#  Delta ITG80H Exhaust Fan Specifications

ENERGY STAR PD #2388363 · Bathroom/Utility Room · Qualified 2021-11-19

Verified Specification Summary

Tested under HVI protocols, the Delta ITG80H exhaust unit achieves 80 CFM at 0.1 in. w.g. (64.6 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 9.0 CFM/W efficacy, covering standard baths up to 64 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta ITG80H Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 64.6 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 9.0 CFM/W (#298/1,145)

- **Static Retention**: 80.7% @ 0.25"

- **Motor Draw**: 8.9 W (3.2 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Delta ITG80H vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta ITG80H (EPA filing PD #2388363) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 64.6 CFM at 0.25 in. w.g. (80.7% retention, 7.0 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places ITG80H (series: BreezIntegrity) (PD #2388363) among 121 Delta entries qualified through 2021-11-19. Lighting kit: No. At 9.0 CFM/W (#298 of 1,145, top 26.1% of 1,145 rated models, more efficient than 73.9% of rated models, 4.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 8.9 watts, about 3.2 kWh/yr (~$0.51/yr at $0.16/kWh) for 1 hr/day shower timers or 78.0 kWh/yr (~$12.48/yr) continuously. Closest competing matches include Utilitech 7142-70-L (70.0 CFM) and Delta VFB080B4A1-LVDC (80.0 CFM).

## What attic duct routing preserves Delta ITG80H CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Delta ITG80H, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Delta ITG80H measure up on airflow and noise ratings?

Each row below breaks down Delta ITG80H certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Delta (121 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | ITG80H / BreezIntegrity | PD ID 2388363 (Qualified 2021-11-19) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (64.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect Delta ITG80H CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Delta ITG80H

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 64 sq ft | 1 CFM/sq ft @ 64.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 57 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.2 kWh/yr (~$0.51/yr) | 8.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 78.0 kWh/yr (~$12.48/yr) | 8.9 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Delta ITG80H?

Compare Delta ITG80H side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech 7142-70-L**](https://siematic-charleston.com/ventilation-fans/utilitech-7142-70-l/) | 70 / 55.5 CFM | 1.5 sones | 7.2 CFM/W | 3 in. diameter |
| [**Delta VFB080B4A1-LVDC**](https://siematic-charleston.com/ventilation-fans/delta-vfb080b4a1-lvdc/) | 80 / 61.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Delta ITG80**](https://siematic-charleston.com/ventilation-fans/delta-itg80/) | 80 / 68.3 CFM | 1.3 sones | 8.4 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02-BN**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-bn/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## Can you size Delta ITG80H for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Delta ITG80H verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Delta ITG80H on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Delta ITG80H carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 64.6 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Choose this if:** Target comfort around ENERGY STAR sones up to 64 sq ft
- **Works well for:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to Delta ITG80H?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Delta ITG80H.

### Will long attic ducting choke Delta ITG80H capacity?

Because static drag at 0.25 in. w.g. lowers Delta ITG80H from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is Delta ITG80H compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Delta ITG80H produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Delta ITG80H consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Delta ITG80H draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Delta ITG80H pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta ITG80H's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Delta ITG80H?

Delta ITG80H features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Delta ITG80H's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta ITG80H's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Delta ITG80H score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Delta ITG80H delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Delta ITG80H?

Rule out Delta ITG80H when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

## What neighboring pages and tools support Delta ITG80H?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Delta ITG80H.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Delta SIG80D Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-sig80d/)
- [Nutone 744RNL Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/nutone-744rnl/)
- [Delta GBR80HLED Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-gbr80hled/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)