#  Cyclone ESLPD3S100 Exhaust Fan Specifications

ENERGY STAR PD #2409637 · Bathroom/Utility Room · Qualified 2023-02-24

Verified Specification Summary

In EPA dataset 8dv7-nngq, Cyclone ESLPD3S100 tests at 100 CFM free discharge (106.5 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 9.3 CFM/W efficacy, meeting residential IRC M1505 sizing up to 106 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Cyclone ESLPD3S100 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 106.5 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 9.3 CFM/W (#258/1,145)

- **Static Retention**: 106.5% @ 0.25"

- **Motor Draw**: 10.8 W (3.9 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Cyclone ESLPD3S100 vs. 1,145-Model ENERGY STAR Benchmarks show?

Cyclone ESLPD3S100 (EPA filing PD #2409637) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 106.5 CFM out of 100 CFM (106.5% retention, 18.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Cyclone ESLPD3S100 (series: ESLPD) under PD #2409637 (17 models registered, 2023-02-24). Lighting kit: No. At 9.3 CFM/W (#258 of 1,145, top 24.5% of 1,145 rated models, more efficient than 75.5% of rated models, 4.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.8 watts, about 3.9 kWh/yr (~$0.62/yr at $0.16/kWh) for 1 hr/day shower timers or 94.6 kWh/yr (~$15.14/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Delta 100HS (100.0 CFM).

## Why avoid unvented attic termination with Cyclone ESLPD3S100?

Under ASHRAE 62.2 best practice, Cyclone ESLPD3S100 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Cyclone ESLPD3S100?

Before cutting ceiling drywall or sizing attic transitions for Cyclone ESLPD3S100, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Cyclone (17 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | ESLPD3S100 / ESLPD | PD ID 2409637 (Qualified 2023-02-24) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (106.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit Cyclone ESLPD3S100?

Bathroom ventilation sizing below maps Cyclone ESLPD3S100 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Cyclone ESLPD3S100

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 106 sq ft | 1 CFM/sq ft @ 106.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 94 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 56 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.9 kWh/yr (~$0.62/yr) | 10.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 94.6 kWh/yr (~$15.14/yr) | 10.8 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Cyclone ESLPD3S100 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Cyclone ESLPD3S100.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Delta GBR100LED-DECOR**](https://siematic-charleston.com/ventilation-fans/delta-gbr100led-decor/) | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| [**Delta 100HS**](https://siematic-charleston.com/ventilation-fans/delta-100hs/) | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| [**Delta ITG100ELED**](https://siematic-charleston.com/ventilation-fans/delta-itg100eled/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Delta ITG100RLED**](https://siematic-charleston.com/ventilation-fans/delta-itg100rled/) | 100 / 89.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## What percentage of room demand does Cyclone ESLPD3S100 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Cyclone ESLPD3S100 tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Cyclone ESLPD3S100 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Cyclone ESLPD3S100 for your remodel.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 106.5 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Strong scenario:** Target comfort around ENERGY STAR sones up to 106 sq ft
- **Best application:** Paired with rigid galvanized 4 in. diameter transition

## Where do official rules set limits for Cyclone ESLPD3S100?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Cyclone ESLPD3S100.

### What acoustic sone tier does Cyclone ESLPD3S100 occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Cyclone ESLPD3S100 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

### How many kWh per year does Cyclone ESLPD3S100 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Cyclone ESLPD3S100 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Cyclone ESLPD3S100 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Cyclone ESLPD3S100's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Cyclone ESLPD3S100?

Cyclone ESLPD3S100 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Cyclone ESLPD3S100's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Cyclone ESLPD3S100's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Cyclone ESLPD3S100 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Cyclone ESLPD3S100 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install Cyclone ESLPD3S100 in a bathroom remodel?

Avoid specifying Cyclone ESLPD3S100 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut Cyclone ESLPD3S100 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Cyclone ESLPD3S100 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

## What related resources expand on Cyclone ESLPD3S100?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Cyclone ESLPD3S100H Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/cyclone-eslpd3s100h/)
- [Delta ELT80-110DLED Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-elt80-110dled-2343280/)
- [COSTWAY BPT16-24ACB Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/costway-bpt16-24acb/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)