---
title: "Delta ITG80LED Bath Fan (80 CFM, 1.3 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/delta-itg80led/
description: "ENERGY STAR specs for Delta ITG80LED: 80 CFM, 1.3 sones (#397 of 607), 7.2 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Delta ITG80LED Exhaust Fan Specifications

ENERGY STAR PD #2279592 · Bathroom/Utility Room · Qualified 2016-09-15

Verified Specification Summary

Rated for 80 CFM open-air (61.5 CFM at 0.25 in. w.g.), Delta ITG80LED registers #397 of 607 in quietness (1.3 sones) and delivers 7.2 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 61 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta ITG80LED Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 61.5 CFM

- **Noise @ 0.1"**: 1.3 sones (#397/607)

- **Efficacy Rank**: 7.2 CFM/W (#407/1,145)

- **Static Retention**: 76.9% @ 0.25"

- **Motor Draw**: 11.1 W (4.1 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Delta ITG80LED vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.3 sones (#397 of 607 rated models, 0.30 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 61.5 CFM at 0.25 in. w.g. (76.9% retention, 10.8 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Delta maintains 121 active ENERGY STAR blowers; ITG80LED (series: BreezIntegrity) (PD #2279592) gained qualification on 2016-09-15. Lighting kit: Yes. At 7.2 CFM/W (#407 of 1,145, top 36.2% of 1,145 rated models, more efficient than 63.8% of rated models, 2.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.1 watts, about 4.1 kWh/yr (~$0.66/yr at $0.16/kWh) for 1 hr/day shower timers or 97.2 kWh/yr (~$15.55/yr) continuously. Closest competing matches include HomeWerks Worldwide 7130-40-BT (90.0 CFM) and Utilitech 7142-70-L (70.0 CFM).

## How does Delta ITG80LED acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Delta ITG80LED (1.3 sones).

## How do flex elbows choke Delta ITG80LED at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Delta ITG80LED moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Delta ITG80LED meet residential exhaust fan code specs?

Inspect Delta ITG80LED mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Delta (121 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | ITG80LED / BreezIntegrity | PD ID 2279592 (Qualified 2016-09-15) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (61.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.3 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## Which bathroom duties match Delta ITG80LED airflow output?

Annual electricity figures and room square-footage ceilings below reflect Delta ITG80LED tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Delta ITG80LED

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 61 sq ft | 1 CFM/sq ft @ 61.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 54 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.1 kWh/yr (~$0.66/yr) | 11.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 97.2 kWh/yr (~$15.55/yr) | 11.1 W x 8,760 hrs / 1,000 |

## Which competing models share Delta ITG80LED airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**HomeWerks Worldwide 7130-40-BT**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7130-40-bt/) | 90 / 84.3 CFM | 1.2 sones (-0.10) | 7.7 CFM/W | 4 in. diameter |
| [**Utilitech 7142-70-L**](https://siematic-charleston.com/ventilation-fans/utilitech-7142-70-l/) | 70 / 55.5 CFM | 1.5 sones (+0.20) | 7.2 CFM/W | 3 in. diameter |
| [**Fantech RCS80L**](https://siematic-charleston.com/ventilation-fans/fantech-rcs80l/) | 80 / 80.4 CFM | 1.2 sones (-0.10) | 5.1 CFM/W | 4 in. diameter |
| [**S&P PCLP80**](https://siematic-charleston.com/ventilation-fans/s-p-pclp80/) | 80 / 68.3 CFM | 1.2 sones (-0.10) | 4.7 CFM/W | 4 in. diameter |
| [**Delta ITG80**](https://siematic-charleston.com/ventilation-fans/delta-itg80/) | 80 / 68.3 CFM | 1.3 sones (Same) | 8.4 CFM/W | 4 in. diameter |

## How much airflow margin does Delta ITG80LED give your bath?

Run a quick local room-volume check for Delta ITG80LED by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Delta ITG80LED suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Delta ITG80LED for your remodel.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Strong scenario:** Bathroom floor <= 61 sq ft with 8-ft ceilings (54 sq ft at 9-ft height)
- **Best application:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What should homeowners verify first about Delta ITG80LED?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Delta ITG80LED.

### Does Delta ITG80LED pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Delta ITG80LED easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install Delta ITG80LED in a bathroom remodel?

Avoid specifying Delta ITG80LED in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut Delta ITG80LED airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Delta ITG80LED achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does Delta ITG80LED occupy in EPA filings?

With 1.3 sones at 0.1 in. w.g., Delta ITG80LED produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

### How many kWh per year does Delta ITG80LED add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Delta ITG80LED averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Delta ITG80LED pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta ITG80LED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Delta ITG80LED?

Delta ITG80LED features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Delta ITG80LED's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta ITG80LED's safe coverage footprint from 50 sq ft to 44 sq ft.

## Which GradeMark tools pair best with Delta ITG80LED?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Delta ITG80LED.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan (Canada) EZ80C Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-canada-ez80c/)
- [Nutone LPN80=LP80HwithLPN80F Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/nutone-lpn80-lp80hwithlpn80f/)
- [Delta ITG80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-itg80/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
