title: "Delta 80HLED Bath Fan (80 CFM, 0.8 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/delta-80hled/
description: "ENERGY STAR specs for Delta 80HLED: 80 CFM, 0.8 sones (#194 of 607), 7.3 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Delta 80HLED Exhaust Fan Specifications

ENERGY STAR PD #2389094 · Bathroom/Utility Room · Qualified 2021-10-15

Verified Specification Summary

Tested under HVI protocols, the Delta 80HLED exhaust unit achieves 80 CFM at 0.1 in. w.g. (64.4 CFM at 0.25 in. w.g.), registers #194 of 607 in quietness (0.8 sones) and delivers 7.3 CFM/W efficacy, covering standard baths up to 64 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta 80HLED Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 64.4 CFM

- **Noise @ 0.1"**: 0.8 sones (#194/607)

- **Efficacy Rank**: 7.3 CFM/W (#400/1,145)

- **Static Retention**: 80.5% @ 0.25"

- **Motor Draw**: 11.0 W (4.0 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Delta 80HLED vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 64.4 CFM at 0.25 in. w.g. (80.5% retention, 7.2 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Delta's 121-unit lineup, 80HLED (series: BreezGreenBuilder) carries PD #2389094 dating to 2021-10-15. Lighting kit: Yes. At 7.3 CFM/W (#400 of 1,145, top 35.5% of 1,145 rated models, more efficient than 64.5% of rated models, 2.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.0 watts, about 4.0 kWh/yr (~$0.64/yr at $0.16/kWh) for 1 hr/day shower timers or 96.4 kWh/yr (~$15.42/yr) continuously. Closest competing matches include Anzzi EF-AZ101WH (80.0 CFM) and Aria QBV0800 (80.0 CFM).

## Where do Delta 80HLED sones rank across EPA ENERGY STAR fans?

Comparing Delta 80HLED (0.8 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves Delta 80HLED CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Delta 80HLED, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Delta 80HLED measure up on airflow and noise ratings?

Each row below breaks down Delta 80HLED certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Delta (121 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 80HLED / BreezGreenBuilder | PD ID 2389094 (Qualified 2021-10-15) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (64.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.8 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How does ceiling height affect Delta 80HLED CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Delta 80HLED

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 64 sq ft | 1 CFM/sq ft @ 64.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 57 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.0 kWh/yr (~$0.64/yr) | 11.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 96.4 kWh/yr (~$15.42/yr) | 11.0 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Delta 80HLED?

Compare Delta 80HLED side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Anzzi EF-AZ101WH**](https://siematic-charleston.com/ventilation-fans/anzzi-ef-az101wh/) | 80 / 68.9 CFM | 0.7 sones (-0.10) | 5.3 CFM/W | 4 in. diameter |
| [**Aria QBV0800**](https://siematic-charleston.com/ventilation-fans/aria-qbv0800/) | 80 / 68.9 CFM | 0.7 sones (-0.10) | 5.3 CFM/W | 4 in. diameter |
| [**Haier QVE801DTWW**](https://siematic-charleston.com/ventilation-fans/haier-qve801dtww/) | 80 / 68.9 CFM | 0.7 sones (-0.10) | 5.3 CFM/W | 4 in. diameter |
| [**Delta 80LED-ADJ**](https://siematic-charleston.com/ventilation-fans/delta-80led-adj/) | 80 / 64.4 CFM | 0.8 sones (Same) | 7.3 CFM/W | 4 in. diameter |
| [**Delta GBR80LED**](https://siematic-charleston.com/ventilation-fans/delta-gbr80led/) | 80 / 64.4 CFM | 0.8 sones (Same) | 7.3 CFM/W | 4 in. diameter |

## Can you size Delta 80HLED for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Delta 80HLED verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Delta 80HLED on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Delta 80HLED carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 64.4 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Choose this if:** Target comfort around 0.8 sones up to 64 sq ft
- **Works well for:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to Delta 80HLED?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Delta 80HLED.

### How much power does Delta 80HLED consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Delta 80HLED draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Delta 80HLED pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta 80HLED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Delta 80HLED?

Delta 80HLED features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Delta 80HLED's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta 80HLED's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Delta 80HLED score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Delta 80HLED delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Delta 80HLED?

Rule out Delta 80HLED when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke Delta 80HLED capacity?

Because static drag at 0.25 in. w.g. lowers Delta 80HLED from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is Delta 80HLED compared with a standard 3.0 sone builder fan?

Tested at 0.8 sones, Delta 80HLED operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

## What neighboring pages and tools support Delta 80HLED?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Delta 80HLED.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Delta 80LED-ADJ Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-80led-adj/)
- [Delta GBR80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-gbr80/)
- [Delta 80F-DGL Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-80f-dgl/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)