title: "Delta ITG80 Bath Fan (80 CFM, 1.3 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/delta-itg80/
description: "ENERGY STAR specs for Delta ITG80: 80 CFM, 1.3 sones (#397 of 607), 8.4 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Delta ITG80 Exhaust Fan Specifications

ENERGY STAR PD #2312828 · Bathroom/Utility Room · Qualified 2018-03-16

Verified Specification Summary

In EPA dataset 8dv7-nngq, Delta ITG80 tests at 80 CFM free discharge (68.3 CFM at 0.25 in. w.g.) and registers #397 of 607 in quietness (1.3 sones) and delivers 8.4 CFM/W efficacy, meeting residential IRC M1505 sizing up to 68 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta ITG80 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 68.3 CFM

- **Noise @ 0.1"**: 1.3 sones (#397/607)

- **Efficacy Rank**: 8.4 CFM/W (#317/1,145)

- **Static Retention**: 85.4% @ 0.25"

- **Motor Draw**: 9.5 W (3.5 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Delta ITG80 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.3 sones (#397 of 607 rated models, 0.30 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 68.3 CFM out of 80 CFM (85.4% retention, 2.3 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Delta's 121-unit lineup, ITG80 (series: BreezIntegrity) carries PD #2312828 dating to 2018-03-16. Lighting kit: No. At 8.4 CFM/W (#317 of 1,145, top 27.9% of 1,145 rated models, more efficient than 72.1% of rated models, 3.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.5 watts, about 3.5 kWh/yr (~$0.56/yr at $0.16/kWh) for 1 hr/day shower timers or 83.2 kWh/yr (~$13.31/yr) continuously. Closest competing matches include HomeWerks Worldwide 7130-40-BT (90.0 CFM) and Utilitech 7142-70-L (70.0 CFM).

## Does Delta ITG80 fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Delta ITG80 at 1.3 sones.

## Why avoid unvented attic termination with Delta ITG80?

Under ASHRAE 62.2 best practice, Delta ITG80 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Delta ITG80?

Before cutting ceiling drywall or sizing attic transitions for Delta ITG80, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Delta (121 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | ITG80 / BreezIntegrity | PD ID 2312828 (Qualified 2018-03-16) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (68.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.3 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit Delta ITG80?

Bathroom ventilation sizing below maps Delta ITG80 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Delta ITG80

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 68 sq ft | 1 CFM/sq ft @ 68.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 60 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.5 kWh/yr (~$0.56/yr) | 9.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 83.2 kWh/yr (~$13.31/yr) | 9.5 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Delta ITG80 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Delta ITG80.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**HomeWerks Worldwide 7130-40-BT**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7130-40-bt/) | 90 / 84.3 CFM | 1.2 sones (-0.10) | 7.7 CFM/W | 4 in. diameter |
| [**Utilitech 7142-70-L**](https://siematic-charleston.com/ventilation-fans/utilitech-7142-70-l/) | 70 / 55.5 CFM | 1.5 sones (+0.20) | 7.2 CFM/W | 3 in. diameter |
| [**Delta ITG80LED**](https://siematic-charleston.com/ventilation-fans/delta-itg80led/) | 80 / 61.5 CFM | 1.3 sones (Same) | 7.2 CFM/W | 4 in. diameter |
| [**Delta VFB080B4A1-LVDC**](https://siematic-charleston.com/ventilation-fans/delta-vfb080b4a1-lvdc/) | 80 / 61.9 CFM | 1.5 sones (+0.20) | 7.8 CFM/W | 4 in. diameter |
| [**Delta 80F-LED**](https://siematic-charleston.com/ventilation-fans/delta-80f-led/) | 80 / 61.5 CFM | 1.5 sones (+0.20) | 7.2 CFM/W | 4 in. diameter |

## What percentage of room demand does Delta ITG80 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Delta ITG80 tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Delta ITG80 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Delta ITG80 carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 68.3 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Choose this if:** Target comfort around 1.3 sones up to 68 sq ft
- **Works well for:** Paired with rigid galvanized 4 in. diameter transition

## Where do official rules set limits for Delta ITG80?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Delta ITG80.

### Will long attic ducting choke Delta ITG80 capacity?

Because static drag at 0.25 in. w.g. lowers Delta ITG80 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is Delta ITG80 compared with a standard 3.0 sone builder fan?

Tested at 1.3 sones, Delta ITG80 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Delta ITG80 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Delta ITG80 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Delta ITG80 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta ITG80's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Delta ITG80?

Delta ITG80 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Delta ITG80's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta ITG80's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Delta ITG80 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Delta ITG80 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Delta ITG80?

Rule out Delta ITG80 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

## What related resources expand on Delta ITG80?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Delta ITG80LED Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-itg80led/)
- [Broan (Canada) EZ80C Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-canada-ez80c/)
- [Cyclone ESCBP110 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/cyclone-escbp110-2409640/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)