title: "Delta 70BT Bath Fan (70 CFM, 1.0 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/delta-70bt/
description: "ENERGY STAR specs for Delta 70BT: 70 CFM, 1.0 sones (#265 of 607), 10.6 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Delta 70BT Exhaust Fan Specifications

ENERGY STAR PD #2274029 · Bathroom/Utility Room · Qualified 2016-08-01

Verified Specification Summary

Tested under HVI protocols, the Delta 70BT exhaust unit achieves 70 CFM at 0.1 in. w.g. (60 CFM at 0.25 in. w.g.), registers #265 of 607 in quietness (1.0 sones) and delivers 10.6 CFM/W efficacy, covering standard baths up to 60 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta 70BT Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 70 / 60 CFM

- **Noise @ 0.1"**: 1.0 sones (#265/607)

- **Efficacy Rank**: 10.6 CFM/W (#152/1,145)

- **Static Retention**: 85.7% @ 0.25"

- **Motor Draw**: 6.6 W (2.4 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Most Eff.

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Delta 70BT vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 60 CFM out of 70 CFM (85.7% retention, 2.0 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Delta 70BT (series: BreezSlim) under PD #2274029 (121 models registered, 2016-08-01). Lighting kit: No. At 10.6 CFM/W (#152 of 1,145, top 13.7% of 1,145 rated models, more efficient than 86.3% of rated models, 5.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 6.6 watts, about 2.4 kWh/yr (~$0.38/yr at $0.16/kWh) for 1 hr/day shower timers or 57.8 kWh/yr (~$9.25/yr) continuously. Closest competing matches include Delta ITG70BT (70.0 CFM) and Revent RVL80 (80.0 CFM).

## Where do Delta 70BT sones rank across EPA ENERGY STAR fans?

Comparing Delta 70BT (1.0 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves Delta 70BT CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Delta 70BT, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Delta 70BT measure up on airflow and noise ratings?

Each row below breaks down Delta 70BT certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Delta (121 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 70BT / BreezSlim | PD ID 2274029 (Qualified 2016-08-01) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (60 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (1.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect Delta 70BT CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Delta 70BT

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 60 sq ft | 1 CFM/sq ft @ 60 CFM |
| Tall Bath (9-ft Ceiling) | Up to 53 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.4 kWh/yr (~$0.38/yr) | 6.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 57.8 kWh/yr (~$9.25/yr) | 6.6 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Delta 70BT?

Compare Delta 70BT side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Delta ITG70BT**](https://siematic-charleston.com/ventilation-fans/delta-itg70bt/) | 70 / 60 CFM | 1.0 sones (Same) | 10.6 CFM/W | 4 in. diameter |
| [**Revent RVL80**](https://siematic-charleston.com/ventilation-fans/revent-rvl80/) | 80 / 89 CFM | 0.8 sones (-0.20) | 12.0 CFM/W | 4 in. diameter |
| [**Hampton Bay 7114-02**](https://siematic-charleston.com/ventilation-fans/hampton-bay-7114-02/) | 50 / 36.9 CFM | 1.0 sones (Same) | 10.2 CFM/W | 3 in. diameter |
| [**HomeWerks Worldwide 7114-02-HW**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7114-02-hw/) | 50 / 36.9 CFM | 1.0 sones (Same) | 10.2 CFM/W | 3 in. diameter |
| [**Utilitech 7114-02-L**](https://siematic-charleston.com/ventilation-fans/utilitech-7114-02-l/) | 50 / 36.9 CFM | 1.0 sones (Same) | 10.2 CFM/W | 3 in. diameter |

## Can you size Delta 70BT for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Delta 70BT verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Delta 70BT on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Delta 70BT carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 60 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Choose this if:** Target comfort around 1.0 sones up to 60 sq ft
- **Works well for:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to Delta 70BT?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Delta 70BT.

### How loud is Delta 70BT compared with a standard 3.0 sone builder fan?

Tested at 1.0 sones, Delta 70BT operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Delta 70BT consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Delta 70BT draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Delta 70BT pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta 70BT's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Delta 70BT?

Delta 70BT features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Delta 70BT's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta 70BT's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Delta 70BT score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Delta 70BT delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Delta 70BT?

Rule out Delta 70BT when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke Delta 70BT capacity?

Because static drag at 0.25 in. w.g. lowers Delta 70BT from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

## What neighboring pages and tools support Delta 70BT?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Delta 70BT.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Delta ITG70BT Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-itg70bt/)
- [Delta 50F Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-50f/)
- [DewStop - Breeze Easy BES110 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/dewstop-breeze-easy-bes110/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)