title: "Delta ELT50-110MHLED Bath Fan (110 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/delta-elt50-110mhled/
description: "ENERGY STAR specs for Delta ELT50-110MHLED: 110 CFM, 9.6 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes."
---

#  Delta ELT50-110MHLED Exhaust Fan Specifications

ENERGY STAR PD #4619018 · Bathroom/Utility Room · Qualified 2026-03-25

Verified Specification Summary

The Delta ELT50-110MHLED (BreezElite) moves 110 CFM at 0.1 in. w.g. (113.7 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 9.6 CFM/W efficacy, sizing bathrooms up to 113 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta ELT50-110MHLED Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 113.7 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 9.6 CFM/W (#206/1,145)

- **Static Retention**: 103.4% @ 0.25"

- **Motor Draw**: 11.5 W (4.2 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Delta ELT50-110MHLED vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta ELT50-110MHLED (EPA filing PD #4619018) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 113.7 CFM out of 110 CFM (103.4% retention, 15.7 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Delta ELT50-110MHLED (series: BreezElite) under PD #4619018 (121 models registered, 2026-03-25). Lighting kit: Yes. At 9.6 CFM/W (#206 of 1,145, top 20.3% of 1,145 rated models, more efficient than 79.7% of rated models, 4.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.5 watts, about 4.2 kWh/yr (~$0.67/yr at $0.16/kWh) for 1 hr/day shower timers or 100.7 kWh/yr (~$16.11/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

## How does duct geometry alter Delta ELT50-110MHLED static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Delta ELT50-110MHLED?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Delta ELT50-110MHLED alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Delta (121 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | ELT50-110MHLED / BreezElite | PD ID 4619018 (Qualified 2026-03-25) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (113.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How much bathroom area can Delta ELT50-110MHLED ventilate safely?

Sizing outputs below convert Delta ELT50-110MHLED tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Delta ELT50-110MHLED

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 113 sq ft | 1 CFM/sq ft @ 113.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 101 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 63 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.2 kWh/yr (~$0.67/yr) | 11.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 100.7 kWh/yr (~$16.11/yr) | 11.5 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Delta ELT50-110MHLED closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02-BN**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-bn/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02-CH**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-ch/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## Will Delta ELT50-110MHLED clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Delta ELT50-110MHLED satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Delta ELT50-110MHLED in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Delta ELT50-110MHLED for residential use.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 63 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Ideal fit:** Bathroom floor <= 113 sq ft with 8-ft ceilings (101 sq ft at 9-ft height)
- **Primary match:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What key rules and numbers govern Delta ELT50-110MHLED?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Delta ELT50-110MHLED.

### How does Delta ELT50-110MHLED sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Delta ELT50-110MHLED produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Delta ELT50-110MHLED?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Delta ELT50-110MHLED pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta ELT50-110MHLED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Delta ELT50-110MHLED?

Delta ELT50-110MHLED features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Delta ELT50-110MHLED's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta ELT50-110MHLED's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Delta ELT50-110MHLED satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Delta ELT50-110MHLED clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Delta ELT50-110MHLED undersized or poorly matched for a bath renovation?

Skip Delta ELT50-110MHLED if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Delta ELT50-110MHLED CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Delta ELT50-110MHLED registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

## Which guides and calculators connect next to Delta ELT50-110MHLED?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Delta ELT50-110MHLED.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Delta ELT80-110 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-elt80-110/)
- [Delta ELT80-110 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-elt80-110-2343265/)
- [Delta ELT50-110MH Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-elt50-110mh/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)