---
title: "Delta 100LED Bath Fan (100 CFM, 1.5 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/delta-100led/
description: "ENERGY STAR specs for Delta 100LED: 100 CFM, 1.5 sones (#412 of 607), 7.4 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Delta 100LED Exhaust Fan Specifications

ENERGY STAR PD #2361940 · Bathroom/Utility Room · Qualified 2020-06-08

Verified Specification Summary

The Delta 100LED (BreezGreenBuilder) moves 100 CFM at 0.1 in. w.g. (75 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones), and delivers 7.4 CFM/W efficacy, sizing bathrooms up to 75 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta 100LED Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 75 CFM

- **Noise @ 0.1"**: 1.5 sones (#412/607)

- **Efficacy Rank**: 7.4 CFM/W (#392/1,145)

- **Static Retention**: 75.0% @ 0.25"

- **Motor Draw**: 13.5 W (4.9 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Delta 100LED vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 100 CFM open-air to 75 CFM at 0.25 in. w.g. (75.0% retention, 12.7 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Delta registers 121 certified models, with SKU 100LED (series: BreezGreenBuilder) (PD #2361940) certified since 2020-06-08. Lighting kit: Yes. At 7.4 CFM/W (#392 of 1,145, top 34.8% of 1,145 rated models, more efficient than 65.2% of rated models, 2.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 13.5 watts, about 4.9 kWh/yr (~$0.78/yr at $0.16/kWh) for 1 hr/day shower timers or 118.3 kWh/yr (~$18.93/yr) continuously. Closest competing matches include Utilitech 7131-04 (100.0 CFM) and Utilitech 7115-02 (100.0 CFM).

## Where does Delta 100LED sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.5 sones against all 1,145 EPA listings.

## How does duct geometry alter Delta 100LED static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Delta 100LED?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Delta 100LED alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Delta (121 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 100LED / BreezGreenBuilder | PD ID 2361940 (Qualified 2020-06-08) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (75 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How much bathroom area can Delta 100LED ventilate safely?

Sizing outputs below convert Delta 100LED tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Delta 100LED

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 75 sq ft | 1 CFM/sq ft @ 75 CFM |
| Tall Bath (9-ft Ceiling) | Up to 66 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 25 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.9 kWh/yr (~$0.78/yr) | 13.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 118.3 kWh/yr (~$18.93/yr) | 13.5 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Delta 100LED closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech 7131-04**](https://siematic-charleston.com/ventilation-fans/utilitech-7131-04/) | 100 / 88 CFM | 1.5 sones (Same) | 7.6 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02/) | 100 / 84.9 CFM | 1.5 sones (Same) | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02-BN**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-bn/) | 100 / 84.9 CFM | 1.5 sones (Same) | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02-CH**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-ch/) | 100 / 84.9 CFM | 1.5 sones (Same) | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02-MB**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-mb/) | 100 / 84.9 CFM | 1.5 sones (Same) | 7.8 CFM/W | 4 in. diameter |

## Will Delta 100LED clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Delta 100LED satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Delta 100LED?

Match Delta 100LED directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 25 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Best for:** Bathroom floor <= 75 sq ft with 8-ft ceilings (66 sq ft at 9-ft height)
- **Optimal use:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What key rules and numbers govern Delta 100LED?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Delta 100LED.

### Where does Delta 100LED sit on acoustic comfort for senior homeowners?

Measuring 1.5 sones, Delta 100LED produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does Delta 100LED cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Delta 100LED 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Delta 100LED pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta 100LED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Delta 100LED?

Delta 100LED features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Delta 100LED's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta 100LED's safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can Delta 100LED ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Delta 100LED covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does Delta 100LED run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Delta 100LED.

### What happens to Delta 100LED CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Delta 100LED moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

## Which guides and calculators connect next to Delta 100LED?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Delta 100LED.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Delta GBR100LED Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-gbr100led/)
- [Delta GBR100LED-DECOR Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-gbr100led-decor/)
- [CFM TF100N Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/cfm-tf100n/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
