---
title: "Delta ELT80-110LED Bath Fan (110 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/delta-elt80-110led/
description: "ENERGY STAR specs for Delta ELT80-110LED: 110 CFM, 11.9 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes."
---

#  Delta ELT80-110LED Exhaust Fan Specifications

ENERGY STAR PD #2343277 · Bathroom/Utility Room · Qualified 2018-12-21

Verified Specification Summary

Rated for 110 CFM open-air (92.3 CFM at 0.25 in. w.g.), Delta ELT80-110LED omits a published 0.1-inch sone rating and delivers 11.9 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 92 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta ELT80-110LED Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 92.3 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 11.9 CFM/W (#85/1,145)

- **Static Retention**: 83.9% @ 0.25"

- **Motor Draw**: 9.2 W (3.4 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Delta ELT80-110LED vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta ELT80-110LED (EPA filing PD #2343277) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 110 CFM open-air to 92.3 CFM at 0.25 in. w.g. (83.9% retention, 3.8 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Certification audit confirms Delta ELT80-110LED (series: BreezElite) under PD #2343277 (121 models registered, 2018-12-21). Lighting kit: Yes. At 11.9 CFM/W (#85 of 1,145, top 7.8% of 1,145 rated models, more efficient than 92.2% of rated models, 7.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.2 watts, about 3.4 kWh/yr (~$0.54/yr at $0.16/kWh) for 1 hr/day shower timers or 80.6 kWh/yr (~$12.90/yr) continuously. Closest competing matches include Revent RVL110 (110.0 CFM) and Revent RVLH110 (110.0 CFM).

## How do flex elbows choke Delta ELT80-110LED at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Delta ELT80-110LED moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Delta ELT80-110LED meet residential exhaust fan code specs?

Inspect Delta ELT80-110LED mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Delta (121 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | ELT80-110LED / BreezElite | PD ID 2343277 (Qualified 2018-12-21) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (92.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## Which bathroom duties match Delta ELT80-110LED airflow output?

Annual electricity figures and room square-footage ceilings below reflect Delta ELT80-110LED tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Delta ELT80-110LED

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 92 sq ft | 1 CFM/sq ft @ 92.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 82 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 42 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.4 kWh/yr (~$0.54/yr) | 9.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 80.6 kWh/yr (~$12.90/yr) | 9.2 W x 8,760 hrs / 1,000 |

## Which competing models share Delta ELT80-110LED airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Revent RVL110**](https://siematic-charleston.com/ventilation-fans/revent-rvl110/) | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| [**Revent RVLH110**](https://siematic-charleston.com/ventilation-fans/revent-rvlh110/) | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| [**DewStop - Breeze Easy BEL110**](https://siematic-charleston.com/ventilation-fans/dewstop-breeze-easy-bel110/) | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Loren Cook Company GCVF 100**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gcvf-100/) | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |

## How much airflow margin does Delta ELT80-110LED give your bath?

Run a quick local room-volume check for Delta ELT80-110LED by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Delta ELT80-110LED on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Delta ELT80-110LED carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 42 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Choose this if:** Bathroom floor <= 92 sq ft with 8-ft ceilings (82 sq ft at 9-ft height)
- **Works well for:** Exterior run uses smooth rigid metal matched to 6 in. diameter

## What should homeowners verify first about Delta ELT80-110LED?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Delta ELT80-110LED.

### How loud is Delta ELT80-110LED compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Delta ELT80-110LED produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Delta ELT80-110LED consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Delta ELT80-110LED draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Delta ELT80-110LED pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta ELT80-110LED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Delta ELT80-110LED?

Delta ELT80-110LED features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Delta ELT80-110LED's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta ELT80-110LED's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Delta ELT80-110LED score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Delta ELT80-110LED delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Delta ELT80-110LED?

Rule out Delta ELT80-110LED when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke Delta ELT80-110LED capacity?

Because static drag at 0.25 in. w.g. lowers Delta ELT80-110LED from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.

## Which GradeMark tools pair best with Delta ELT80-110LED?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Delta ELT80-110LED.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Delta ELT80-110MH Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-elt80-110mh/)
- [Delta ELT80-110MH Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-elt80-110mh-2343271/)
- [Delta ELT80-110HLED Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-elt80-110hled/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
