#  COSTWAY BPT14-24A-A-1 Exhaust Fan Specifications

ENERGY STAR PD #3892185 · Bathroom/Utility Room · Qualified 2024-12-20

Verified Specification Summary

Tested under HVI protocols, the COSTWAY BPT14-24A-A-1 exhaust unit achieves 110 CFM at 0.1 in. w.g. (97.5 CFM at 0.25 in. w.g.), registers #380 of 607 in quietness (1.2 sones) and delivers 4.3 CFM/W efficacy, covering standard baths up to 97 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside COSTWAY BPT14-24A-A-1 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 97.5 CFM

- **Noise @ 0.1"**: 1.2 sones (#380/607)

- **Efficacy Rank**: 4.3 CFM/W (#718/1,145)

- **Static Retention**: 88.6% @ 0.25"

- **Motor Draw**: 25.6 W (9.3 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does COSTWAY BPT14-24A-A-1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.2 sones (#380 of 607 rated models, 0.20 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 97.5 CFM out of 110 CFM (88.6% retention, 0.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: COSTWAY registers 2 certified models, with SKU BPT14-24A-A-1 (series: BPT14-24A-A-1) (PD #3892185) certified since 2024-12-20. Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.6 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 224.3 kWh/yr (~$35.89/yr) continuously. Closest competing matches include Nektra 3291028 (110.0 CFM) and Win Air BPT14-24E (110.0 CFM).

## Where do COSTWAY BPT14-24A-A-1 sones rank across EPA ENERGY STAR fans?

Comparing COSTWAY BPT14-24A-A-1 (1.2 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves COSTWAY BPT14-24A-A-1 CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on COSTWAY BPT14-24A-A-1, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does COSTWAY BPT14-24A-A-1 measure up on airflow and noise ratings?

Each row below breaks down COSTWAY BPT14-24A-A-1 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | COSTWAY (2 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | BPT14-24A-A-1 / BPT14-24A-A-1 | PD ID 3892185 (Qualified 2024-12-20) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (97.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.2 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect COSTWAY BPT14-24A-A-1 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for COSTWAY BPT14-24A-A-1

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 97 sq ft | 1 CFM/sq ft @ 97.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 86 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 47 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.3 kWh/yr (~$1.49/yr) | 25.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 224.3 kWh/yr (~$35.89/yr) | 25.6 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against COSTWAY BPT14-24A-A-1?

Compare COSTWAY BPT14-24A-A-1 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Nektra 3291028**](https://siematic-charleston.com/ventilation-fans/nektra-3291028/) | 110 / 98.7 CFM | 1.2 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| [**Win Air BPT14-24E**](https://siematic-charleston.com/ventilation-fans/win-air-bpt14-24e/) | 110 / 98.7 CFM | 1.2 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| [**BV BV-BF-02-PLUS**](https://siematic-charleston.com/ventilation-fans/bv-bv-bf-02-plus/) | 110 / 99 CFM | 1.2 sones (Same) | 4.8 CFM/W | 4 in. diameter |
| [**Valu+ BPT14-24TGHS**](https://siematic-charleston.com/ventilation-fans/valu-bpt14-24tghs/) | 110 / 99 CFM | 1.2 sones (Same) | 4.8 CFM/W | 4 in. diameter |
| [**Anzzi EF-AZ102WH**](https://siematic-charleston.com/ventilation-fans/anzzi-ef-az102wh/) | 110 / 101.4 CFM | 1.3 sones (+0.10) | 4.3 CFM/W | 4 in. diameter |

## Can you size COSTWAY BPT14-24A-A-1 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against COSTWAY BPT14-24A-A-1 verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out COSTWAY BPT14-24A-A-1?

Compare where COSTWAY BPT14-24A-A-1 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 97.5 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Target comfort around 1.2 sones up to 97 sq ft
- **Suited to:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to COSTWAY BPT14-24A-A-1?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for COSTWAY BPT14-24A-A-1.

### Why might a contractor swap COSTWAY BPT14-24A-A-1 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, COSTWAY BPT14-24A-A-1 lacks adequate reserve.

### How does COSTWAY BPT14-24A-A-1 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., COSTWAY BPT14-24A-A-1 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

### Is COSTWAY BPT14-24A-A-1 quiet enough for a primary bedroom bathroom?

At 1.2 sones, COSTWAY BPT14-24A-A-1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is COSTWAY BPT14-24A-A-1 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can COSTWAY BPT14-24A-A-1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from COSTWAY BPT14-24A-A-1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing COSTWAY BPT14-24A-A-1?

COSTWAY BPT14-24A-A-1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change COSTWAY BPT14-24A-A-1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing COSTWAY BPT14-24A-A-1's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can COSTWAY BPT14-24A-A-1 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: COSTWAY BPT14-24A-A-1 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

## What neighboring pages and tools support COSTWAY BPT14-24A-A-1?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around COSTWAY BPT14-24A-A-1.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Nektra 3291028 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/nektra-3291028/)
- [Valu+ BPT14-24TGHS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/valu-bpt14-24tghs/)
- [BV BV-BF-02-PLUS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/bv-bv-bf-02-plus/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)