#  Dayton 3DPE5B Exhaust Fan Specifications

ENERGY STAR PD #2335080 · Bathroom/Utility Room · Qualified 2015-10-15

Verified Specification Summary

The Dayton 3DPE5B (3DPE5B) moves 130 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), registers #135 of 607 in quietness (0.7 sones), and delivers 5.8 CFM/W efficacy, sizing bathrooms up to 130 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Dayton 3DPE5B Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 130 / N/A CFM

- **Noise @ 0.1"**: 0.7 sones (#135/607)

- **Efficacy Rank**: 5.8 CFM/W (#461/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 22.4 W (8.2 kWh/yr)

- **Duct & Tier**: 6 x 8 in. rectangular · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Dayton 3DPE5B vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Free-discharge delivery reaches 130 CFM (#230 of 1,145 certified models) via a 6 x 8 in. rectangular exhaust collar without published 0.25 in. w.g. test points. Use a tight rectangular-to-round galvanized transition off the 6 x 8 in. rectangular housing before entering attic bays.

Manufacturer coverage places 3DPE5B (series: 3DPE5B) (PD #2335080) among 12 Dayton entries qualified through 2015-10-15. Lighting kit: No. At 5.8 CFM/W (#461 of 1,145, top 40.7% of 1,145 rated models, more efficient than 59.3% of rated models, 1.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 22.4 watts, about 8.2 kWh/yr (~$1.31/yr at $0.16/kWh) for 1 hr/day shower timers or 196.2 kWh/yr (~$31.39/yr) continuously. Closest competing matches include Milano TY-130-E (130.0 CFM) and AUPU B6-13 (130.0 CFM).

## Where does Dayton 3DPE5B sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 0.7 sones against all 1,145 EPA listings.

## How does duct geometry alter Dayton 3DPE5B static pressure?

Smooth 6 x 8 in. rectangular galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Dayton 3DPE5B?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Dayton 3DPE5B alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Dayton (12 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 3DPE5B / 3DPE5B | PD ID 2335080 (Qualified 2015-10-15) |
| **Duct Connection** | 6 x 8 in. rectangular | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (130 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.7 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How much bathroom area can Dayton 3DPE5B ventilate safely?

Sizing outputs below convert Dayton 3DPE5B tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Dayton 3DPE5B

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 130 sq ft | 1 CFM/sq ft @ 130 CFM |
| Tall Bath (9-ft Ceiling) | Up to 115 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 80 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.2 kWh/yr (~$1.31/yr) | 22.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 196.2 kWh/yr (~$31.39/yr) | 22.4 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Dayton 3DPE5B closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Milano TY-130-E**](https://siematic-charleston.com/ventilation-fans/milano-ty-130-e/) | 130 / 106.3 CFM | 0.7 sones (Same) | 4.1 CFM/W | 6 in. diameter |
| [**AUPU B6-13**](https://siematic-charleston.com/ventilation-fans/aupu-b6-13/) | 130 / 113.6 CFM | 0.8 sones (+0.10) | 3.9 CFM/W | 4 in. diameter |
| [**AUPU B6-13S**](https://siematic-charleston.com/ventilation-fans/aupu-b6-13s/) | 130 / 113.6 CFM | 0.8 sones (+0.10) | 3.9 CFM/W | 4 in. diameter |
| [**AUPU B6-13L**](https://siematic-charleston.com/ventilation-fans/aupu-b6-13l/) | 130 / 110.2 CFM | 0.8 sones (+0.10) | 3.8 CFM/W | 4 in. diameter |
| [**Ortech OD-1209PB**](https://siematic-charleston.com/ventilation-fans/ortech-od-1209pb/) | 120 / 101.6 CFM | 0.9 sones (+0.20) | 4.3 CFM/W | 6 in. diameter |

## Will Dayton 3DPE5B clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Dayton 3DPE5B satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Dayton 3DPE5B?

Match Dayton 3DPE5B directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 80 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Best for:** Bathroom floor <= 130 sq ft with 8-ft ceilings (115 sq ft at 9-ft height)
- **Optimal use:** Exterior run uses smooth rigid metal matched to 6 x 8 in. rectangular

## What key rules and numbers govern Dayton 3DPE5B?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Dayton 3DPE5B.

### Where does Dayton 3DPE5B run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Dayton 3DPE5B.

### What happens to Dayton 3DPE5B CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Dayton 3DPE5B moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 x 8 in. rectangular collar.

### Where does Dayton 3DPE5B sit on acoustic comfort for senior homeowners?

Measuring 0.7 sones, Dayton 3DPE5B operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does Dayton 3DPE5B cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Dayton 3DPE5B 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Dayton 3DPE5B pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Dayton 3DPE5B's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Dayton 3DPE5B?

Dayton 3DPE5B features a 6 x 8 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Dayton 3DPE5B's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Dayton 3DPE5B's safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can Dayton 3DPE5B ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Dayton 3DPE5B covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

## Which guides and calculators connect next to Dayton 3DPE5B?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Dayton 3DPE5B.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Milano TY-130-E Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/milano-ty-130-e/)
- [AERO PURE ABF110L5W Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aero-pure-abf110l5w/)
- [Revent RVSH150 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvsh150/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)