Verified Specification Summary

Rated for 110 CFM open-air (93.7 CFM at 0.25 in. w.g.), Delta ELT80-110 omits a published 0.1-inch sone rating and delivers 9.2 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 93 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta ELT80-110 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 93.7 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 9.2 CFM/W (#282/1,145)

- **Static Retention**: 85.2% @ 0.25"

- **Motor Draw**: 12.0 W (4.4 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Delta ELT80-110 vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta ELT80-110 (EPA filing PD #2343265) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 93.7 CFM out of 110 CFM (85.2% retention, 2.5 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Delta registers 121 certified models, with SKU ELT80-110 (series: BreezElite) (PD #2343265) certified since 2018-12-21. Lighting kit: No. At 9.2 CFM/W (#282 of 1,145, top 25.4% of 1,145 rated models, more efficient than 74.6% of rated models, 4.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.0 watts, about 4.4 kWh/yr (~$0.70/yr at $0.16/kWh) for 1 hr/day shower timers or 105.1 kWh/yr (~$16.82/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

## How do flex elbows choke Delta ELT80-110 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Delta ELT80-110 moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Delta ELT80-110 meet residential exhaust fan code specs?

Inspect Delta ELT80-110 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Delta (121 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | ELT80-110 / BreezElite | PD ID 2343265 (Qualified 2018-12-21) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (93.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Which bathroom duties match Delta ELT80-110 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Delta ELT80-110 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Delta ELT80-110

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 93 sq ft | 1 CFM/sq ft @ 93.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 83 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 43 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.4 kWh/yr (~$0.70/yr) | 12.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 105.1 kWh/yr (~$16.82/yr) | 12.0 W x 8,760 hrs / 1,000 |

## Which competing models share Delta ELT80-110 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02-BN**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-bn/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02-CH**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-ch/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## How much airflow margin does Delta ELT80-110 give your bath?

Run a quick local room-volume check for Delta ELT80-110 by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Delta ELT80-110?

Compare where Delta ELT80-110 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 43 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Bathroom floor <= 93 sq ft with 8-ft ceilings (83 sq ft at 9-ft height)
- **Suited to:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What should homeowners verify first about Delta ELT80-110?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Delta ELT80-110.

### Why might a contractor swap Delta ELT80-110 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Delta ELT80-110 lacks adequate reserve.

### How does Delta ELT80-110 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Delta ELT80-110 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

### Is Delta ELT80-110 quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Delta ELT80-110 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is Delta ELT80-110 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Delta ELT80-110 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta ELT80-110's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Delta ELT80-110?

Delta ELT80-110 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Delta ELT80-110's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta ELT80-110's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Delta ELT80-110 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Delta ELT80-110 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

## Which GradeMark tools pair best with Delta ELT80-110?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Delta ELT80-110.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Delta ELT80-110D Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-elt80-110d/)
- [Delta ELT80-110D Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-elt80-110d-2343267/)
- [Delta ELT80-110 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-elt80-110/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)