title: "Delta GBR100LED-DECOR Bath Fan (100 CFM, 1.5 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/delta-gbr100led-decor/
description: "ENERGY STAR specs for Delta GBR100LED-DECOR: 100 CFM, 1.5 sones (#412 of 607), 8.4 CFM/W, 4 in. diameter and 5 closest peer fans."
---

#  Delta GBR100LED-DECOR Exhaust Fan Specifications

ENERGY STAR PD #2343237 · Bathroom/Utility Room · Qualified 2016-05-04

Verified Specification Summary

Tested under HVI protocols, the Delta GBR100LED-DECOR exhaust unit achieves 100 CFM at 0.1 in. w.g. (75 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones) and delivers 8.4 CFM/W efficacy, covering standard baths up to 75 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta GBR100LED-DECOR Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 75 CFM

- **Noise @ 0.1"**: 1.5 sones (#412/607)

- **Efficacy Rank**: 8.4 CFM/W (#317/1,145)

- **Static Retention**: 75.0% @ 0.25"

- **Motor Draw**: 11.9 W (4.3 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Delta GBR100LED-DECOR vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 100 CFM open-air to 75 CFM at 0.25 in. w.g. (75.0% retention, 12.7 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Delta's 121-unit lineup, GBR100LED-DECOR (series: BreezGreenBuilder) carries PD #2343237 dating to 2016-05-04. Lighting kit: Yes. At 8.4 CFM/W (#317 of 1,145, top 27.9% of 1,145 rated models, more efficient than 72.1% of rated models, 3.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.9 watts, about 4.3 kWh/yr (~$0.69/yr at $0.16/kWh) for 1 hr/day shower timers or 104.2 kWh/yr (~$16.67/yr) continuously. Closest competing matches include Utilitech 7115-02 (100.0 CFM) and Utilitech 7115-02-BN (100.0 CFM).

## Where do Delta GBR100LED-DECOR sones rank across EPA ENERGY STAR fans?

Comparing Delta GBR100LED-DECOR (1.5 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves Delta GBR100LED-DECOR CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Delta GBR100LED-DECOR, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Delta GBR100LED-DECOR measure up on airflow and noise ratings?

Each row below breaks down Delta GBR100LED-DECOR certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Delta (121 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | GBR100LED-DECOR / BreezGreenBuilder | PD ID 2343237 (Qualified 2016-05-04) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (75 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How does ceiling height affect Delta GBR100LED-DECOR CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Delta GBR100LED-DECOR

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 75 sq ft | 1 CFM/sq ft @ 75 CFM |
| Tall Bath (9-ft Ceiling) | Up to 66 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 25 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.3 kWh/yr (~$0.69/yr) | 11.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 104.2 kWh/yr (~$16.67/yr) | 11.9 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Delta GBR100LED-DECOR?

Compare Delta GBR100LED-DECOR side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech 7115-02**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02/) | 100 / 84.9 CFM | 1.5 sones (Same) | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02-BN**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-bn/) | 100 / 84.9 CFM | 1.5 sones (Same) | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02-CH**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-ch/) | 100 / 84.9 CFM | 1.5 sones (Same) | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02-MB**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-mb/) | 100 / 84.9 CFM | 1.5 sones (Same) | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-03**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-03/) | 100 / 89.9 CFM | 1.5 sones (Same) | 7.8 CFM/W | 4 in. diameter |

## Can you size Delta GBR100LED-DECOR for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Delta GBR100LED-DECOR verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Delta GBR100LED-DECOR in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Delta GBR100LED-DECOR for residential use.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 75 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Ideal fit:** Target comfort around 1.5 sones up to 75 sq ft
- **Primary match:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to Delta GBR100LED-DECOR?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Delta GBR100LED-DECOR.

### Does Delta GBR100LED-DECOR satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Delta GBR100LED-DECOR clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Delta GBR100LED-DECOR undersized or poorly matched for a bath renovation?

Skip Delta GBR100LED-DECOR if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Delta GBR100LED-DECOR CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Delta GBR100LED-DECOR registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

### How does Delta GBR100LED-DECOR sound output compare to noisy contractor-grade fans?

Rated at 1.5 sones, Delta GBR100LED-DECOR produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Delta GBR100LED-DECOR?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Delta GBR100LED-DECOR pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta GBR100LED-DECOR's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Delta GBR100LED-DECOR?

Delta GBR100LED-DECOR features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Delta GBR100LED-DECOR's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta GBR100LED-DECOR's safe coverage footprint from 50 sq ft to 44 sq ft.

## What neighboring pages and tools support Delta GBR100LED-DECOR?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Delta GBR100LED-DECOR.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Delta ITG100 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-itg100/)
- [Delta ITG100ELED Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-itg100eled/)
- [Delta GBR100LED Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-gbr100led/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)