---
title: "Dayton 3DPE4B Bath Fan (90 CFM, 0.4 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/dayton-3dpe4b/
description: "ENERGY STAR specs for Dayton 3DPE4B: 90 CFM, 0.4 sones (#50 of 607), 5.5 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Dayton 3DPE4B Exhaust Fan Specifications

ENERGY STAR PD #2335079 · Bathroom/Utility Room · Qualified 2015-10-15

Verified Specification Summary

Rated for 90 CFM open-air (unpublished 0.25 in. w.g. output), Dayton 3DPE4B registers #50 of 607 in quietness (0.4 sones) and delivers 5.5 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 90 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Dayton 3DPE4B Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 90 / N/A CFM

- **Noise @ 0.1"**: 0.4 sones (#50/607)

- **Efficacy Rank**: 5.5 CFM/W (#471/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 16.4 W (6.0 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Dayton 3DPE4B vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Free-discharge delivery reaches 90 CFM (#789 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Dayton maintains 12 active ENERGY STAR blowers; 3DPE4B (series: 3DPE4B) (PD #2335079) gained qualification on 2015-10-15. Lighting kit: No. At 5.5 CFM/W (#471 of 1,145, top 42.8% of 1,145 rated models, more efficient than 57.2% of rated models, 0.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 16.4 watts, about 6.0 kWh/yr (~$0.96/yr at $0.16/kWh) for 1 hr/day shower timers or 143.7 kWh/yr (~$22.99/yr) continuously. Closest competing matches include Greenheck SP-A90 (90.0 CFM) and AERO PURE ABF80G15W (80.0 CFM).

## How does Dayton 3DPE4B acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Dayton 3DPE4B (0.4 sones).

## How do flex elbows choke Dayton 3DPE4B at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Dayton 3DPE4B moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Dayton 3DPE4B meet residential exhaust fan code specs?

Inspect Dayton 3DPE4B mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Dayton (12 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 3DPE4B / 3DPE4B | PD ID 2335079 (Qualified 2015-10-15) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (90 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.4 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Which bathroom duties match Dayton 3DPE4B airflow output?

Annual electricity figures and room square-footage ceilings below reflect Dayton 3DPE4B tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Dayton 3DPE4B

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 90 sq ft | 1 CFM/sq ft @ 90 CFM |
| Tall Bath (9-ft Ceiling) | Up to 80 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 40 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.0 kWh/yr (~$0.96/yr) | 16.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 143.7 kWh/yr (~$22.99/yr) | 16.4 W x 8,760 hrs / 1,000 |

## Which competing models share Dayton 3DPE4B airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Greenheck SP-A90**](https://siematic-charleston.com/ventilation-fans/greenheck-sp-a90/) | 90 / 80 CFM | 0.4 sones (Same) | 5.5 CFM/W | 6 in. diameter |
| [**AERO PURE ABF80G15W**](https://siematic-charleston.com/ventilation-fans/aero-pure-abf80g15w/) | 80 / 62.9 CFM | 0.4 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| [**AERO PURE ABF80G16W**](https://siematic-charleston.com/ventilation-fans/aero-pure-abf80g16w/) | 80 / 62.9 CFM | 0.4 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| [**AUPU AV08A1**](https://siematic-charleston.com/ventilation-fans/aupu-av08a1/) | 80 / 62.9 CFM | 0.4 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| [**Broan QTXEG080**](https://siematic-charleston.com/ventilation-fans/broan-qtxeg080/) | 80 / 85.6 CFM | 0.4 sones (Same) | 4.7 CFM/W | 6 in. diameter |

## How much airflow margin does Dayton 3DPE4B give your bath?

Run a quick local room-volume check for Dayton 3DPE4B by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Dayton 3DPE4B fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Dayton 3DPE4B.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 40 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Recommended when:** Bathroom floor <= 90 sq ft with 8-ft ceilings (80 sq ft at 9-ft height)
- **Target scenario:** Exterior run uses smooth rigid metal matched to 6 in. diameter

## What should homeowners verify first about Dayton 3DPE4B?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Dayton 3DPE4B.

### Will Dayton 3DPE4B disturb adjacent bedrooms during night use?

Acoustic measurement places Dayton 3DPE4B at 0.4 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.

### Does running Dayton 3DPE4B continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Dayton 3DPE4B draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Dayton 3DPE4B pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Dayton 3DPE4B's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Dayton 3DPE4B?

Dayton 3DPE4B features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Dayton 3DPE4B's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Dayton 3DPE4B's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Dayton 3DPE4B code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Dayton 3DPE4B clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Dayton 3DPE4B?

Do not force Dayton 3DPE4B into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Dayton 3DPE4B retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Dayton 3DPE4B produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.

## Which GradeMark tools pair best with Dayton 3DPE4B?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Dayton 3DPE4B.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Greenheck SP-A90 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/greenheck-sp-a90/)
- [AERO PURE ABF80G15W Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aero-pure-abf80g15w/)
- [Nutone RN110 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/nutone-rn110/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
