#  Cyclone CTLD100 Exhaust Fan Specifications

ENERGY STAR PD #2409643 · Bathroom/Utility Room · Qualified 2023-02-03

Verified Specification Summary

Rated for 100 CFM open-air (84.7 CFM at 0.25 in. w.g.), Cyclone CTLD100 omits a published 0.1-inch sone rating and delivers 13.3 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 84 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Cyclone CTLD100 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 84.7 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 13.3 CFM/W (#48/1,145)

- **Static Retention**: 84.7% @ 0.25"

- **Motor Draw**: 7.5 W (2.7 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Most Eff.

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Cyclone CTLD100 vs. 1,145-Model ENERGY STAR Benchmarks show?

Cyclone CTLD100 (EPA filing PD #2409643) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 100 CFM open-air to 84.7 CFM at 0.25 in. w.g. (84.7% retention, 3.0 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Cyclone's 17-unit lineup, CTLD100 (series: CTLD) carries PD #2409643 dating to 2023-02-03. Lighting kit: No. At 13.3 CFM/W (#48 of 1,145, top 4.2% of 1,145 rated models, more efficient than 95.8% of rated models, 8.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 7.5 watts, about 2.7 kWh/yr (~$0.43/yr at $0.16/kWh) for 1 hr/day shower timers or 65.7 kWh/yr (~$10.51/yr) continuously. Closest competing matches include Revent RVL110 (110.0 CFM) and Revent RVLH110 (110.0 CFM).

## How do flex elbows choke Cyclone CTLD100 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Cyclone CTLD100 moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Cyclone CTLD100 meet residential exhaust fan code specs?

Inspect Cyclone CTLD100 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Cyclone (17 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | CTLD100 / CTLD | PD ID 2409643 (Qualified 2023-02-03) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (84.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Which bathroom duties match Cyclone CTLD100 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Cyclone CTLD100 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Cyclone CTLD100

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 84 sq ft | 1 CFM/sq ft @ 84.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 75 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 34 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.7 kWh/yr (~$0.43/yr) | 7.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 65.7 kWh/yr (~$10.51/yr) | 7.5 W x 8,760 hrs / 1,000 |

## Which competing models share Cyclone CTLD100 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Revent RVL110**](https://siematic-charleston.com/ventilation-fans/revent-rvl110/) | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| [**Revent RVLH110**](https://siematic-charleston.com/ventilation-fans/revent-rvlh110/) | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| [**DewStop - Breeze Easy BEL110**](https://siematic-charleston.com/ventilation-fans/dewstop-breeze-easy-bel110/) | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |
| [**Revent RVS8090100**](https://siematic-charleston.com/ventilation-fans/revent-rvs8090100/) | 100 / 108.5 CFM | Unpublished | 12.7 CFM/W | 4 in. diameter |
| [**Utilitech UTS8090100**](https://siematic-charleston.com/ventilation-fans/utilitech-uts8090100/) | 100 / 108.5 CFM | Unpublished | 12.7 CFM/W | 4 in. diameter |

## How much airflow margin does Cyclone CTLD100 give your bath?

Run a quick local room-volume check for Cyclone CTLD100 by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Cyclone CTLD100 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Cyclone CTLD100.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 34 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Recommended when:** Bathroom floor <= 84 sq ft with 8-ft ceilings (75 sq ft at 9-ft height)
- **Target scenario:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What should homeowners verify first about Cyclone CTLD100?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Cyclone CTLD100.

### Will Cyclone CTLD100 disturb adjacent bedrooms during night use?

Acoustic measurement places Cyclone CTLD100 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

### Does running Cyclone CTLD100 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Cyclone CTLD100 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Cyclone CTLD100 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Cyclone CTLD100's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Cyclone CTLD100?

Cyclone CTLD100 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Cyclone CTLD100's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Cyclone CTLD100's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Cyclone CTLD100 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Cyclone CTLD100 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Cyclone CTLD100?

Do not force Cyclone CTLD100 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Cyclone CTLD100 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Cyclone CTLD100 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

## Which GradeMark tools pair best with Cyclone CTLD100?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Cyclone CTLD100.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Revent RVL8090100 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvl8090100/)
- [Revent RVS8090100 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvs8090100/)
- [Cyclone CBPD3S100H Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/cyclone-cbpd3s100h/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)