Verified Specification Summary

Tested under HVI protocols, the Dayton 5AE71 exhaust unit achieves 210 CFM at 0.1 in. w.g. (186 CFM at 0.25 in. w.g.), registers #606 of 607 in quietness (2.4 sones) and delivers 4.2 CFM/W efficacy, covering standard baths up to 186 sq ft on a 6 x 8 in. rectangular collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Dayton 5AE71 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 210 / 186 CFM

- **Noise @ 0.1"**: 2.4 sones (#606/607)

- **Efficacy Rank**: 4.2 CFM/W (#774/1,145)

- **Static Retention**: 88.6% @ 0.25"

- **Motor Draw**: 50.0 W (18.2 kWh/yr)

- **Duct & Tier**: 6 x 8 in. rectangular · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Dayton 5AE71 vs. 1,145-Model ENERGY STAR Benchmarks show?

Utility-grade 2.4 sones acoustic output (#606 of 607 rated models, 1.40 sones louder than the 1.00 sones median), best reserved for powder rooms or laundry alcoves.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 186 CFM out of 210 CFM (88.6% retention, 0.9 pts higher retention than the 87.7% median). Use a tight rectangular-to-round galvanized transition off the 6 x 8 in. rectangular housing before entering attic bays.

Inside Dayton's 12-unit lineup, 5AE71 (series: 5AE71) carries PD #2366110 dating to 2015-10-15. Lighting kit: No. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 50.0 watts, about 18.2 kWh/yr (~$2.91/yr at $0.16/kWh) for 1 hr/day shower timers or 438.0 kWh/yr (~$70.08/yr) continuously. Closest competing matches include Greenheck CSP-A200 (213.0 CFM) and Broan L150E (210.0 CFM).

## Where do Dayton 5AE71 sones rank across EPA ENERGY STAR fans?

Comparing Dayton 5AE71 (2.4 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves Dayton 5AE71 CFM output?

Short straight 6 x 8 in. rectangular duct paths retain up to ~82% of open-air capacity on Dayton 5AE71, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Dayton 5AE71 measure up on airflow and noise ratings?

Each row below breaks down Dayton 5AE71 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Dayton (12 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 5AE71 / 5AE71 | PD ID 2366110 (Qualified 2015-10-15) |
| **Duct Connection** | 6 x 8 in. rectangular | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (186 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (2.4 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect Dayton 5AE71 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Dayton 5AE71

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 186 sq ft | 1 CFM/sq ft @ 186 CFM |
| Tall Bath (9-ft Ceiling) | Up to 165 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 136 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 18.2 kWh/yr (~$2.91/yr) | 50.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 438.0 kWh/yr (~$70.08/yr) | 50.0 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Dayton 5AE71?

Compare Dayton 5AE71 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Greenheck CSP-A200**](https://siematic-charleston.com/ventilation-fans/greenheck-csp-a200/) | 213 / 204 CFM | Unpublished | 3.9 CFM/W | 8 x 6 in. rectangular |
| [**Broan L150E**](https://siematic-charleston.com/ventilation-fans/broan-l150e/) | 210 / 175.2 CFM | Unpublished | 5.0 CFM/W | 8 in. diameter |
| [**Broan L200EL**](https://siematic-charleston.com/ventilation-fans/broan-l200el/) | 200 / N/A CFM | Unpublished | 4.0 CFM/W | 8 in. diameter |
| [**Delta VDBFRS200HT**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200ht/) | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| [**Delta VDBFRS200HT-P**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200ht-p/) | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |

## Can you size Dayton 5AE71 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Dayton 5AE71 verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Dayton 5AE71 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Dayton 5AE71 for your remodel.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 186 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Strong scenario:** Target comfort around 2.4 sones up to 186 sq ft
- **Best application:** Paired with rigid galvanized 6 x 8 in. rectangular transition

## How do federal and code standards apply to Dayton 5AE71?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Dayton 5AE71.

### Who should NOT install Dayton 5AE71 in a bathroom remodel?

Avoid specifying Dayton 5AE71 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut Dayton 5AE71 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Dayton 5AE71 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 x 8 in. rectangular smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does Dayton 5AE71 occupy in EPA filings?

With 2.4 sones at 0.1 in. w.g., Dayton 5AE71 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

### How many kWh per year does Dayton 5AE71 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Dayton 5AE71 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Dayton 5AE71 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Dayton 5AE71's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Dayton 5AE71?

Dayton 5AE71 features a 6 x 8 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Dayton 5AE71's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Dayton 5AE71's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Dayton 5AE71 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Dayton 5AE71 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

## What neighboring pages and tools support Dayton 5AE71?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Dayton 5AE71.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Air King AK280LS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-ak280ls/)
- [Fantech FG 12XL EC Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-fg-12xl-ec/)
- [Greenheck SP-A250 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/greenheck-sp-a250/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)