#  Cyclone CBP80 Exhaust Fan Specifications

ENERGY STAR PD #2390264 · Bathroom/Utility Room · Qualified 2021-12-10

Verified Specification Summary

In EPA dataset 8dv7-nngq, Cyclone CBP80 tests at 80 CFM free discharge (62.6 CFM at 0.25 in. w.g.) and registers #18 of 607 in quietness (0.2 sones) and delivers 4.9 CFM/W efficacy, meeting residential IRC M1505 sizing up to 62 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Cyclone CBP80 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 62.6 CFM

- **Noise @ 0.1"**: 0.2 sones (#18/607)

- **Efficacy Rank**: 4.9 CFM/W (#519/1,145)

- **Static Retention**: 78.2% @ 0.25"

- **Motor Draw**: 16.3 W (5.9 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Cyclone CBP80 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.2 sones (#18 of 607 rated models, quietest 3.8% of 607 rated models, quieter than 96.2% of rated models, 0.80 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 62.6 CFM at 0.25 in. w.g. (78.2% retention, 9.5 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #2390264 verifies CBP80 (series: CBP) under Cyclone (17 listed models, qualified 2021-12-10). Lighting kit: No. At 4.9 CFM/W (#519 of 1,145, top 46.6% of 1,145 rated models, more efficient than 53.4% of rated models, 0.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 16.3 watts, about 5.9 kWh/yr (~$0.94/yr at $0.16/kWh) for 1 hr/day shower timers or 142.8 kWh/yr (~$22.85/yr) continuously. Closest competing matches include Ortech ODC-8003 (80.0 CFM) and QuFresh BC80 (80.0 CFM).

## Does Cyclone CBP80 fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Cyclone CBP80 at 0.2 sones.

## Why avoid unvented attic termination with Cyclone CBP80?

Under ASHRAE 62.2 best practice, Cyclone CBP80 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Cyclone CBP80?

Before cutting ceiling drywall or sizing attic transitions for Cyclone CBP80, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Cyclone (17 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | CBP80 / CBP | PD ID 2390264 (Qualified 2021-12-10) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (62.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.2 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit Cyclone CBP80?

Bathroom ventilation sizing below maps Cyclone CBP80 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Cyclone CBP80

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 62 sq ft | 1 CFM/sq ft @ 62.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 55 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.9 kWh/yr (~$0.94/yr) | 16.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 142.8 kWh/yr (~$22.85/yr) | 16.3 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Cyclone CBP80 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Cyclone CBP80.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Ortech ODC-8003**](https://siematic-charleston.com/ventilation-fans/ortech-odc-8003/) | 80 / 62.6 CFM | 0.2 sones (Same) | 4.9 CFM/W | 4 in. diameter |
| [**QuFresh BC80**](https://siematic-charleston.com/ventilation-fans/qufresh-bc80/) | 80 / 62.6 CFM | 0.2 sones (Same) | 4.9 CFM/W | 4 in. diameter |
| [**Nektra 33003852**](https://siematic-charleston.com/ventilation-fans/nektra-33003852/) | 80 / 68.5 CFM | 0.3 sones (+0.10) | 3.6 CFM/W | 4 in. diameter |
| [**Wintek BPT15B-80H2**](https://siematic-charleston.com/ventilation-fans/wintek-bpt15b-80h2/) | 80 / 68.5 CFM | 0.3 sones (+0.10) | 3.6 CFM/W | 4 in. diameter |
| [**Greenheck SP-A70**](https://siematic-charleston.com/ventilation-fans/greenheck-sp-a70/) | 70 / 54 CFM | 0.1 sones (-0.10) | 5.1 CFM/W | 6 in. diameter |

## What percentage of room demand does Cyclone CBP80 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Cyclone CBP80 tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Cyclone CBP80?

Match Cyclone CBP80 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 62.6 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Best for:** Target comfort around 0.2 sones up to 62 sq ft
- **Optimal use:** Paired with rigid galvanized 4 in. diameter transition

## Where do official rules set limits for Cyclone CBP80?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Cyclone CBP80.

### Where does Cyclone CBP80 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Cyclone CBP80.

### What happens to Cyclone CBP80 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Cyclone CBP80 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

### Where does Cyclone CBP80 sit on acoustic comfort for senior homeowners?

Measuring 0.2 sones, Cyclone CBP80 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does Cyclone CBP80 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Cyclone CBP80 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Cyclone CBP80 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Cyclone CBP80's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Cyclone CBP80?

Cyclone CBP80 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Cyclone CBP80's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Cyclone CBP80's safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can Cyclone CBP80 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Cyclone CBP80 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

## What related resources expand on Cyclone CBP80?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Ortech ODC-8003 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ortech-odc-8003/)
- [QuFresh BC80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/qufresh-bc80/)
- [Greenheck SP-A70 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/greenheck-sp-a70/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)