24). Lighting kit: Yes. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.2 watts, about 9.6 kWh/yr (~$1.54/yr at $0.16/kWh) for 1 hr/day shower timers or 229.5 kWh/yr (~$36.72/yr) continuously. Closest competing matches include Broan AER110LTMB (110.0 CFM) and Broan AER110LTW (110.0 CFM).

## Why does rigid 4 in. diameter ducting protect Commercial Electric BF1112 airflow?

Connecting Commercial Electric BF1112 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Commercial Electric BF1112 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Commercial Electric BF1112 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Commercial Electric (15 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | BF1112 / BF1112 | PD ID 3531188 (Qualified 2024-05-24) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (91 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What room sizes and annual power draw fit Commercial Electric BF1112?

Calculated coverage metrics translate Commercial Electric BF1112 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Commercial Electric BF1112

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 91 sq ft | 1 CFM/sq ft @ 91 CFM |
| Tall Bath (9-ft Ceiling) | Up to 80 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 41 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.6 kWh/yr (~$1.54/yr) | 26.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 229.5 kWh/yr (~$36.72/yr) | 26.2 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Commercial Electric BF1112?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan AER110LTMB**](https://siematic-charleston.com/ventilation-fans/broan-aer110ltmb/) | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**Broan AER110LTW**](https://siematic-charleston.com/ventilation-fans/broan-aer110ltw/) | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**Nutone AER110SLW**](https://siematic-charleston.com/ventilation-fans/nutone-aer110slw/) | 110 / 89.5 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**Nutone AERN110LTK**](https://siematic-charleston.com/ventilation-fans/nutone-aern110ltk/) | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**Nutone AERN110LTW**](https://siematic-charleston.com/ventilation-fans/nutone-aern110ltw/) | 110 / 89.9 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |

## Does Commercial Electric BF1112 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Commercial Electric BF1112 percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Commercial Electric BF1112 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Commercial Electric BF1112 for your remodel.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 41 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Strong scenario:** Moisture load fits 91 CFM net static output
- **Best application:** Collar pairs with 4 in. diameter duct straight outdoors

## Which homeowner questions come up most for Commercial Electric BF1112?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Commercial Electric BF1112.

### How many kWh per year does Commercial Electric BF1112 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Commercial Electric BF1112 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Commercial Electric BF1112 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Commercial Electric BF1112's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Commercial Electric BF1112?

Commercial Electric BF1112 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Commercial Electric BF1112's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Commercial Electric BF1112's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Commercial Electric BF1112 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Commercial Electric BF1112 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install Commercial Electric BF1112 in a bathroom remodel?

Avoid specifying Commercial Electric BF1112 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut Commercial Electric BF1112 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Commercial Electric BF1112 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does Commercial Electric BF1112 occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Commercial Electric BF1112 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

## Where can you explore more benchmarks around Commercial Electric BF1112?

Use the related reference pages and estimators below to cross-check Commercial Electric BF1112 against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Delta 110HLEDNL Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-110hlednl/)
- [Delta ELT50-110 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-elt50-110/)
- [Commercial Electric BF1110 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/commercial-electric-bf1110/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)