title: "Delta 70HS Bath Fan (70 CFM, 2.0 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/delta-70hs/
description: "ENERGY STAR specs for Delta 70HS: 70 CFM, 2.0 sones (#522 of 607), 5.8 CFM/W, 3 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Delta 70HS Exhaust Fan Specifications

ENERGY STAR PD #2268999 · Bathroom/Utility Room · Qualified 2016-06-03

Verified Specification Summary

Rated for 70 CFM open-air (58.7 CFM at 0.25 in. w.g.), Delta 70HS registers #522 of 607 in quietness (2.0 sones) and delivers 5.8 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 58 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta 70HS Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 70 / 58.7 CFM

- **Noise @ 0.1"**: 2.0 sones (#522/607)

- **Efficacy Rank**: 5.8 CFM/W (#461/1,145)

- **Static Retention**: 83.9% @ 0.25"

- **Motor Draw**: 12.1 W (4.4 kWh/yr)

- **Duct & Tier**: 3 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Delta 70HS vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 70 CFM open-air to 58.7 CFM at 0.25 in. w.g. (83.9% retention, 3.8 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Delta 70HS (series: BreezSlim) under PD #2268999 (121 models registered, 2016-06-03). Lighting kit: No. At 5.8 CFM/W (#461 of 1,145, top 40.7% of 1,145 rated models, more efficient than 59.3% of rated models, 1.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.1 watts, about 4.4 kWh/yr (~$0.70/yr at $0.16/kWh) for 1 hr/day shower timers or 106.0 kWh/yr (~$16.96/yr) continuously. Closest competing matches include Utilitech 7111-04-L (70.0 CFM) and Revent RVL70 (70.0 CFM).

## How does Delta 70HS acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Delta 70HS (2.0 sones).

## How do flex elbows choke Delta 70HS at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 3 in. diameter metal pipe keeps Delta 70HS moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Delta 70HS meet residential exhaust fan code specs?

Inspect Delta 70HS mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Delta (121 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 70HS / BreezSlim | PD ID 2268999 (Qualified 2016-06-03) |
| **Duct Connection** | 3 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (58.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (2.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Which bathroom duties match Delta 70HS airflow output?

Annual electricity figures and room square-footage ceilings below reflect Delta 70HS tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Delta 70HS

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 58 sq ft | 1 CFM/sq ft @ 58.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 52 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.4 kWh/yr (~$0.70/yr) | 12.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 106.0 kWh/yr (~$16.96/yr) | 12.1 W x 8,760 hrs / 1,000 |

## Which competing models share Delta 70HS airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech 7111-04-L**](https://siematic-charleston.com/ventilation-fans/utilitech-7111-04-l/) | 70 / 56.5 CFM | 2.0 sones (Same) | 7.0 CFM/W | 3 in. diameter |
| [**Revent RVL70**](https://siematic-charleston.com/ventilation-fans/revent-rvl70/) | 70 / 72.3 CFM | 2.0 sones (Same) | 7.7 CFM/W | 4 in. diameter |
| [**Revent RVLH70**](https://siematic-charleston.com/ventilation-fans/revent-rvlh70/) | 70 / 72.3 CFM | 2.0 sones (Same) | 7.7 CFM/W | 4 in. diameter |
| [**Broan BEL7A**](https://siematic-charleston.com/ventilation-fans/broan-bel7a/) | 70 / 57.4 CFM | 2.0 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| [**HomeWerks Worldwide 299650A**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-299650a/) | 70 / 58.9 CFM | 2.0 sones (Same) | 3.8 CFM/W | 3 in. diameter |

## How much airflow margin does Delta 70HS give your bath?

Run a quick local room-volume check for Delta 70HS by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Delta 70HS?

Compare where Delta 70HS excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Bathroom floor <= 58 sq ft with 8-ft ceilings (52 sq ft at 9-ft height)
- **Suited to:** Exterior run uses smooth rigid metal matched to 3 in. diameter

## What should homeowners verify first about Delta 70HS?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Delta 70HS.

### Is Delta 70HS quiet enough for a primary bedroom bathroom?

At 2.0 sones, Delta 70HS produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is Delta 70HS energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Delta 70HS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta 70HS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Delta 70HS?

Delta 70HS features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Delta 70HS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta 70HS's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Delta 70HS serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Delta 70HS supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap Delta 70HS for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Delta 70HS lacks adequate reserve.

### How does Delta 70HS handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Delta 70HS yields unlisted 0.25 in. w.g. backpressure figures, so smooth 3 in. diameter rigid metal ducting protects real exhaust.

## Which GradeMark tools pair best with Delta 70HS?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Delta 70HS.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Delta SLM70ELED Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-slm70eled/)
- [Delta SLM70H Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-slm70h/)
- [Delta 70F Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-70f/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)