---
title: "Cyclone ESCBP110 Bath Fan (100 CFM, 1.3 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/cyclone-escbp110-2409640/
description: "ENERGY STAR specs for Cyclone ESCBP110: 100 CFM, 1.3 sones (#397 of 607), 3.8 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency."
---

#  Cyclone ESCBP110 Exhaust Fan Specifications

ENERGY STAR PD #2409640 · Bathroom/Utility Room · Qualified 2023-02-24

Verified Specification Summary

The Cyclone ESCBP110 (ESCBP) moves 100 CFM at 0.1 in. w.g. (82.5 CFM at 0.25 in. w.g.), registers #397 of 607 in quietness (1.3 sones), and delivers 3.8 CFM/W efficacy, sizing bathrooms up to 82 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Cyclone ESCBP110 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 82.5 CFM

- **Noise @ 0.1"**: 1.3 sones (#397/607)

- **Efficacy Rank**: 3.8 CFM/W (#951/1,145)

- **Static Retention**: 82.5% @ 0.25"

- **Motor Draw**: 26.3 W (9.6 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Cyclone ESCBP110 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.3 sones (#397 of 607 rated models, 0.30 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 100 CFM open-air to 82.5 CFM at 0.25 in. w.g. (82.5% retention, 5.2 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #2409640 verifies ESCBP110 (series: ESCBP) under Cyclone (17 listed models, qualified 2023-02-24). Lighting kit: No. At 3.8 CFM/W (#951 of 1,145, below median tier among 1,145 rated models; more efficient than 13.9% of rated models, 0.9 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.3 watts, about 9.6 kWh/yr (~$1.54/yr at $0.16/kWh) for 1 hr/day shower timers or 230.4 kWh/yr (~$36.86/yr) continuously. Closest competing matches include Air King AK110LS (110.0 CFM) and Anzzi EF-AZ102WH (110.0 CFM).

## Where does Cyclone ESCBP110 sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.3 sones against all 1,145 EPA listings.

## How does duct geometry alter Cyclone ESCBP110 static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Cyclone ESCBP110?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Cyclone ESCBP110 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Cyclone (17 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | ESCBP110 / ESCBP | PD ID 2409640 (Qualified 2023-02-24) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (82.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.3 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How much bathroom area can Cyclone ESCBP110 ventilate safely?

Sizing outputs below convert Cyclone ESCBP110 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Cyclone ESCBP110

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 82 sq ft | 1 CFM/sq ft @ 82.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 73 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 32 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.6 kWh/yr (~$1.54/yr) | 26.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 230.4 kWh/yr (~$36.86/yr) | 26.3 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Cyclone ESCBP110 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Air King AK110LS**](https://siematic-charleston.com/ventilation-fans/air-king-ak110ls/) | 110 / 90.7 CFM | 1.3 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| [**Anzzi EF-AZ102WH**](https://siematic-charleston.com/ventilation-fans/anzzi-ef-az102wh/) | 110 / 101.4 CFM | 1.3 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| [**Hunter 90064A**](https://siematic-charleston.com/ventilation-fans/hunter-90064a/) | 100 / 89.6 CFM | 1.5 sones (+0.20) | 3.9 CFM/W | 4 in. diameter |
| [**Hunter 90065A**](https://siematic-charleston.com/ventilation-fans/hunter-90065a/) | 100 / 89.6 CFM | 1.5 sones (+0.20) | 3.9 CFM/W | 4 in. diameter |
| [**Anzzi EF-AZ106MB**](https://siematic-charleston.com/ventilation-fans/anzzi-ef-az106mb/) | 100 / 92.8 CFM | 1.5 sones (+0.20) | 4.0 CFM/W | 4 in. diameter |

## Will Cyclone ESCBP110 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Cyclone ESCBP110 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Cyclone ESCBP110 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Cyclone ESCBP110 carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 32 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Choose this if:** Bathroom floor <= 82 sq ft with 8-ft ceilings (73 sq ft at 9-ft height)
- **Works well for:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What key rules and numbers govern Cyclone ESCBP110?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Cyclone ESCBP110.

### How much power does Cyclone ESCBP110 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Cyclone ESCBP110 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Cyclone ESCBP110 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Cyclone ESCBP110's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Cyclone ESCBP110?

Cyclone ESCBP110 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Cyclone ESCBP110's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Cyclone ESCBP110's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Cyclone ESCBP110 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Cyclone ESCBP110 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Cyclone ESCBP110?

Rule out Cyclone ESCBP110 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke Cyclone ESCBP110 capacity?

Because static drag at 0.25 in. w.g. lowers Cyclone ESCBP110 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is Cyclone ESCBP110 compared with a standard 3.0 sone builder fan?

Tested at 1.3 sones, Cyclone ESCBP110 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

## Which guides and calculators connect next to Cyclone ESCBP110?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Cyclone ESCBP110.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Delta ITG80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-itg80/)
- [Delta ITG80LED Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-itg80led/)
- [Anzzi EF-AZ102WH Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/anzzi-ef-az102wh/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
