#  Delta 100HS Exhaust Fan Specifications

ENERGY STAR PD #2326653 · Bathroom/Utility Room · Qualified 2018-09-28

Verified Specification Summary

Tested under HVI protocols, the Delta 100HS exhaust unit achieves 100 CFM at 0.1 in. w.g. (84.1 CFM at 0.25 in. w.g.), registers #405 of 607 in quietness (1.4 sones) and delivers 8.1 CFM/W efficacy, covering standard baths up to 84 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta 100HS Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 84.1 CFM

- **Noise @ 0.1"**: 1.4 sones (#405/607)

- **Efficacy Rank**: 8.1 CFM/W (#338/1,145)

- **Static Retention**: 84.1% @ 0.25"

- **Motor Draw**: 12.3 W (4.5 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Delta 100HS vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.4 sones (#405 of 607 rated models, 0.40 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 100 CFM open-air to 84.1 CFM at 0.25 in. w.g. (84.1% retention, 3.6 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Delta registers 121 certified models, with SKU 100HS (series: BreezGreenBuilder) (PD #2326653) certified since 2018-09-28. Lighting kit: No. At 8.1 CFM/W (#338 of 1,145, top 30.7% of 1,145 rated models, more efficient than 69.3% of rated models, 3.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.3 watts, about 4.5 kWh/yr (~$0.72/yr at $0.16/kWh) for 1 hr/day shower timers or 107.7 kWh/yr (~$17.23/yr) continuously. Closest competing matches include Utilitech 7115-02 (100.0 CFM) and Utilitech 7115-02-BN (100.0 CFM).

## Where do Delta 100HS sones rank across EPA ENERGY STAR fans?

Comparing Delta 100HS (1.4 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves Delta 100HS CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Delta 100HS, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Delta 100HS measure up on airflow and noise ratings?

Each row below breaks down Delta 100HS certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Delta (121 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 100HS / BreezGreenBuilder | PD ID 2326653 (Qualified 2018-09-28) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (84.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.4 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect Delta 100HS CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Delta 100HS

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 84 sq ft | 1 CFM/sq ft @ 84.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 74 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 34 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.5 kWh/yr (~$0.72/yr) | 12.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 107.7 kWh/yr (~$17.23/yr) | 12.3 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Delta 100HS?

Compare Delta 100HS side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech 7115-02**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02/) | 100 / 84.9 CFM | 1.5 sones (+0.10) | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02-BN**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-bn/) | 100 / 84.9 CFM | 1.5 sones (+0.10) | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02-CH**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-ch/) | 100 / 84.9 CFM | 1.5 sones (+0.10) | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02-MB**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-mb/) | 100 / 84.9 CFM | 1.5 sones (+0.10) | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-03**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-03/) | 100 / 89.9 CFM | 1.5 sones (+0.10) | 7.8 CFM/W | 4 in. diameter |

## Can you size Delta 100HS for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Delta 100HS verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Delta 100HS in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Delta 100HS for residential use.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 84.1 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Ideal fit:** Target comfort around 1.4 sones up to 84 sq ft
- **Primary match:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to Delta 100HS?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Delta 100HS.

### Why check Delta 100HS CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Delta 100HS registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

### How does Delta 100HS sound output compare to noisy contractor-grade fans?

Rated at 1.4 sones, Delta 100HS produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Delta 100HS?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Delta 100HS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta 100HS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Delta 100HS?

Delta 100HS features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Delta 100HS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta 100HS's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Delta 100HS satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Delta 100HS clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Delta 100HS undersized or poorly matched for a bath renovation?

Skip Delta 100HS if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

## What neighboring pages and tools support Delta 100HS?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Delta 100HS.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Delta GBR100 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-gbr100/)
- [Broan ALT4306SS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-alt4306ss/)
- [Delta 100F Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-100f/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)