---
title: "Delta ELT80-110H Bath Fan (110 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/delta-elt80-110h/
description: "ENERGY STAR specs for Delta ELT80-110H: 110 CFM, 9.2 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes, and."
---

#  Delta ELT80-110H Exhaust Fan Specifications

ENERGY STAR PD #2343268 · Bathroom/Utility Room · Qualified 2018-12-21

Verified Specification Summary

Tested under HVI protocols, the Delta ELT80-110H exhaust unit achieves 110 CFM at 0.1 in. w.g. (93.7 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 9.2 CFM/W efficacy, covering standard baths up to 93 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta ELT80-110H Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 93.7 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 9.2 CFM/W (#282/1,145)

- **Static Retention**: 85.2% @ 0.25"

- **Motor Draw**: 12.0 W (4.4 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Delta ELT80-110H vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta ELT80-110H (EPA filing PD #2343268) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 93.7 CFM out of 110 CFM (85.2% retention, 2.5 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Delta's 121-unit lineup, ELT80-110H (series: BreezElite) carries PD #2343268 dating to 2018-12-21. Lighting kit: No. At 9.2 CFM/W (#282 of 1,145, top 25.4% of 1,145 rated models, more efficient than 74.6% of rated models, 4.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.0 watts, about 4.4 kWh/yr (~$0.70/yr at $0.16/kWh) for 1 hr/day shower timers or 105.1 kWh/yr (~$16.82/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

## What attic duct routing preserves Delta ELT80-110H CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Delta ELT80-110H, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Delta ELT80-110H measure up on airflow and noise ratings?

Each row below breaks down Delta ELT80-110H certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Delta (121 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | ELT80-110H / BreezElite | PD ID 2343268 (Qualified 2018-12-21) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (93.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect Delta ELT80-110H CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Delta ELT80-110H

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 93 sq ft | 1 CFM/sq ft @ 93.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 83 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 43 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.4 kWh/yr (~$0.70/yr) | 12.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 105.1 kWh/yr (~$16.82/yr) | 12.0 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Delta ELT80-110H?

Compare Delta ELT80-110H side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02-BN**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-bn/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02-CH**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-ch/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## Can you size Delta ELT80-110H for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Delta ELT80-110H verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Delta ELT80-110H fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Delta ELT80-110H.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 93.7 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Recommended when:** Target comfort around ENERGY STAR sones up to 93 sq ft
- **Target scenario:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to Delta ELT80-110H?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Delta ELT80-110H.

### Does running Delta ELT80-110H continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Delta ELT80-110H draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Delta ELT80-110H pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta ELT80-110H's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Delta ELT80-110H?

Delta ELT80-110H features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Delta ELT80-110H's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta ELT80-110H's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Delta ELT80-110H code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Delta ELT80-110H clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Delta ELT80-110H?

Do not force Delta ELT80-110H into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Delta ELT80-110H retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Delta ELT80-110H produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

### Will Delta ELT80-110H disturb adjacent bedrooms during night use?

Acoustic measurement places Delta ELT80-110H at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

## What neighboring pages and tools support Delta ELT80-110H?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Delta ELT80-110H.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Delta ELT80-110H Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-elt80-110h-2343269/)
- [Delta ELT80-110HLED Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-elt80-110hled/)
- [Delta ELT80-110DLED Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-elt80-110dled/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
