title: "Cyclone CBP100 Bath Fan (100 CFM, 0.8 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/cyclone-cbp100/
description: "ENERGY STAR specs for Cyclone CBP100: 100 CFM, 0.8 sones (#194 of 607), 4.7 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Cyclone CBP100 Exhaust Fan Specifications

ENERGY STAR PD #2390263 · Bathroom/Utility Room · Qualified 2021-12-10

Verified Specification Summary

The Cyclone CBP100 (CBP) moves 100 CFM at 0.1 in. w.g. (97.3 CFM at 0.25 in. w.g.), registers #194 of 607 in quietness (0.8 sones), and delivers 4.7 CFM/W efficacy, sizing bathrooms up to 97 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Cyclone CBP100 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 97.3 CFM

- **Noise @ 0.1"**: 0.8 sones (#194/607)

- **Efficacy Rank**: 4.7 CFM/W (#545/1,145)

- **Static Retention**: 97.3% @ 0.25"

- **Motor Draw**: 21.3 W (7.8 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Cyclone CBP100 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 97.3 CFM out of 100 CFM (97.3% retention, 9.6 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places CBP100 (series: CBP) (PD #2390263) among 17 Cyclone entries qualified through 2021-12-10. Lighting kit: No. At 4.7 CFM/W (#545 of 1,145, at the median tier among 1,145 rated models; more efficient than 49.6% of rated models, equal to the 4.7 CFM/W median), electrical draw computes to 21.3 watts, about 7.8 kWh/yr (~$1.25/yr at $0.16/kWh) for 1 hr/day shower timers or 186.6 kWh/yr (~$29.86/yr) continuously. Closest competing matches include ACIQ ANP100 (100.0 CFM) and Canarm CNP100 (100.0 CFM).

## Where does Cyclone CBP100 sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 0.8 sones against all 1,145 EPA listings.

## How does duct geometry alter Cyclone CBP100 static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Cyclone CBP100?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Cyclone CBP100 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Cyclone (17 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | CBP100 / CBP | PD ID 2390263 (Qualified 2021-12-10) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (97.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.8 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How much bathroom area can Cyclone CBP100 ventilate safely?

Sizing outputs below convert Cyclone CBP100 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Cyclone CBP100

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 97 sq ft | 1 CFM/sq ft @ 97.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 86 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 47 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.8 kWh/yr (~$1.25/yr) | 21.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 186.6 kWh/yr (~$29.86/yr) | 21.3 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Cyclone CBP100 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**ACIQ ANP100**](https://siematic-charleston.com/ventilation-fans/aciq-anp100/) | 100 / 97.3 CFM | 0.8 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| [**Canarm CNP100**](https://siematic-charleston.com/ventilation-fans/canarm-cnp100/) | 100 / 97.3 CFM | 0.8 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| [**Kaze Appliance SNP100**](https://siematic-charleston.com/ventilation-fans/kaze-appliance-snp100/) | 100 / 97.3 CFM | 0.8 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| [**QuFresh BC100**](https://siematic-charleston.com/ventilation-fans/qufresh-bc100/) | 100 / 97.3 CFM | 0.8 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| [**AUPU B4-10F**](https://siematic-charleston.com/ventilation-fans/aupu-b4-10f/) | 100 / 81.9 CFM | 0.8 sones (Same) | 4.0 CFM/W | 4 in. diameter |

## Will Cyclone CBP100 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Cyclone CBP100 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Cyclone CBP100 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Cyclone CBP100.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 47 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Recommended when:** Bathroom floor <= 97 sq ft with 8-ft ceilings (86 sq ft at 9-ft height)
- **Target scenario:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What key rules and numbers govern Cyclone CBP100?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Cyclone CBP100.

### Which bathroom layouts should pick a larger blower than Cyclone CBP100?

Do not force Cyclone CBP100 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Cyclone CBP100 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Cyclone CBP100 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

### Will Cyclone CBP100 disturb adjacent bedrooms during night use?

Acoustic measurement places Cyclone CBP100 at 0.8 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.

### Does running Cyclone CBP100 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Cyclone CBP100 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Cyclone CBP100 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Cyclone CBP100's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Cyclone CBP100?

Cyclone CBP100 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Cyclone CBP100's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Cyclone CBP100's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Cyclone CBP100 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Cyclone CBP100 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

## Which guides and calculators connect next to Cyclone CBP100?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Cyclone CBP100.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Cyclone CTP100 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/cyclone-ctp100/)
- [Kaze Appliance SNP100 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kaze-appliance-snp100/)
- [Canarm CNP100 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/canarm-cnp100/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)