title: "Commercial Electric BPT13-14D Bath Fan (80 CFM, 1.5 Sone)"
url: https://siematic-charleston.com/ventilation-fans/commercial-electric-bpt13-14d/
description: "ENERGY STAR specs for Commercial Electric BPT13-14D: 80 CFM, 1.5 sones (#412 of 607), 4.3 CFM/W, 4 in. diameter and 5 closest peer fans."
---

#  Commercial Electric BPT13-14D Exhaust Fan Specifications

ENERGY STAR PD #3531079 · Bathroom/Utility Room · Qualified 2024-05-24

Verified Specification Summary

Certified by EPA ENERGY STAR, Commercial Electric BPT13-14D delivers 80 CFM free-air (57.7 CFM at 0.25 in. w.g.) and registers #412 of 607 in quietness (1.5 sones) and delivers 4.3 CFM/W efficacy, clearing residential IRC M1505 sizing up to 57 sq ft (8-ft height) or 51 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Commercial Electric BPT13-14D Exhaust Fan before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 57.7 CFM

- **Noise @ 0.1"**: 1.5 sones (#412/607)

- **Efficacy Rank**: 4.3 CFM/W (#718/1,145)

- **Static Retention**: 72.1% @ 0.25"

- **Motor Draw**: 18.6 W (6.8 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Commercial Electric BPT13-14D vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 57.7 CFM at 0.25 in. w.g. (72.1% retention, 15.6 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Commercial Electric's 15-unit lineup, BPT13-14D (series: BPT13) carries PD #3531079 dating to 2024-05-24. Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 18.6 watts, about 6.8 kWh/yr (~$1.09/yr at $0.16/kWh) for 1 hr/day shower timers or 162.9 kWh/yr (~$26.06/yr) continuously. Closest competing matches include Air King AK80 (80.0 CFM) and Tech Drive TD-BF-04 (80.0 CFM).

## How noisy is Commercial Electric BPT13-14D compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Commercial Electric BPT13-14D measures 1.5 sones across the 1,145-model registry.

## Why does rigid 4 in. diameter ducting protect Commercial Electric BPT13-14D airflow?

Connecting Commercial Electric BPT13-14D through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Commercial Electric BPT13-14D performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Commercial Electric BPT13-14D lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Commercial Electric (15 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | BPT13-14D / BPT13 | PD ID 3531079 (Qualified 2024-05-24) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (57.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Commercial Electric BPT13-14D?

Calculated coverage metrics translate Commercial Electric BPT13-14D airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Commercial Electric BPT13-14D

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 57 sq ft | 1 CFM/sq ft @ 57.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 51 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.8 kWh/yr (~$1.09/yr) | 18.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 162.9 kWh/yr (~$26.06/yr) | 18.6 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Commercial Electric BPT13-14D?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Air King AK80**](https://siematic-charleston.com/ventilation-fans/air-king-ak80/) | 80 / 68.8 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| [**Tech Drive TD-BF-04**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-04/) | 80 / 57.7 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| [**Tech Drive TD-BF-04-H**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-04-h/) | 80 / 57.7 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| [**Valu+ BPT13-14DT-2**](https://siematic-charleston.com/ventilation-fans/valu-bpt13-14dt-2/) | 80 / 57.7 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| [**VENTECHLATION BPT13-14DT-1**](https://siematic-charleston.com/ventilation-fans/ventechlation-bpt13-14dt-1/) | 80 / 57.7 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |

## Does Commercial Electric BPT13-14D match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Commercial Electric BPT13-14D percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Commercial Electric BPT13-14D?

Match Commercial Electric BPT13-14D directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Best for:** Moisture load fits 57.7 CFM net static output
- **Optimal use:** Collar pairs with 4 in. diameter duct straight outdoors

## Which homeowner questions come up most for Commercial Electric BPT13-14D?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Commercial Electric BPT13-14D.

### What bathroom square footage can Commercial Electric BPT13-14D ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Commercial Electric BPT13-14D covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does Commercial Electric BPT13-14D run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Commercial Electric BPT13-14D.

### What happens to Commercial Electric BPT13-14D CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Commercial Electric BPT13-14D moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

### Where does Commercial Electric BPT13-14D sit on acoustic comfort for senior homeowners?

Measuring 1.5 sones, Commercial Electric BPT13-14D produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does Commercial Electric BPT13-14D cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Commercial Electric BPT13-14D 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Commercial Electric BPT13-14D pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Commercial Electric BPT13-14D's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Commercial Electric BPT13-14D?

Commercial Electric BPT13-14D features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Commercial Electric BPT13-14D's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Commercial Electric BPT13-14D's safe coverage footprint from 50 sq ft to 44 sq ft.

## Where can you explore more benchmarks around Commercial Electric BPT13-14D?

Use the related reference pages and estimators below to cross-check Commercial Electric BPT13-14D against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Commercial Electric BPT13-14HD Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/commercial-electric-bpt13-14hd/)
- [Delta 80F-LED Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-80f-led/)
- [Commercial Electric 7130-18-CE Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/commercial-electric-7130-18-ce/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)