ENERGY STAR PD #2374797 · Bathroom/Utility Room · Qualified 2021-03-12

Verified Specification Summary

Tested under HVI protocols, the Delta 80RLED-ADJ-BN exhaust unit achieves 80 CFM at 0.1 in. w.g. (62.9 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones) and delivers 7.2 CFM/W efficacy, covering standard baths up to 62 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta 80RLED-ADJ-BN Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 62.9 CFM

- **Noise @ 0.1"**: 1.5 sones (#412/607)

- **Efficacy Rank**: 7.2 CFM/W (#407/1,145)

- **Static Retention**: 78.6% @ 0.25"

- **Motor Draw**: 11.1 W (4.1 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Delta 80RLED-ADJ-BN vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 62.9 CFM at 0.25 in. w.g. (78.6% retention, 9.1 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places 80RLED-ADJ-BN (series: BreezIntegrity) (PD #2374797) among 121 Delta entries qualified through 2021-03-12. Lighting kit: Yes. At 7.2 CFM/W (#407 of 1,145, top 36.2% of 1,145 rated models, more efficient than 63.8% of rated models, 2.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.1 watts, about 4.1 kWh/yr (~$0.66/yr at $0.16/kWh) for 1 hr/day shower timers or 97.2 kWh/yr (~$15.55/yr) continuously. Closest competing matches include Utilitech 7142-70-L (70.0 CFM) and Delta 80F-LED (80.0 CFM).

## Where do Delta 80RLED-ADJ-BN sones rank across EPA ENERGY STAR fans?

Comparing Delta 80RLED-ADJ-BN (1.5 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves Delta 80RLED-ADJ-BN CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Delta 80RLED-ADJ-BN, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Delta 80RLED-ADJ-BN measure up on airflow and noise ratings?

Each row below breaks down Delta 80RLED-ADJ-BN certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Delta (121 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 80RLED-ADJ-BN / BreezIntegrity | PD ID 2374797 (Qualified 2021-03-12) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (62.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How does ceiling height affect Delta 80RLED-ADJ-BN CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Delta 80RLED-ADJ-BN

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 62 sq ft | 1 CFM/sq ft @ 62.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 55 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.1 kWh/yr (~$0.66/yr) | 11.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 97.2 kWh/yr (~$15.55/yr) | 11.1 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Delta 80RLED-ADJ-BN?

Compare Delta 80RLED-ADJ-BN side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech 7142-70-L**](https://siematic-charleston.com/ventilation-fans/utilitech-7142-70-l/) | 70 / 55.5 CFM | 1.5 sones (Same) | 7.2 CFM/W | 3 in. diameter |
| [**Delta 80F-LED**](https://siematic-charleston.com/ventilation-fans/delta-80f-led/) | 80 / 61.5 CFM | 1.5 sones (Same) | 7.2 CFM/W | 4 in. diameter |
| [**Delta 80RLED-ADJ**](https://siematic-charleston.com/ventilation-fans/delta-80rled-adj/) | 80 / 62.9 CFM | 1.5 sones (Same) | 7.2 CFM/W | 4 in. diameter |
| [**Delta 80RLED-ADJ-MB**](https://siematic-charleston.com/ventilation-fans/delta-80rled-adj-mb/) | 80 / 62.9 CFM | 1.5 sones (Same) | 7.2 CFM/W | 4 in. diameter |
| [**Delta ITG80RLED-ADJ**](https://siematic-charleston.com/ventilation-fans/delta-itg80rled-adj/) | 80 / 62.9 CFM | 1.5 sones (Same) | 7.2 CFM/W | 4 in. diameter |

## Can you size Delta 80RLED-ADJ-BN for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Delta 80RLED-ADJ-BN verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Delta 80RLED-ADJ-BN on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Delta 80RLED-ADJ-BN carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 62.9 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Choose this if:** Target comfort around 1.5 sones up to 62 sq ft
- **Works well for:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to Delta 80RLED-ADJ-BN?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Delta 80RLED-ADJ-BN.

### How loud is Delta 80RLED-ADJ-BN compared with a standard 3.0 sone builder fan?

Tested at 1.5 sones, Delta 80RLED-ADJ-BN produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Delta 80RLED-ADJ-BN consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Delta 80RLED-ADJ-BN draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Delta 80RLED-ADJ-BN pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta 80RLED-ADJ-BN's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Delta 80RLED-ADJ-BN?

Delta 80RLED-ADJ-BN features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Delta 80RLED-ADJ-BN's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta 80RLED-ADJ-BN's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Delta 80RLED-ADJ-BN score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Delta 80RLED-ADJ-BN delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Delta 80RLED-ADJ-BN?

Rule out Delta 80RLED-ADJ-BN when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke Delta 80RLED-ADJ-BN capacity?

Because static drag at 0.25 in. w.g. lowers Delta 80RLED-ADJ-BN from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

## What neighboring pages and tools support Delta 80RLED-ADJ-BN?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Delta 80RLED-ADJ-BN.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Delta 80RLED-ADJ-MB Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-80rled-adj-mb/)
- [Delta ITG80RLED-ADJ Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-itg80rled-adj/)
- [Delta 80RLED-ADJ Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-80rled-adj/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)