---
title: "Delta Pro300 Bath Fan (300 CFM, 2.0 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/delta-pro300/
description: "ENERGY STAR specs for Delta Pro300: 300 CFM, 2.0 sones (#522 of 607), 7.4 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Delta Pro300 Exhaust Fan Specifications

ENERGY STAR PD #2254292 · Bathroom/Utility Room · Qualified 2015-12-01

Verified Specification Summary

The Delta Pro300 (BreezPro) moves 300 CFM at 0.1 in. w.g. (271.3 CFM at 0.25 in. w.g.), registers #522 of 607 in quietness (2.0 sones), and delivers 7.4 CFM/W efficacy, sizing bathrooms up to 271 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta Pro300 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 300 / 271.3 CFM

- **Noise @ 0.1"**: 2.0 sones (#522/607)

- **Efficacy Rank**: 7.4 CFM/W (#392/1,145)

- **Static Retention**: 90.4% @ 0.25"

- **Motor Draw**: 40.5 W (14.8 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Delta Pro300 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 271.3 CFM out of 300 CFM (90.4% retention, 2.7 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside Delta's 121-unit lineup, Pro300 (series: BreezPro) carries PD #2254292 dating to 2015-12-01. Lighting kit: No. At 7.4 CFM/W (#392 of 1,145, top 34.8% of 1,145 rated models, more efficient than 65.2% of rated models, 2.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 40.5 watts, about 14.8 kWh/yr (~$2.37/yr at $0.16/kWh) for 1 hr/day shower timers or 354.8 kWh/yr (~$56.77/yr) continuously. Closest competing matches include Delta VDB200 (200.0 CFM) and Delta VDBFRS200 (200.0 CFM).

## Where does Delta Pro300 sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 2.0 sones against all 1,145 EPA listings.

## How does duct geometry alter Delta Pro300 static pressure?

Smooth 6 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Delta Pro300?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Delta Pro300 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Delta (121 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | Pro300 / BreezPro | PD ID 2254292 (Qualified 2015-12-01) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (271.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (2.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How much bathroom area can Delta Pro300 ventilate safely?

Sizing outputs below convert Delta Pro300 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Delta Pro300

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 271 sq ft | 1 CFM/sq ft @ 271.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 241 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 221 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 14.8 kWh/yr (~$2.37/yr) | 40.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 354.8 kWh/yr (~$56.77/yr) | 40.5 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Delta Pro300 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Delta VDB200**](https://siematic-charleston.com/ventilation-fans/delta-vdb200/) | 200 / N/A CFM | Unpublished | 6.6 CFM/W | 6 in. diameter |
| [**Delta VDBFRS200**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200/) | 200 / N/A CFM | Unpublished | 5.3 CFM/W | 6 in. diameter |
| [**Delta VDBFRS200HT**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200ht/) | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| [**Delta VDBFRS200HT-P**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200ht-p/) | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| [**Broan FIN-180B**](https://siematic-charleston.com/ventilation-fans/broan-fin-180b/) | 180 / N/A CFM | Unpublished | 6.8 CFM/W | 6 in. diameter |

## Will Delta Pro300 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Delta Pro300 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Delta Pro300 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Delta Pro300 for residential use.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 221 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Ideal fit:** Bathroom floor <= 271 sq ft with 8-ft ceilings (241 sq ft at 9-ft height)
- **Primary match:** Exterior run uses smooth rigid metal matched to 6 in. diameter

## What key rules and numbers govern Delta Pro300?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Delta Pro300.

### Does Delta Pro300 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Delta Pro300 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Delta Pro300 undersized or poorly matched for a bath renovation?

Skip Delta Pro300 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Delta Pro300 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Delta Pro300 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.

### How does Delta Pro300 sound output compare to noisy contractor-grade fans?

Rated at 2.0 sones, Delta Pro300 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Delta Pro300?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Delta Pro300 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta Pro300's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Delta Pro300?

Delta Pro300 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Delta Pro300's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta Pro300's safe coverage footprint from 50 sq ft to 44 sq ft.

## Which guides and calculators connect next to Delta Pro300?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Delta Pro300.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Panasonic FV-30VQ3 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-30vq3/)
- [Zephyr AK8400BS-ES Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/zephyr-ak8400bs-es/)
- [Delta SLM70 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-slm70/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
