#  Cyclone CBPD3S100 Exhaust Fan Specifications

ENERGY STAR PD #3550128 · Bathroom/Utility Room · Qualified 2024-06-28

Verified Specification Summary

In EPA dataset 8dv7-nngq, Cyclone CBPD3S100 tests at 100 CFM free discharge (84.7 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 13.2 CFM/W efficacy, meeting residential IRC M1505 sizing up to 84 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Cyclone CBPD3S100 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 84.7 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 13.2 CFM/W (#49/1,145)

- **Static Retention**: 84.7% @ 0.25"

- **Motor Draw**: 7.6 W (2.8 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Most Eff.

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Cyclone CBPD3S100 vs. 1,145-Model ENERGY STAR Benchmarks show?

Cyclone CBPD3S100 (EPA filing PD #3550128) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 100 CFM open-air to 84.7 CFM at 0.25 in. w.g. (84.7% retention, 3.0 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Cyclone CBPD3S100 (series: CBPD) under PD #3550128 (17 models registered, 2024-06-28). Lighting kit: No. At 13.2 CFM/W (#49 of 1,145, top 4.5% of 1,145 rated models, more efficient than 95.5% of rated models, 8.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 7.6 watts, about 2.8 kWh/yr (~$0.45/yr at $0.16/kWh) for 1 hr/day shower timers or 66.6 kWh/yr (~$10.66/yr) continuously. Closest competing matches include Revent RVL110 (110.0 CFM) and Revent RVLH110 (110.0 CFM).

## Why avoid unvented attic termination with Cyclone CBPD3S100?

Under ASHRAE 62.2 best practice, Cyclone CBPD3S100 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Cyclone CBPD3S100?

Before cutting ceiling drywall or sizing attic transitions for Cyclone CBPD3S100, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Cyclone (17 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | CBPD3S100 / CBPD | PD ID 3550128 (Qualified 2024-06-28) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (84.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit Cyclone CBPD3S100?

Bathroom ventilation sizing below maps Cyclone CBPD3S100 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Cyclone CBPD3S100

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 84 sq ft | 1 CFM/sq ft @ 84.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 75 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 34 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.8 kWh/yr (~$0.45/yr) | 7.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 66.6 kWh/yr (~$10.66/yr) | 7.6 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Cyclone CBPD3S100 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Cyclone CBPD3S100.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Revent RVL110**](https://siematic-charleston.com/ventilation-fans/revent-rvl110/) | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| [**Revent RVLH110**](https://siematic-charleston.com/ventilation-fans/revent-rvlh110/) | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| [**DewStop - Breeze Easy BEL110**](https://siematic-charleston.com/ventilation-fans/dewstop-breeze-easy-bel110/) | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |
| [**Revent RVS8090100**](https://siematic-charleston.com/ventilation-fans/revent-rvs8090100/) | 100 / 108.5 CFM | Unpublished | 12.7 CFM/W | 4 in. diameter |
| [**Utilitech UTS8090100**](https://siematic-charleston.com/ventilation-fans/utilitech-uts8090100/) | 100 / 108.5 CFM | Unpublished | 12.7 CFM/W | 4 in. diameter |

## What percentage of room demand does Cyclone CBPD3S100 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Cyclone CBPD3S100 tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Cyclone CBPD3S100 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Cyclone CBPD3S100 for residential use.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 84.7 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Ideal fit:** Target comfort around ENERGY STAR sones up to 84 sq ft
- **Primary match:** Paired with rigid galvanized 4 in. diameter transition

## Where do official rules set limits for Cyclone CBPD3S100?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Cyclone CBPD3S100.

### Why check Cyclone CBPD3S100 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Cyclone CBPD3S100 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

### How does Cyclone CBPD3S100 sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Cyclone CBPD3S100 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Cyclone CBPD3S100?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Cyclone CBPD3S100 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Cyclone CBPD3S100's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Cyclone CBPD3S100?

Cyclone CBPD3S100 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Cyclone CBPD3S100's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Cyclone CBPD3S100's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Cyclone CBPD3S100 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Cyclone CBPD3S100 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Cyclone CBPD3S100 undersized or poorly matched for a bath renovation?

Skip Cyclone CBPD3S100 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

## What related resources expand on Cyclone CBPD3S100?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Cyclone CBPD3S100H Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/cyclone-cbpd3s100h/)
- [Cyclone CTLD100 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/cyclone-ctld100/)
- [CFM TF100-EC Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/cfm-tf100-ec/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)